Heating & Cooling Load Screening Calculator
Estimate whole-house heating and cooling loads from envelope areas and U-values — a screening check against a contractor's figure.
Computed in your browser — nothing you enter is uploaded. Figures are presented in United States units and terminology, and each formula’s basis is cited under regulatory standards below.
Last verified 2026-08-26 · v1.0.0
Design heat loss
5,710 W
Steady-state whole-house loss. Sound as a screening figure and as a check on a quote; not a substitute for a room-by-room calculation, which is what sizes emitters.
- Fabric loss
- 4321.11 W
- Ventilation loss
- 1386.05 W
- Kilowatts
- 5.71 kW
- BTU/h
- 19473.64 BTU/h
- Ventilation as a share of the total
- 24.29 %
Running these inputs gives 5707 W as the design heat loss. Fabric loss carries the most weight in this calculation, at 4321 W. Expect some drift against the real job; the calculation is solid but conditions on site are not. Currently reading for United States — pick a different market above and the figures re-cast accordingly.
Add the equipment this sizes
This result is a specification — 5,710 W — not a quantity. Put the thing it sizes into your project: how many, what you call it, and your supplier’s price.
Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Regulatory standards & verification citations
- Steady-state fabric heat loss: Q = Σ(U × A × ΔT), the basis of every load method including ACCA Manual J and CIBSE Guide A
- Ventilation heat loss: Q = 0.33 × n × V × ΔT (W), CIBSE Guide A — 0.33 Wh/m³K is the volumetric heat capacity of air
- ACCA Manual J (8th ed.) for the full room-by-room procedure this approximates