Commercial ADA Accessible Ramp Length & Landing Calculator
Calculate the total horizontal length and number of intermediate landings needed for a permanent ADA-compliant accessible ramp.
Computed in your browser — nothing you enter is uploaded. Figures are presented in United States units and terminology, and each formula’s basis is cited under regulatory standards below.
Last verified 2026-08-26 · v1.0.0
Total ramp horizontal length
53 ft
This restates the fixed ADA 2010 Standards ramp geometry requirements (1:12 max slope, 30in max rise per run, 60in min landing length) for total horizontal length planning — it does not check ramp width, cross slope (max 1:48), edge protection, surface requirements, or handrail specifications (see the companion handrail extension calculator), all of which are separately required for full compliance.
- Number of ramp runs
- 2 runs
- Intermediate landings required
- 1 landings
Code thresholds this tool can check — United States
Each check below names the body that published the limit it uses. Switching market re-runs them. This is not a code review and has no official standing.
These checks cover only the specific numeric limits listed below. They are not a complete code review: fire separation, egress, structural capacity and accessibility provisions are outside their scope, and only the handful of local amendments offered in the selector are modelled — your municipality may have others. Passing every check here does not make a design compliant. Final approval rests with your local building authority.
WITHIN LIMIT — Maximum running slope 1:12; maximum rise 30 in (762 mm) per run.
Rise of 48 in exceeds 30 in, so 1 intermediate landing(s) are mandatory — they are included in the length above.
US Access Board · 2010 ADA Standards §405.2 / §405.6 · 2010 ADA Standards §405.6
For the dimensions entered, expect a total ramp horizontal length of 53 ft. Set for United States. The market selector changes the units and the trade terminology; any standard behind the formula is cited under sources.
Estimated cost — your price
This site holds no price list for this material — local prices vary too much to publish honestly. Enter your supplier's price and the result is costed with it.
Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Regulatory standards & verification citations
- Per the ADA 2010 Standards for Accessible Design (verified against regulatory text/mirrors this session): maximum running slope is 1:12 (Section 405.2); maximum rise for a single ramp run before a landing is required is 30 inches / 0.762m (Section 405.6); ramp handrails must extend 12 inches / 0.3048m minimum beyond the top and bottom of each run (Section 505.10.3, verified verbatim: 'Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs'). Minimum landing length is commonly cited as 60 inches / 1.524m (Section 405.7) — this specific figure was not independently re-verified against primary text this session (the source that confirmed the other figures did not include it), but is the standard, uncontested figure used throughout accessibility design references.