# Fused connection unit

> United Kingdom: fused spur. Australia: fused connection unit. United States and Canada: (no direct equivalent). A fixed wiring accessory containing a…

Page: https://craftquantities.com/glossary/fused-spur/ (glossary concept). This is the page's Markdown copy; the HTML page is the canonical version.

A fixed wiring accessory containing a cartridge fuse, connecting an appliance permanently to a circuit at a lower protection level than the circuit itself carries.

- 4 Markets
- No Same thing everywhere
- 3 Calculators

## What it is called, by market

One concept, four markets. Where a name means something else locally, the card says so rather than leaving you to find out on site.

- ### United Kingdom

  No local equivalent

  fused spur

  also FCU, fused connection unit, switched spur, flex outlet

  Exists because a ring final circuit is protected at 32 A while an appliance flex is not. A SPUR strictly means a branch off a ring; the fuse and the spur are separate ideas commonly named together.
- ### Australia

  No local equivalent

  fused connection unit

  also appliance outlet, switched fused outlet

  Radial circuits at lower protection levels mean the component is uncommon; a fixed appliance is normally supplied from its own appropriately rated circuit instead.
- ### United States yours

  No local equivalent

  (no direct equivalent)

  also junction box, appliance disconnect, hard-wired connection

  A branch circuit is protected at 15 or 20 A, which the appliance cord survives, so no intermediate fuse is required. Where local protection is needed the appliance carries it internally.
- ### Canada

  No local equivalent

  (no direct equivalent)

  also junction box, disconnect means

  As the United States, with a local disconnect required for some fixed appliances — which is about isolation for maintenance rather than about protecting a flex.

## The governing standard, by market

- United Kingdom

  BS 1363-4 / BS 7671

  Fused connection units as part of the 13 A plug and socket system, and the wiring regulations governing spurs off a final circuit.
- United States

  NFPA 70 (NEC) Article 422

  Appliances: branch circuit sizing, disconnecting means, and the conditions for permanent connection.

## Calculators for this

Each works in either measurement system, and the terminology on the page follows whichever market you have selected.

- [Breaker Size Calculator](https://craftquantities.com/calculators/electrical/breaker-size-calculator/)
- [Outlets Per Circuit Calculator](https://craftquantities.com/calculators/electrical/outlets-per-circuit-calculator/)
- [Wire Gauge Voltage Drop Calculator (Copper or Aluminum, AWG to 1,000 kcmil)](https://craftquantities.com/calculators/electrical/wire-gauge-voltage-drop-calculator/)

## Frequently asked questions

**Why does Britain need a component nobody else does?**

Because the ring final circuit protects the cable in the wall at 32 A, which is far more than anything plugged into it can survive. On a portable appliance the plug carries the fuse and solves it. On a FIXED appliance — an extractor fan, a boiler, a towel rail, an outdoor light, a waste disposal — there is no plug, so without something in between the appliance's flex is connected directly to 32 A of available protection. The fused connection unit is that something: a fixed accessory with a cartridge fuse rated for the appliance, and usually a switch so the appliance can be isolated. An American branch circuit protected at 15 or 20 A does not create the gap, so the component never had to be invented.

**What is a spur, and how many are allowed?**

A spur is a branch taken off a ring rather than part of the loop itself, and the rules exist because a spur is the one part of a ring not protected by having two paths. A single unfused spur may supply one single or one double socket, or one fixed appliance, and it is taken from a socket on the ring or from a junction box in it — the reasoning being that the spur cable carries only what that one point draws, not the whole ring's load. Anything beyond that goes through a FUSED spur, which drops the protection to the fuse rating and so allows a much smaller cable and more outlets beyond it. The common domestic error is extending a spur with a second socket, which puts two outlets on a cable protected at 32 A with no second path.

**Switched or unswitched, and does the fuse rating matter?**

A switched unit suits anything that will need servicing and an unswitched one anything nobody should turn off, and the fuse matters: 3 A for small loads, 13 A for heating loads. SWITCHED lets the appliance be isolated locally, which is what makes it safe to work on a boiler or a fan without going to the consumer unit, and it is why a switched unit is normal for anything that will ever need servicing. UNSWITCHED is used where nobody should casually turn the appliance off — a freezer, an alarm, a trickle-charging circuit — and the switch would be a hazard rather than a convenience. The FUSE rating is chosen for the appliance and its flex, not for convenience: 3 A for small loads, 13 A for heating loads, and fitting 13 A everywhere because it is what came in the box removes the protection the unit exists to provide.

## More terminology

The terms this one is usually confused with, and the rest of the set.

- [Ring final and branch circuits](https://craftquantities.com/glossary/ring-final-circuit/)
- [Plasterboard / drywall](https://craftquantities.com/glossary/plasterboard/)
- [Timber / lumber](https://craftquantities.com/glossary/timber/)
- [Cladding / siding](https://craftquantities.com/glossary/cladding/)
- [Gutter / eavestrough](https://craftquantities.com/glossary/gutter/)

---
Source: https://craftquantities.com/glossary/fused-spur/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.