Stair Rise & Run Calculator
Calculate the number of risers and steps, and check riser/tread compliance against IRC or UK building code, for a staircase of a given total rise.
Computed in your browser — nothing you enter is uploaded. Figures are presented in United States units and terminology, and each formula’s basis is cited under regulatory standards below.
Last verified 2026-08-26 · v1.1.0
Number of risers needed
14 risers
PRELIMINARY CODE COMPLIANT — passes US IRC 2024: riser height and planned tread depth both meet the code minimums checked here. This covers riser height and tread depth only — headroom, handrail, and guard requirements must be checked separately.
- Actual riser height
- 7.71 in
- Number of treads (steps)
- 13 treads
- Recommended tread depth (comfort formula)
- 9.57 in
- Code max riser height (US IRC 2024)
- 7.75 in
- Code min tread depth (US IRC 2024)
- 10 in
Code thresholds this tool can check — United States
Each check below names the body that published the limit it uses. Switching market re-runs them. This is not a code review and has no official standing.
These checks cover only the specific numeric limits listed below. They are not a complete code review: fire separation, egress, structural capacity and accessibility provisions are outside their scope, and only the handful of local amendments offered in the selector are modelled — your municipality may have others. Passing every check here does not make a design compliant. Final approval rests with your local building authority.
WITHIN LIMIT — Maximum riser height 7.75 in (197 mm).
Riser height 7.71 in is within the 7.75 in IRC maximum.
ICC · IRC 2024 §R311.7.5.1
WITHIN LIMIT — Minimum tread depth 10 in (254 mm).
Tread depth 10.00 in meets the 10 in IRC minimum.
ICC · IRC 2024 §R311.7.5.2
IRC 2024 also specifies handrail height (34-38 in), minimum headroom (6 ft 8 in), and guard requirements for open sides — none of which this calculator checks, so confirm those separately with your local building department.
Add the equipment this sizes
This result is a specification — 14 risers — not a quantity. Put the thing it sizes into your project: how many, what you call it, and your supplier’s price.
Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Regulatory standards & verification citations
- Comfortable stair proportion rule of thumb: 2 x riser height + tread depth = 24-25 inches; most residential codes target a 7-7.75 in riser height
- US: IRC 2024 R311.7.5 — maximum riser height 7.75 in, minimum tread depth (going) 10 in
- UK: Approved Document K — maximum rise 220 mm, minimum going 220 mm for a private stair