# Lintel and header

> United States and Canada: header. United Kingdom and Australia: lintel. The beam over a door, window or other opening that carries the wall above it and…

Page: https://craftquantities.com/glossary/lintel/ (glossary concept). This is the page's Markdown copy; the HTML page is the canonical version.

The beam over a door, window or other opening that carries the wall above it and delivers that load to the masonry or framing each side. Called a lintel in British and Australian practice and a header in North American framing.

- 4 Markets
- No Same thing everywhere
- 3 Calculators

## What it is called, by market

One concept, four markets. Where a name means something else locally, the card says so rather than leaving you to find out on site.

- ### United Kingdom

  Close, not identical

  lintel

  also cavity lintel, box lintel, catnic

  Usually a manufactured steel section or a precast concrete unit rather than timber, and in a cavity wall a single lintel commonly spans both leaves and carries a damp-proof tray.
- ### Australia

  Close, not identical

  lintel

  also head beam, galvanised lintel

  As the UK for masonry, but in timber-framed construction the member over an opening is frequently called a head or head trimmer instead.
- ### United States yours

  Same word, different thing

  header

  also door header, window header, lintel

  In British usage a header is a brick laid with its end showing, a header tank is a cold-water cistern, and a header is a pipework manifold. None of them spans an opening.
- ### Canada

  Same word, different thing

  header

  also lintel, built-up header

  As the United States, with lintel reserved more often for masonry and header used for the timber member in framing.

## The governing standard, by market

- United Kingdom

  BS EN 845-2

  Specification for ancillary components: lintels, including their load classification and testing.
- United States

  IRC Table R602.7

  Prescriptive header spans for wood framing, by species, size and loading condition.

## Calculators for this

Each works in either measurement system, and the terminology on the page follows whichever market you have selected.

- [Masonry Lintel Bearing Length Checker](https://craftquantities.com/calculators/materials-quantities/lintel-bearing-length-calculator/)
- [Masonry Lintel Uniform Load Capacity Calculator](https://craftquantities.com/calculators/materials-quantities/lintel-load-capacity-calculator/)
- [Steel I-Beam Weight-per-Length Calculator](https://craftquantities.com/calculators/materials-quantities/steel-i-beam-weight-calculator/)

## Frequently asked questions

**Does a header mean the same thing as a lintel?**

Structurally yes, materially usually not, and the word itself is a trap in British usage. Both name the member spanning an opening and carrying what sits above it. But an American header is typically built up from dimensional lumber — two or three members nailed together with packing between them, sized from a span table — whereas a British lintel is generally a manufactured steel profile or a precast concrete unit selected from a manufacturer's load tables. So converting a specification is not a matter of swapping the word: a timber header span table has no entry for a cavity-wall steel lintel, and the British lintel additionally carries a damp-proof tray across the cavity that the timber member never had to. And in British usage the word header is already taken three times over, by a brick laid end-on, a cold-water cistern and a pipework manifold.

**What is bearing length, and why does it get specified separately?**

It is how far the lintel sits onto the wall at each end, and it is a separate check because the lintel can be strong enough while the masonry under its ends is not. The load the lintel collects has to pass into the wall through that contact area, so a short bearing concentrates the same force over less masonry and can crush it — which is why manufacturers state a minimum bearing, commonly 100 mm or 150 mm depending on the span and load, and why a padstone appears under a heavily loaded end. It also changes the ORDER LENGTH: the lintel you buy is the clear opening plus two bearings, so a 1,800 mm opening with 150 mm bearings needs a 2,100 mm lintel. Ordering to the opening size is one of the commonest measuring errors on a job.

**Why do lintels over cavity walls look so different from solid-wall ones?**

Because they are doing a second job as well as spanning. A cavity wall has two leaves with a gap between them, and water that crosses the outer leaf has to be caught and sent back out rather than reaching the inner leaf. So a cavity lintel is profiled to support both leaves and to act as a tray, with a rise across the cavity and stop ends, and weep holes are left in the perimeter joint above it so the collected water can escape. A solid-wall lintel only has to span. That is why a cavity lintel is specified by the wall build-up it suits — cavity width, leaf thicknesses, insulation — and not by span and load alone.

## More terminology

The terms this one is usually confused with, and the rest of the set.

- [Steel beam designations](https://craftquantities.com/glossary/rsj/)
- [Brickwork bond](https://craftquantities.com/glossary/brick-bond/)
- [Plasterboard / drywall](https://craftquantities.com/glossary/plasterboard/)
- [Timber / lumber](https://craftquantities.com/glossary/timber/)
- [Cladding / siding](https://craftquantities.com/glossary/cladding/)
- [Gutter / eavestrough](https://craftquantities.com/glossary/gutter/)

---
Source: https://craftquantities.com/glossary/lintel/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.