# Sound insulation ratings

> United States and Canada: STC. United Kingdom and Australia: Rw. Single-figure numbers summarising how much sound a construction stops. They compress a…

Page: https://craftquantities.com/glossary/sound-rating/ (glossary concept). This is the page's Markdown copy; the HTML page is the canonical version.

Single-figure numbers summarising how much sound a construction stops. They compress a whole frequency curve into one value, and the rules for doing that differ by market — so the figures are not interchangeable.

- 4 Markets
- No Same thing everywhere
- 3 Calculators

## What it is called, by market

One concept, four markets. Where a name means something else locally, the card says so rather than leaving you to find out on site.

- ### United Kingdom

  Same word, different thing

  Rw

  also DnT,w, DnT,w + Ctr, L'nT,w, sound reduction index

  Rw is a LABORATORY figure for an element. DnT,w + Ctr is what Approved Document E requires and is measured in the FINISHED building, including flanking — so it is always lower than the lab number.
- ### Australia

  Close, not identical

  Rw

  also Rw + Ctr, Ln,w, weighted sound reduction index

  The ISO system as in the UK, with Rw + Ctr the regulated figure for separating walls and floors under the NCC.
- ### United States yours

  Same word, different thing

  STC

  also sound transmission class, OITC, IIC, FSTC

  STC is derived differently from Rw: a different frequency range and a different contour-fitting rule. The two are close for many constructions and not equal, and neither converts to the other by arithmetic.
- ### Canada

  Same word, different thing

  STC

  also ASTC, IIC, sound transmission class

  ASTC is the apparent STC measured in the FINISHED building including flanking, which is the Canadian counterpart of DnT,w and is the figure the code actually asks for.

## The governing standard, by market

- United Kingdom

  Approved Document E / BS EN ISO 717-1

  Resistance to the passage of sound including pre-completion testing, and the rating of airborne sound insulation in buildings.
- United States

  ASTM E90 / ASTM E413

  Laboratory measurement of airborne sound transmission loss, and the classification for rating sound insulation (STC).

## Calculators for this

Each works in either measurement system, and the terminology on the page follows whichever market you have selected.

- [Mass-Loaded Vinyl (MLV) Soundproofing Barrier Calculator](https://craftquantities.com/calculators/materials-quantities/mlv-soundproofing-calculator/)
- [Multi-Stud Wall Sound Transmission Class (STC) Estimator](https://craftquantities.com/calculators/materials-quantities/multi-stud-wall-stc-estimator/)
- [Acoustic Sealant Bead Volume Calculator](https://craftquantities.com/calculators/materials-quantities/acoustic-sealant-volume-calculator/)

## Frequently asked questions

**Can an STC figure be converted to an Rw?**

Not by arithmetic, and the fact that they usually land within a point or two of each other is what makes the assumption dangerous. Both compress a measured curve of sound reduction against frequency into one number by sliding a reference contour until the deviations meet a rule — but the contours differ, the frequency bands included differ, and the rules about how much deviation is allowed differ. For a simple partition the two often agree closely; for constructions with an unusual curve — a lightweight panel with a pronounced dip, a double-glazed unit, a resiliently mounted lining — they can diverge by several points. So a product tested to one system has to be quoted in that system, and a specification asking for Rw is not satisfied by an STC figure however close it looks.

**Why is the figure measured in a finished building always lower?**

Because a laboratory measures the ELEMENT and a building measures the RESULT, and most of the difference is flanking. A lab test isolates a wall between two rooms that share nothing else; a real wall sits in a building with a floor running continuously under it, a ceiling void above it, a screed crossing it, services penetrating it and junctions at every edge. Sound takes all of those routes. That is why British regulation specifies DnT,w + Ctr measured on site rather than accepting a wall specification, why Canada introduced ASTC alongside STC, and why remedial work on noise between dwellings so often has to address the floor or the junctions rather than the wall everybody is complaining about. A wall achieving its lab figure in a building is the exception.

**What is Ctr, and why does it change the answer so much?**

It is a correction that re-weights the rating toward LOW frequencies, and it is included precisely because the single-figure rating without it flatters constructions that are poor at the bass end. The unweighted rating is dominated by mid frequencies — speech — while the noise that actually causes complaints between dwellings is traffic, music and footfall, all of which have most of their energy low down. Ctr is always negative and is larger for lightweight constructions, because mass is what stops low frequencies and a light wall has little. The practical consequence is that a lightweight partition can post a respectable headline figure and a poor one once Ctr is applied, which is exactly the case where occupants report that they can hear the neighbour's television through a wall that passed on paper.

## More terminology

The terms this one is usually confused with, and the rest of the set.

- [Party wall and separating wall](https://craftquantities.com/glossary/party-wall/)
- [Impact sound insulation](https://craftquantities.com/glossary/impact-sound/)
- [Plasterboard / drywall](https://craftquantities.com/glossary/plasterboard/)
- [Timber / lumber](https://craftquantities.com/glossary/timber/)
- [Cladding / siding](https://craftquantities.com/glossary/cladding/)
- [Gutter / eavestrough](https://craftquantities.com/glossary/gutter/)

---
Source: https://craftquantities.com/glossary/sound-rating/