# A two-storey concrete block townhouse on a narrow lot: the material list

> A 12 × 7 m (39 × 23 ft) two-storey townhouse with concrete block walls on both floors, bond beams at each level, a strip footing and a shingle roof.

Page: https://craftquantities.com/house-estimator/two-storey-block-townhouse/ (House Estimator). This is the page's Markdown copy; the HTML page is the canonical version.

Two floors of block on an urban lot, where every pallet has to be lifted in from the street.

39' 0" × 23' 0", two storeys, 38 rows to buy (US customary) / 12.00 m × 7.00 m, two storeys, 38 rows to buy (metric)

![A two-storey concrete block townhouse on a narrow lot: isometric of the house, drawn from its own figures](https://craftquantities.com/work-pictures/house/two-storey-block-townhouse/iso-imperial.svg) (US customary) / ![A two-storey concrete block townhouse on a narrow lot: isometric of the house, drawn from its own figures](https://craftquantities.com/work-pictures/house/two-storey-block-townhouse/iso-metric.svg) (metric)

_Isometric, drawn from this house’s own drawing._

## Infill on a tight street

A gap between two older houses on a city street is often too narrow for a timber frame crew to lay out panels and too valuable to leave empty. A block shell suits it: the walls go up course by course from a single scaffold, the material arrives on pallets a lorry can crane over the pavement, and the finished wall resists fire and sound from the neighbours better than a light frame does without extra layers.

The house is 12 m (39 ft) deep and 7 m (23 ft) across, two storeys of 2.8 m (9 ft 2 in), with two partitions on each floor running the short way to make front, middle and back rooms.

## Two storeys of block, counted storey by storey

Each floor's walls are their own group in the list, so the block, grout, bond-beam and rebar rows appear once for the ground floor and once for the upper floor. That matches how the work is called off: the first lift of block to the first floor bond beam, then the floor goes on, then the second lift. Each storey's bond beam runs the full length of its walls, over the openings as well, while the stretcher rows take the doors and windows off at the height they actually occupy.

The control joint row works wall by wall: a joint every twice the wall's height, capped at the takeoff's limit, along each straight run. Joints at changes of height and beside openings are extra and come from the masonry drawings.

## Roof and foundation

A 6 in 12 shingle roof spans the 7 m width from eave to eave, with short 300 mm (about 12 in) eaves to stay inside the lot line. No ice-dam strip: the count is 0. The strip footing under the outside walls is 600 mm (2 ft) wide in a trench 0.9 m (3 ft) deep; a party wall on the boundary would need a footing designed with the neighbour's in mind, which this page does not attempt.

## Outside this list

The upper floor structure, the stair, the render or brick slip on the street face, lintels, and the vertical reinforcement and grouted cells a two-storey block wall may need are design matters for the engineer and are not counted. Craneage and pavement licences are the job's logistics, not quantities.

[Describe your own house in the estimator](https://craftquantities.com/house-estimator/): the same six steps, its elevations and 3D model, and the list as a workbench.

_US customary:_

100%

_Ground floor, to scale._

100%

_Upper floor, to scale._

_metric:_

100%

_Ground floor, to scale._

100%

_Upper floor, to scale._

![A two-storey concrete block townhouse on a narrow lot: front elevation, to scale](https://craftquantities.com/work-pictures/house/two-storey-block-townhouse/elevation-imperial.svg) (US customary) / ![A two-storey concrete block townhouse on a narrow lot: front elevation, to scale](https://craftquantities.com/work-pictures/house/two-storey-block-townhouse/elevation-metric.svg) (metric)

_Front elevation, to scale, from the canvas’s own view of this house; its side elevations, sections and 3D model open with it in the canvas._

## Everything to buy

Quantities to order, with each calculator’s own waste. Your own rates go on the lines in My Project.

_US customary:_

**Foundation and floor**

| Material, and where | Quantity |
|---|---|
| Continuous Footing / Grade Beam Volume FT-1, Ground floor | 9.24 yd³ |
| Trench Excavation & Backfill Volume FT-1, Ground floor | 14.05 yd³ |
| Rebar FT-1, Ground floor | 24 x 20 ft sticks |
| Concrete SL-1, Ground floor | 12.23 yd³ |
| Rebar SL-1, Ground floor | 71 x 20 ft sticks |
| Concrete Formwork SL-1, Ground floor | 18 x 8 ft boards |

**Walls**

| Material, and where | Quantity |
|---|---|
| Cavity Wall Weep Hole Spacing EW-1, Ground floor, 4 walls | 63 weep holes |
| Concrete CMU Block Counter & Grout Infill EW-1, Ground floor, 4 walls | 926 blocks |
| CMU Bond Beam Block Count EW-1, Ground floor, 4 walls | 184 bond beam blocks |
| Masonry Bond Beam Rebar EW-1, Ground floor, 4 walls | 186.46 lb |
| Masonry Control Joint Spacing EW-1, Ground floor, 4 walls | 6 control joints |
| Framing Stud IW-1, Ground floor, 2 walls | 58 studs |
| Outlet Spacing IW-1, Ground floor, 2 walls | 4 outlets (minimum) |
| Drywall Joint Compound IW-1, Ground floor, 2 walls | 2 x 4.5 gal boxes |
| Cavity Wall Weep Hole Spacing EW-1, Upper floor, 4 walls | 63 weep holes |
| Concrete CMU Block Counter & Grout Infill EW-1, Upper floor, 4 walls | 976 blocks |
| CMU Bond Beam Block Count EW-1, Upper floor, 4 walls | 184 bond beam blocks |
| Masonry Bond Beam Rebar EW-1, Upper floor, 4 walls | 186.46 lb |
| Masonry Control Joint Spacing EW-1, Upper floor, 4 walls | 6 control joints |
| Framing Stud IW-1, Upper floor, 2 walls | 58 studs |
| Outlet Spacing IW-1, Upper floor, 2 walls | 4 outlets (minimum) |
| Drywall Joint Compound IW-1, Upper floor, 2 walls | 2 x 4.5 gal boxes |

**Doors and windows**

| Material, and where | Quantity |
|---|---|
| Flashing tape round the opening, for a timber-framed wall DR-1, Ground floor, 2 openings | 57.2 ft |
| Architrave (casing) inside, two legs and a head DR-1, Ground floor, 2 openings | 37.4 linear ft |
| Mastic (caulk) round the frame, outside and inside DR-1, Ground floor, 2 openings | 4 tubes |
| Paint for the door and frame, both faces: undercoat and gloss DR-1, Ground floor, 2 openings | 0.5269 gal |
| Window Opening Flashing Membrane WN-1, Ground floor, 6 openings | 154.01 ft |
| Door & Window Casing WN-1, Ground floor, 6 openings | 112.21 linear ft |
| Window Opening Flashing Membrane WN-1, Upper floor, 6 openings | 154.01 ft |
| Door & Window Casing WN-1, Upper floor, 6 openings | 112.21 linear ft |
| Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing | 8 each |
| Outside doors, 914 × 2134 mm (36 × 84 in)counted on the drawing | 2 each |
| Windows, 1067 × 1524 mm (42 × 60 in)counted on the drawing | 12 each |

**Roof**

| Material, and where | Quantity |
|---|---|
| Roofing Shingle RF-1, Upper floor | 12.37 squares |
| Roofing Underlayment RF-1, Upper floor | 2 rolls |
| Roof Ridge Cap RF-1, Upper floor | 2 bundles |
| Ridge Vent Linear Footage RF-1, Upper floor | 42.31 ft |
| Roof trusses RF-1, Upper floor | 21 trusses |

_metric:_

**Foundation and floor**

| Material, and where | Quantity |
|---|---|
| Continuous Footing / Grade Beam Volume FT-1, Ground floor | 7.03 m³ |
| Trench Excavation & Backfill Volume FT-1, Ground floor | 10.27 m³ (loose) |
| Rebar FT-1, Ground floor | 12 x 12 m sticks |
| Concrete SL-1, Ground floor | 9.24 m³ |
| Rebar SL-1, Ground floor | 37 x 12 m sticks |
| Concrete Formwork SL-1, Ground floor | 18 x 2.4 m boards |

**Walls**

| Material, and where | Quantity |
|---|---|
| Cavity Wall Weep Hole Spacing EW-1, Ground floor, 4 walls | 64 weep holes |
| Concrete CMU Block Counter & Grout Infill EW-1, Ground floor, 4 walls | 774 blocks |
| CMU Bond Beam Block Count EW-1, Ground floor, 4 walls | 166 bond beam blocks |
| Masonry Bond Beam Rebar EW-1, Ground floor, 4 walls | 85.05 kg |
| Masonry Control Joint Spacing EW-1, Ground floor, 4 walls | 6 control joints |
| Framing Stud IW-1, Ground floor, 2 walls | 58 studs |
| Outlet Spacing IW-1, Ground floor, 2 walls | 4 outlets (minimum) |
| Drywall Joint Compound IW-1, Ground floor, 2 walls | 40.51 kg |
| Cavity Wall Weep Hole Spacing EW-1, Upper floor, 4 walls | 64 weep holes |
| Concrete CMU Block Counter & Grout Infill EW-1, Upper floor, 4 walls | 814 blocks |
| CMU Bond Beam Block Count EW-1, Upper floor, 4 walls | 166 bond beam blocks |
| Masonry Bond Beam Rebar EW-1, Upper floor, 4 walls | 85.05 kg |
| Masonry Control Joint Spacing EW-1, Upper floor, 4 walls | 6 control joints |
| Framing Stud IW-1, Upper floor, 2 walls | 58 studs |
| Outlet Spacing IW-1, Upper floor, 2 walls | 4 outlets (minimum) |
| Drywall Joint Compound IW-1, Upper floor, 2 walls | 40.51 kg |

**Doors and windows**

| Material, and where | Quantity |
|---|---|
| Flashing tape round the opening, for a timber-framed wall DR-1, Ground floor, 2 openings | 17.25 m |
| Architrave (casing) inside, two legs and a head DR-1, Ground floor, 2 openings | 11.26 m |
| Mastic (caulk) round the frame, outside and inside DR-1, Ground floor, 2 openings | 4 tubes |
| Paint for the door and frame, both faces: undercoat and gloss DR-1, Ground floor, 2 openings | 1.93 L |
| Window Opening Flashing Membrane WN-1, Ground floor, 6 openings | 45.54 m |
| Door & Window Casing WN-1, Ground floor, 6 openings | 33 m |
| Window Opening Flashing Membrane WN-1, Upper floor, 6 openings | 45.54 m |
| Door & Window Casing WN-1, Upper floor, 6 openings | 33 m |
| Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing | 8 each |
| Outside doors, 920 × 2100 mm (36 1/4 × 82 3/4 in)counted on the drawing | 2 each |
| Windows, 1000 × 1500 mm (39 1/4 × 59 in)counted on the drawing | 12 each |

**Roof**

| Material, and where | Quantity |
|---|---|
| Roofing Shingle RF-1, Upper floor | 115.9 m² |
| Roofing Underlayment RF-1, Upper floor | 2 rolls |
| Roof Ridge Cap RF-1, Upper floor | 2 bundles |
| Ridge Vent Linear Footage RF-1, Upper floor | 13.02 m |
| Roof trusses RF-1, Upper floor | 21 trusses |

## What changes if

_US customary:_

### With brick instead of block

- Continuous Footing / Grade Beam Volume: 9.24 yd³ → 9.34 yd³
- Trench Excavation & Backfill Volume: 14.05 yd³ → 17.67 yd³
- Concrete CMU Block Counter & Grout Infill: 926 blocks → none
- CMU Bond Beam Block Count: 184 bond beam blocks → none
- Masonry Bond Beam Rebar: 186.46 lb → none
- Masonry Control Joint Spacing: 6 control joints → none
- Framing Stud: 58 studs → 60 studs
- Concrete CMU Block Counter & Grout Infill: 976 blocks → none
- CMU Bond Beam Block Count: 184 bond beam blocks → none
- Masonry Bond Beam Rebar: 186.46 lb → none
- Masonry Control Joint Spacing: 6 control joints → none
- Framing Stud: 58 studs → 60 studs
- Brick: none → 7,309 bricks
- Brick Veneer Anchor Spacing: none → 420 anchors
- Brick Movement Joint Spacing: none → 6 movement joints
- Brick: none → 7,625 bricks
- Brick Veneer Anchor Spacing: none → 440 anchors
- Brick Movement Joint Spacing: none → 6 movement joints

### With a timber-framed exterior wall instead

- Continuous Footing / Grade Beam Volume: 9.24 yd³ → 9.34 yd³
- Trench Excavation & Backfill Volume: 14.05 yd³ → 17.67 yd³
- Cavity Wall Weep Hole Spacing: 63 weep holes → none
- Concrete CMU Block Counter & Grout Infill: 926 blocks → none
- CMU Bond Beam Block Count: 184 bond beam blocks → none
- Masonry Bond Beam Rebar: 186.46 lb → none
- Masonry Control Joint Spacing: 6 control joints → none
- Framing Stud: 58 studs → 60 studs
- Cavity Wall Weep Hole Spacing: 63 weep holes → none
- Concrete CMU Block Counter & Grout Infill: 976 blocks → none
- CMU Bond Beam Block Count: 184 bond beam blocks → none
- Masonry Bond Beam Rebar: 186.46 lb → none
- Masonry Control Joint Spacing: 6 control joints → none
- Framing Stud: 58 studs → 60 studs
- Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centres: none → 148 studs
- Plates, headers, sills, cripples, corner and junction studs: none → 544.36 ft
- Fibreglass batts, 3 1/2 in (89 mm), for 2×4 cavities: none → 11 packages
- Wall sheathing, OSB 7/16 in (11 mm): none → 34 sheets (4x8 ft)
- House Wrap: none → 1 roll
- Vinyl siding: none → 10.66 squares
- Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centres: none → 140 studs
- Plates, headers, sills, cripples, corner and junction studs: none → 539.78 ft
- Fibreglass batts, 3 1/2 in (89 mm), for 2×4 cavities: none → 11 packages
- Wall sheathing, OSB 7/16 in (11 mm): none → 35 sheets (4x8 ft)
- House Wrap: none → 1 roll
- Vinyl siding: none → 11.12 squares

_metric:_

### With brick instead of block

- Continuous Footing / Grade Beam Volume: 7.03 m³ → 7.11 m³
- Trench Excavation & Backfill Volume: 10.27 m³ (loose) → 12.97 m³ (loose)
- Concrete CMU Block Counter & Grout Infill: 774 blocks → none
- CMU Bond Beam Block Count: 166 bond beam blocks → none
- Masonry Bond Beam Rebar: 85.05 kg → none
- Masonry Control Joint Spacing: 6 control joints → none
- Drywall Joint Compound: 40.51 kg → 41.99 kg
- Concrete CMU Block Counter & Grout Infill: 814 blocks → none
- CMU Bond Beam Block Count: 166 bond beam blocks → none
- Masonry Bond Beam Rebar: 85.05 kg → none
- Masonry Control Joint Spacing: 6 control joints → none
- Drywall Joint Compound: 40.51 kg → 41.99 kg
- Brick: none → 6,098 bricks
- Brick Veneer Anchor Spacing: none → 473 anchors
- Brick Movement Joint Spacing: none → 6 movement joints
- Brick: none → 6,350 bricks
- Brick Veneer Anchor Spacing: none → 484 anchors
- Brick Movement Joint Spacing: none → 6 movement joints

### With a timber-framed exterior wall instead

- Continuous Footing / Grade Beam Volume: 7.03 m³ → 7.11 m³
- Trench Excavation & Backfill Volume: 10.27 m³ (loose) → 12.97 m³ (loose)
- Cavity Wall Weep Hole Spacing: 64 weep holes → none
- Concrete CMU Block Counter & Grout Infill: 774 blocks → none
- CMU Bond Beam Block Count: 166 bond beam blocks → none
- Masonry Bond Beam Rebar: 85.05 kg → none
- Masonry Control Joint Spacing: 6 control joints → none
- Drywall Joint Compound: 40.51 kg → 41.99 kg
- Cavity Wall Weep Hole Spacing: 64 weep holes → none
- Concrete CMU Block Counter & Grout Infill: 814 blocks → none
- CMU Bond Beam Block Count: 166 bond beam blocks → none
- Masonry Bond Beam Rebar: 85.05 kg → none
- Masonry Control Joint Spacing: 6 control joints → none
- Drywall Joint Compound: 40.51 kg → 41.99 kg
- Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centres: none → 144 studs
- Plates, headers, sills, cripples, corner and junction studs: none → 168.11 m
- Fibreglass batts, 3 1/2 in (89 mm), for 2×4 cavities: none → 11 packages
- Wall sheathing, OSB 7/16 in (11 mm): none → 35 sheets (2440x1220 mm)
- House Wrap: none → 1 roll
- Vinyl siding: none → 102.89 m²
- Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centres: none → 136 studs
- Plates, headers, sills, cripples, corner and junction studs: none → 166.35 m
- Fibreglass batts, 3 1/2 in (89 mm), for 2×4 cavities: none → 12 packages
- Wall sheathing, OSB 7/16 in (11 mm): none → 36 sheets (2440x1220 mm)
- House Wrap: none → 1 roll
- Vinyl siding: none → 107.14 m²

This page counts materials and does not check strength. Every figure nobody typed is listed on the [House Estimator](https://craftquantities.com/house-estimator/), where this house can be changed.

## Other example houses

- [A ranch for a cold winter](https://craftquantities.com/house-estimator/cold-climate-ranch/)
- [A two-storey house in advanced framing](https://craftquantities.com/house-estimator/two-storey-advanced-framing/)
- [A concrete block house for a hot coast](https://craftquantities.com/house-estimator/concrete-block-house/)
- [A small mountain cabin](https://craftquantities.com/house-estimator/mountain-cabin/)
- [A British timber-frame house](https://craftquantities.com/house-estimator/uk-timber-frame-house/)

---
Source: https://craftquantities.com/house-estimator/two-storey-block-townhouse/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.