# National Fuel Gas Code (NFPA 54)

> The National Fuel Gas Code, published jointly by the NFPA and the American Gas Association and carrying the dual designation ANSI Z223.1 — one document…

Page: https://craftquantities.com/standards/nfpa/nfpa-54/ (standards page). This is the page's Markdown copy; the HTML page is the canonical version.

Published by National Fire Protection Association (NFPA) · written for United States

[nfpa.org](https://www.nfpa.org/) · checked 2026-09-23

Citing it here is not conformity with it, and this site holds no copy of its text.

- 3 Calculators cite it
- 1 Sections cited
- 3 Editions listed

## What it governs

The National Fuel Gas Code, published jointly by the NFPA and the American Gas Association and carrying the dual designation ANSI Z223.1 — one document with two numbers, which is why the same clause is cited both ways in the literature. Its subject runs from the point of delivery to the appliance connection: piping materials and sizing, shutoffs and regulators, the air a burner needs, and the route the products of combustion take out of the building.

A jurisdiction adopting it will not also be enforcing the IFGC, so a clause number quoted from the wrong one of the two is unarguable in an inspection even where the requirement behind it is identical. Its venting chapter is the part least safe to reason about from first principles.

Vent sizing is a lookup against a table built from appliance input, vent height and connector rise, and a vent that is too large cools the flue gases below their dew point exactly as surely as one that is too small fails to draw. Where a listed appliance arrives with its own installation instructions, those instructions govern the installation and this document steps back — which is the boundary most often crossed by somebody applying a table to an appliance the table was never drawn for.

Obtained from National Fire Protection Association. [What NFPA publishes](https://craftquantities.com/standards/#nfpa)

## Editions

Published: 2024, 2021, 2018. A new edition every three years.

**Adoption is not verified for your jurisdiction.** A model document binds only where an authority adopted it, usually some editions behind and amended locally. Citing a clause is not conformance. No part of the text is reproduced here.

## 3 calculators cite it

- [Appliance Combustion Air Free Area Calculator (Indoor Air Method)](https://craftquantities.com/calculators/materials-quantities/combustion-air-free-area-calculator/)
- [Fuel Gas Pipe Capacity Calculator](https://craftquantities.com/calculators/materials-quantities/gas-pipe-capacity-calculator/)
- [Gas Pipe Sizing Calculator (Longest-Length Method)6.2](https://craftquantities.com/calculators/plumbing-hvac/gas-pipe-sizing-calculator/)

**Cite this page**

[Every standard this site cites](https://craftquantities.com/standards/)

---
Source: https://craftquantities.com/standards/nfpa/nfpa-54/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.
