Version 1.0.0, sources checked 2026-09-21, 5 published test vectors.

Toilets, minimum: 3 toilets for People on Site at the Busiest Time 30, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| People on Site at the Busiest Time | `people` | 30 | 30 | range 1–5000 |
| Table to Apply | `basis` | Great Britain — Workplace Regulations ACoP L24, Table 1 | Great Britain — Workplace Regulations ACoP L24, Table 1 | `uk`, `us` |

- **People on Site at the Busiest Time**: The most people working on site at one time, all trades together.
- **Table to Apply**: Which published table the counts come from.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Toilets, minimum** | 3 toilets |
| Washing stations | 3 washing stations |
| People per toilet | 10 people |

### US customary

| Result | Value |
|---|---|
| **Toilets, minimum** | 3 toilets |
| Washing stations | 3 washing stations |
| People per toilet | 10 people |

## How it is worked out

For 30 people, Table 1 of L24 gives 3 toilets and 3 washing stations. The ACoP has a second table for men only, with urinals, which this page does not apply; on a construction site CDM 2015 Schedule 2 asks for facilities that are suitable and sufficient, and L24's numbers are the published measure of sufficient.

The working the page shows, in order: Washing stations; People per toilet; then toilets, minimum.

The method, derived in full:

- [Exposure at Work: Doses, Decibels and the Reference Day](https://craftquantities.com/methodology/exposure-at-work/): Why an hour at 94 dB(A) is a whole day at 85, why two countries' rules disagree about the same shift, why twice the vibration is four times the dose, and why a protector rated 30 dB takes off far less.

What this calculation does not cover:

- These are minimum numbers of fittings, not a welfare design. Separate facilities for men and women, an accessible facility, heating, lighting, ventilation and a regular cleaning and servicing schedule are all required on top.
- Washing facilities need hot and cold or warm running water, soap and a means of drying, and should be next to the toilets and near changing areas; a basin count alone does not describe them.
- Rest areas, drinking water, changing rooms and somewhere to store and dry clothing are part of site welfare too and are not counted here.
- The count is for people working at one time. A site whose peak is short but intense is sized for the peak.

## Sources

As the calculator cites them (sources checked 2026-09-21):

- Workplace (Health, Safety and Welfare) Regulations 1992, Approved Code of Practice L24, Table 1 (mixed use or women): 1 to 5 people, 1 toilet and 1 washing station; 6 to 25, 2 of each; 26 to 50, 3; 51 to 75, 4; 76 to 100, 5; and above 100, one more of each for every 25 people or part of 25
- Construction (Design and Management) Regulations 2015, Schedule 2: suitable and sufficient sanitary conveniences and washing facilities must be provided or made available at readily accessible places on a construction site
- 29 CFR 1926.51(c)(1), Table D-1: 20 employees or fewer, 1 toilet; 20 or more, 1 toilet seat and 1 urinal per 40 workers; 200 or more, 1 toilet seat and 1 urinal per 50 workers — and where the facilities will not be used by women, urinals may replace toilet seats down to two-thirds of the minimum number of seats

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Who counts towards the number?**

Everyone who will be working on site at the same time and using the facilities — every trade and every contractor, not only the principal contractor's own people — at the busiest point of the job. Facilities sized for the average headcount run out on exactly the days they are needed most.

**Why does the US table give fewer toilets at 200 workers than at 199?**

Because Table D-1 changes its ratio at 200, from one seat and one urinal per 40 workers to one of each per 50. Read literally, 199 workers need five seats and 200 need four. The table sets a minimum, not a target, and many employers simply keep the 40-worker ratio as the site grows rather than remove facilities as more people arrive.

**Do the numbers change for a small or short job?**

No: the British table starts at one toilet and one washing station for up to five people, and CDM 2015 applies to every construction site regardless of size. On a short job the facilities may be portable or shared with an occupied building by agreement, but they still have to be there from the first day. OSHA's table likewise starts at one toilet for up to 20 workers.

**Are washing facilities counted in the US too?**

OSHA's construction standard requires washing facilities where the work needs them — with paints, coatings, herbicides, lead and similar substances, for instance — but sets no ratio of basins to workers, so this page counts only toilets and urinals for a US site. The British table pairs each toilet with a washing station for every job.

## Related calculators

- [Workplace Exposure 8-Hour TWA Calculator (Dust, Fume, Vapour)](https://craftquantities.com/calculators/sustainability-compliance/workplace-exposure-twa-calculator/)
- [Daily Noise Exposure (LEP,d) Calculator](https://craftquantities.com/calculators/sustainability-compliance/daily-noise-exposure-calculator/)
- [Scaffold Face Area and Hire Quantity Calculator](https://craftquantities.com/calculators/materials-quantities/scaffold-face-area-calculator/)
- [Temporary Site Trailer Electrical Load Calculator](https://craftquantities.com/calculators/materials-quantities/site-trailer-electrical-load-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/site-welfare-facilities-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/site-welfare-facilities-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `site-welfare-facilities-calculator`.