# A two-storey family house in advanced framing: the full material list

> A 10 × 8 m (33 × 26 ft) two-storey house framed in 2×6 at 24 in, with mineral wool, a poly vapour retarder, plywood and fibre-cement siding.

Page: https://craftquantities.com/house-estimator/two-storey-advanced-framing/ (House Estimator). This is the page's Markdown copy; the HTML page is the canonical version.

Fewer, deeper studs and more insulation: the frame that turns the same timber into a warmer wall.

33' 0" × 26' 0", two storeys, 43 rows to buy (US customary) / 10.00 m × 8.00 m, two storeys, 43 rows to buy (metric)

![A two-storey family house in advanced framing: isometric of the house, drawn from its own figures](https://craftquantities.com/work-pictures/house/two-storey-advanced-framing/iso-imperial.svg) (US customary) / ![A two-storey family house in advanced framing: isometric of the house, drawn from its own figures](https://craftquantities.com/work-pictures/house/two-storey-advanced-framing/iso-metric.svg) (metric)

_Isometric, drawn from this house’s own drawing._

## A compact footprint stacked twice

A narrow suburban lot rewards building up rather than out. This plan puts the living rooms downstairs and three bedrooms above, on a footprint small enough that one slab and one perimeter footing carry both floors. Every exterior wall appears twice in the drawing, once per storey, and the estimator counts each storey's studs and sheathing on its own level so you can see what goes up in each lift.

The storeys are 2.6 m (8 ft 6 in) floor to floor, which leaves room for a floor structure between them; the floor joists themselves are not a row here, because the site has no calculator that counts joists from a span and a spacing yet.

## What advanced framing changes

Two-by-six studs at 24 inch centres are the core of what builders call optimum value engineering. The deeper cavity holds 5 1/2 in (140 mm) of mineral wool instead of 3 1/2, and wider spacing means fewer studs bridging the insulation. The wall drawn here is thicker than a 2×4 wall by the difference in stud depth, and the plan shows it.

The saving is not automatic. Studs at 24 in have to land under the joists or trusses above, sheathing and siding must both be rated for that spacing, and window openings want their headers designed rather than guessed. Compare the stud row with the swap below to see what the wider spacing actually saves on this house.

## The weather side

Plywood sheathing is chosen for its nail holding and its tolerance of a wet week before the wrap goes on. Fibre-cement lap siding goes over it; its row carries the higher cutting waste that brittle planks produce. A polyethylene membrane sits on the warm side of the mineral wool, the arrangement many cold-climate codes describe, with the openings deducted from its inside face area.

## Checks before the order

An 8 in 12 roof over a two-storey house is a long way up: arrange scaffolding or a lift with your own supplier, because no row here measures access. And read the outside door count: two doors on the ground floor, each with its flashing, casing, sealant and paint rows, are counted from their own size, 920 × 2100 mm (36 × 84 in).

[Describe your own house in the estimator](https://craftquantities.com/house-estimator/): the same six steps, its elevations and 3D model, and the list as a workbench.

_US customary:_

100%

_Ground floor, to scale._

100%

_Upper floor, to scale._

_metric:_

100%

_Ground floor, to scale._

100%

_Upper floor, to scale._

![A two-storey family house in advanced framing: front elevation, to scale](https://craftquantities.com/work-pictures/house/two-storey-advanced-framing/elevation-imperial.svg) (US customary) / ![A two-storey family house in advanced framing: front elevation, to scale](https://craftquantities.com/work-pictures/house/two-storey-advanced-framing/elevation-metric.svg) (metric)

_Front elevation, to scale, from the canvas’s own view of this house; its side elevations, sections and 3D model open with it in the canvas._

## Everything to buy

Quantities to order, with each calculator’s own waste. Your own rates go on the lines in My Project.

_US customary:_

**Foundation and floor**

| Material, and where | Quantity |
|---|---|
| Continuous Footing / Grade Beam Volume FT-1, Ground floor | 8.83 yd³ |
| Trench Excavation & Backfill Volume FT-1, Ground floor | 18.73 yd³ |
| Rebar FT-1, Ground floor | 23 x 20 ft sticks |
| Concrete SL-1, Ground floor | 11.7 yd³ |
| Rebar SL-1, Ground floor | 68 x 20 ft sticks |
| Concrete Formwork SL-1, Ground floor | 17 x 8 ft boards |

**Walls**

| Material, and where | Quantity |
|---|---|
| Studs, 2×6 (38 × 140 mm) at 24 in (600 mm) centres EW-1, Ground floor, 4 walls | 111 studs |
| Plates, headers, sills, cripples, corner and junction studs EW-1, Ground floor, 4 walls | 495.67 ft |
| Mineral wool batts, 5 1/2 in (140 mm), for 2×6 cavities EW-1, Ground floor, 4 walls | 17 packages |
| Vapour retarder, 6-mil (0.15 mm) polyethylene EW-1, Ground floor, 4 walls | 1 roll |
| Wall sheathing, plywood 1/2 in (12 mm)EW-1, Ground floor, 4 walls | 30 sheets (4x8 ft) |
| House Wrap EW-1, Ground floor, 4 walls | 1 roll |
| Fibre-cement lap siding EW-1, Ground floor, 4 walls | 952.87 sq ft |
| Framing Stud IW-1, Ground floor, 2 walls | 69 studs |
| Outlet Spacing IW-1, Ground floor, 2 walls | 6 outlets (minimum) |
| Drywall Joint Compound IW-1, Ground floor, 2 walls | 2 x 4.5 gal boxes |
| Studs, 2×6 (38 × 140 mm) at 24 in (600 mm) centres EW-1, Upper floor, 4 walls | 102 studs |
| Plates, headers, sills, cripples, corner and junction studs EW-1, Upper floor, 4 walls | 494.37 ft |
| Mineral wool batts, 5 1/2 in (140 mm), for 2×6 cavities EW-1, Upper floor, 4 walls | 18 packages |
| Vapour retarder, 6-mil (0.15 mm) polyethylene EW-1, Upper floor, 4 walls | 1 roll |
| Wall sheathing, plywood 1/2 in (12 mm)EW-1, Upper floor, 4 walls | 31 sheets (4x8 ft) |
| House Wrap EW-1, Upper floor, 4 walls | 1 roll |
| Fibre-cement lap siding EW-1, Upper floor, 4 walls | 999.9 sq ft |
| Framing Stud IW-1, Upper floor, 2 walls | 69 studs |
| Outlet Spacing IW-1, Upper floor, 2 walls | 6 outlets (minimum) |
| Drywall Joint Compound IW-1, Upper floor, 2 walls | 2 x 4.5 gal boxes |

**Doors and windows**

| Material, and where | Quantity |
|---|---|
| Flashing tape round the opening, for a timber-framed wall DR-1, Ground floor, 2 openings | 57.2 ft |
| Architrave (casing) inside, two legs and a head DR-1, Ground floor, 2 openings | 37.4 linear ft |
| Mastic (caulk) round the frame, outside and inside DR-1, Ground floor, 2 openings | 4 tubes |
| Paint for the door and frame, both faces: undercoat and gloss DR-1, Ground floor, 2 openings | 0.5269 gal |
| Window Opening Flashing Membrane WN-1, Ground floor, 7 openings | 172 ft |
| Door & Window Casing WN-1, Ground floor, 7 openings | 123.23 linear ft |
| Window Opening Flashing Membrane WN-1, Upper floor, 7 openings | 172 ft |
| Door & Window Casing WN-1, Upper floor, 7 openings | 123.23 linear ft |
| Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing | 10 each |
| Outside doors, 914 × 2134 mm (36 × 84 in)counted on the drawing | 2 each |
| Windows, 1067 × 1372 mm (42 × 54 in)counted on the drawing | 14 each |

**Roof**

| Material, and where | Quantity |
|---|---|
| Roofing Shingle RF-1, Upper floor | 13.67 squares |
| Roofing Underlayment RF-1, Upper floor | 1 roll |
| Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining)RF-1, Upper floor | 342.72 sq ft |
| Roof Ridge Cap RF-1, Upper floor | 2 bundles |
| Ridge Vent Linear Footage RF-1, Upper floor | 37.45 ft |
| Roof trusses RF-1, Upper floor | 18 trusses |

_metric:_

**Foundation and floor**

| Material, and where | Quantity |
|---|---|
| Continuous Footing / Grade Beam Volume FT-1, Ground floor | 6.69 m³ |
| Trench Excavation & Backfill Volume FT-1, Ground floor | 12.76 m³ (loose) |
| Rebar FT-1, Ground floor | 12 x 12 m sticks |
| Concrete SL-1, Ground floor | 8.8 m³ |
| Rebar SL-1, Ground floor | 35 x 12 m sticks |
| Concrete Formwork SL-1, Ground floor | 17 x 2.4 m boards |

**Walls**

| Material, and where | Quantity |
|---|---|
| Studs, 2×6 (38 × 140 mm) at 24 in (600 mm) centres EW-1, Ground floor, 4 walls | 111 studs |
| Plates, headers, sills, cripples, corner and junction studs EW-1, Ground floor, 4 walls | 151.11 m |
| Mineral wool batts, 5 1/2 in (140 mm), for 2×6 cavities EW-1, Ground floor, 4 walls | 18 packages |
| Vapour retarder, 6-mil (0.15 mm) polyethylene EW-1, Ground floor, 4 walls | 1 roll |
| Wall sheathing, plywood 1/2 in (12 mm)EW-1, Ground floor, 4 walls | 30 sheets (2440x1220 mm) |
| House Wrap EW-1, Ground floor, 4 walls | 1 roll |
| Fibre-cement lap siding EW-1, Ground floor, 4 walls | 89.53 m² |
| Framing Stud IW-1, Ground floor, 2 walls | 69 studs |
| Outlet Spacing IW-1, Ground floor, 2 walls | 6 outlets (minimum) |
| Drywall Joint Compound IW-1, Ground floor, 2 walls | 42.44 kg |
| Studs, 2×6 (38 × 140 mm) at 24 in (600 mm) centres EW-1, Upper floor, 4 walls | 102 studs |
| Plates, headers, sills, cripples, corner and junction studs EW-1, Upper floor, 4 walls | 150.63 m |
| Mineral wool batts, 5 1/2 in (140 mm), for 2×6 cavities EW-1, Upper floor, 4 walls | 18 packages |
| Vapour retarder, 6-mil (0.15 mm) polyethylene EW-1, Upper floor, 4 walls | 1 roll |
| Wall sheathing, plywood 1/2 in (12 mm)EW-1, Upper floor, 4 walls | 31 sheets (2440x1220 mm) |
| House Wrap EW-1, Upper floor, 4 walls | 1 roll |
| Fibre-cement lap siding EW-1, Upper floor, 4 walls | 93.86 m² |
| Framing Stud IW-1, Upper floor, 2 walls | 69 studs |
| Outlet Spacing IW-1, Upper floor, 2 walls | 6 outlets (minimum) |
| Drywall Joint Compound IW-1, Upper floor, 2 walls | 42.44 kg |

**Doors and windows**

| Material, and where | Quantity |
|---|---|
| Flashing tape round the opening, for a timber-framed wall DR-1, Ground floor, 2 openings | 17.25 m |
| Architrave (casing) inside, two legs and a head DR-1, Ground floor, 2 openings | 11.26 m |
| Mastic (caulk) round the frame, outside and inside DR-1, Ground floor, 2 openings | 4 tubes |
| Paint for the door and frame, both faces: undercoat and gloss DR-1, Ground floor, 2 openings | 1.93 L |
| Window Opening Flashing Membrane WN-1, Ground floor, 7 openings | 51.59 m |
| Door & Window Casing WN-1, Ground floor, 7 openings | 36.96 m |
| Window Opening Flashing Membrane WN-1, Upper floor, 7 openings | 51.59 m |
| Door & Window Casing WN-1, Upper floor, 7 openings | 36.96 m |
| Interior doors, 800 × 2000 mm (31 1/2 × 78 3/4 in)counted on the drawing | 10 each |
| Outside doors, 920 × 2100 mm (36 1/4 × 82 3/4 in)counted on the drawing | 2 each |
| Windows, 1000 × 1400 mm (39 1/4 × 55 in)counted on the drawing | 14 each |

**Roof**

| Material, and where | Quantity |
|---|---|
| Roofing Shingle RF-1, Upper floor | 128.5 m² |
| Roofing Underlayment RF-1, Upper floor | 1 roll |
| Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining)RF-1, Upper floor | 32.75 m² |
| Roof Ridge Cap RF-1, Upper floor | 2 bundles |
| Ridge Vent Linear Footage RF-1, Upper floor | 11.34 m |
| Roof trusses RF-1, Upper floor | 18 trusses |

## What changes if

_US customary:_

### With the same walls in 2×4 at 16 in

- Continuous Footing / Grade Beam Volume: 8.83 yd³ → 8.88 yd³
- Trench Excavation & Backfill Volume: 18.73 yd³ → 20.93 yd³
- Studs, 2×6 (38 × 140 mm) at 24 in (600 mm) centres, now Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centres: 111 studs → 144 studs
- Plates, headers, sills, cripples, corner and junction studs: 495.67 ft → 522.7 ft
- Mineral wool batts, 5 1/2 in (140 mm), for 2×6 cavities, now Mineral wool batts, 3 1/2 in (89 mm), for 2×4 cavities: 17 packages → 18 packages
- Fibre-cement lap siding: 952.87 sq ft → 952.74 sq ft
- Studs, 2×6 (38 × 140 mm) at 24 in (600 mm) centres, now Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centres: 102 studs → 136 studs
- Plates, headers, sills, cripples, corner and junction studs: 494.37 ft → 520.12 ft
- Mineral wool batts, 5 1/2 in (140 mm), for 2×6 cavities, now Mineral wool batts, 3 1/2 in (89 mm), for 2×4 cavities: 18 packages → 19 packages
- Fibre-cement lap siding: 999.9 sq ft → 999.77 sq ft
- Roofing Underlayment: 1 roll → 2 rolls
- Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining): 342.72 sq ft → 328.38 sq ft

### With closed-cell spray foam in the cavities instead

- Mineral wool batts, 5 1/2 in (140 mm), for 2×6 cavities: 17 packages → none
- Vapour retarder, 6-mil (0.15 mm) polyethylene: 1 roll → none
- Mineral wool batts, 5 1/2 in (140 mm), for 2×6 cavities: 18 packages → none
- Vapour retarder, 6-mil (0.15 mm) polyethylene: 1 roll → none
- Closed-cell spray foam, full 2×6 cavity (5 1/2 in, 140 mm): none → 8 x 600 bd-ft kits
- Closed-cell spray foam, full 2×6 cavity (5 1/2 in, 140 mm): none → 8 x 600 bd-ft kits

_metric:_

### With the same walls in 2×4 at 16 in

- Continuous Footing / Grade Beam Volume: 6.69 m³ → 6.73 m³
- Trench Excavation & Backfill Volume: 12.76 m³ (loose) → 14.3 m³ (loose)
- Studs, 2×6 (38 × 140 mm) at 24 in (600 mm) centres, now Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centres: 111 studs → 144 studs
- Plates, headers, sills, cripples, corner and junction studs: 151.11 m → 159.64 m
- Mineral wool batts, 5 1/2 in (140 mm), for 2×6 cavities, now Mineral wool batts, 3 1/2 in (89 mm), for 2×4 cavities: 18 packages → 18 packages
- Fibre-cement lap siding: 89.53 m² → 89.52 m²
- Drywall Joint Compound: 42.44 kg → 43.14 kg
- Studs, 2×6 (38 × 140 mm) at 24 in (600 mm) centres, now Studs, 2×4 (38 × 89 mm) at 16 in (400 mm) centres: 102 studs → 136 studs
- Plates, headers, sills, cripples, corner and junction studs: 150.63 m → 158.68 m
- Mineral wool batts, 5 1/2 in (140 mm), for 2×6 cavities, now Mineral wool batts, 3 1/2 in (89 mm), for 2×4 cavities: 18 packages → 19 packages
- Fibre-cement lap siding: 93.86 m² → 93.84 m²
- Drywall Joint Compound: 42.44 kg → 43.14 kg
- Roofing Underlayment: 1 roll → 2 rolls
- Roof Eave Ice Dam Protection Membrane Footprint (and Valley Lining): 32.75 m² → 31.43 m²

### With closed-cell spray foam in the cavities instead

- Mineral wool batts, 5 1/2 in (140 mm), for 2×6 cavities: 18 packages → none
- Vapour retarder, 6-mil (0.15 mm) polyethylene: 1 roll → none
- Mineral wool batts, 5 1/2 in (140 mm), for 2×6 cavities: 18 packages → none
- Vapour retarder, 6-mil (0.15 mm) polyethylene: 1 roll → none
- Closed-cell spray foam, full 2×6 cavity (5 1/2 in, 140 mm): none → 10.56 m³
- Closed-cell spray foam, full 2×6 cavity (5 1/2 in, 140 mm): none → 11.1 m³

This page counts materials and does not check strength. Every figure nobody typed is listed on the [House Estimator](https://craftquantities.com/house-estimator/), where this house can be changed.

## Other example houses

- [A ranch for a cold winter](https://craftquantities.com/house-estimator/cold-climate-ranch/)
- [A concrete block house for a hot coast](https://craftquantities.com/house-estimator/concrete-block-house/)
- [A small mountain cabin](https://craftquantities.com/house-estimator/mountain-cabin/)
- [A British timber-frame house](https://craftquantities.com/house-estimator/uk-timber-frame-house/)
- [A two-storey block townhouse](https://craftquantities.com/house-estimator/two-storey-block-townhouse/)

---
Source: https://craftquantities.com/house-estimator/two-storey-advanced-framing/