ERV/HRV Sizing Calculator
Estimate the required continuous ventilation rate (CFM) for a whole-house ERV or HRV, per the ASHRAE 62.2 formula.
Computed in your browser — nothing you enter is uploaded. Figures are presented in United States units and terminology, and each formula’s basis is cited under regulatory standards below.
Last verified 2026-08-26 · v1.0.0
Required continuous ventilation rate
78.3 CFM (continuous)
This is the standard ASHRAE 62.2 formula for continuous whole-house mechanical ventilation — actual equipment selection should also account for your specific ERV/HRV unit's rated efficiency and any local code amendments to the base ASHRAE formula.
- House area
- 1610 sq ft
With the figures above, the required continuous ventilation rate comes to 78.3 CFM (continuous). This is presented for United States. Building in another market? Change the selector above and the units and terminology follow.
Add the equipment this sizes
This result is a specification — 78.3 CFM (continuous) — not a quantity. Put the thing it sizes into your project: how many, what you call it, and your supplier’s price.
Presented in US customary units and US trade terminology. Where a formula follows a published standard, that standard and its edition are cited beside it on this page; where none governs, the page says so. Local amendments override model codes — verify against the code in force where you build.
Regulatory standards & verification citations
- ASHRAE 62.2 whole-house mechanical ventilation formula: required CFM = 0.03 x floor area (sq ft) + 7.5 x (number of bedrooms + 1)