# Fly Ash / Silica Fume SCM Replacement Calculator

> Split a concrete mix's cementitious content by mass into portland cement and an SCM, fly ash or silica fume, at a target replacement percentage.

Page: https://craftquantities.com/calculators/sustainability-compliance/scm-replacement-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.1, sources checked 2026-09-02, 2 published test vectors.

Portland cement required: 17.5 pcf for Total Cementitious Material Content 589.94 lb/yd³, the page's opening figures; on the metric page, 350 kg/m³ gives 280 kg per m³. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Total Cementitious Material Content | `totalCementitiousMass` | 350 kg/m³ | 589.944 lb/yd³ | kgm3, pcf, lbyd3; range 50–600 kg/m³ |
| SCM Type | `scmType` | Fly Ash (Class F, typical 15-30% replacement) | Fly Ash (Class F, typical 15-30% replacement) | `fly-ash`, `silica-fume` |
| Replacement Percentage | `replacementPercent` | 20 | 20 | range 5–40 |

- **Total Cementitious Material Content**: The total cement plus SCM, as mass per unit volume of concrete.
- **SCM Type**: The type of SCM being used.
- **Replacement Percentage**: The percentage of total cementitious mass to replace with the SCM.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Portland cement required** | 280 kg per m³ |
| SCM mass required | 70 kg per m³ |

### US customary

| Result | Value |
|---|---|
| **Portland cement required** | 17.5 pcf |
| SCM mass required | 4.37 pcf |

## How it is worked out

The working the page shows, in order: SCM mass required; then portland cement required.

The method, derived in full:

- [Carbon Accounting: Boundaries, Factors and What A1–A3 Leaves Out](https://craftquantities.com/methodology/carbon-accounting-and-boundaries/): Why two embodied carbon figures for the same product can differ by a factor and both be right, why a low-cement mix is partly an accounting decision, and why multiplying today's grid factor by thirty years overstates the answer.

What this calculation does not cover:

- This is a mass split and nothing else. It divides the binder you type at the percentage you type; it does not check that the resulting concrete meets its specified strength, water-cementitious ratio, air content or slump. Replacing cement changes water demand and admixture dosage, and none of that is recalculated here.
- It does not check your project specification. Specs, exposure classes and durability provisions routinely cap how much fly ash or silica fume is permitted, and some structural and cold-weather applications restrict it further. The confidence note only compares your percentage against a published typical band, never against the job you are batching for.
- Nothing about the SCM material itself is modelled: fly ash class and loss on ignition, whether silica fume arrives densified or as slurry, alkali and sulfate content, or batch-to-batch variability. It assumes a conforming, tested material (ASTM C618 for fly ash, C1240 for silica fume) and treats every unit of SCM as the same mass of cement removed.
- Early strength gain is not adjusted. Fly ash mixes build strength more slowly at early ages, and this calculation gives you no revised age for formwork striking, post-tensioning, sawcutting or opening to traffic. Those come from trial mixes or in-place maturity testing, not from a mass split.
- One SCM at a time, and no carbon number. Ternary blends of cement plus fly ash plus silica fume are not computed in a single pass, and the calculator reports no embodied-carbon saving — the mass split alone does not produce a kgCO2e figure.

A professional must decide:

- It does not check your project specification. Specs, exposure classes and durability provisions routinely cap how much fly ash or silica fume is permitted, and some structural and cold-weather applications restrict it further.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Supplementary cementitious materials commonly replace 15-30% of portland cement by mass for fly ash (ACI 232.2R) and 5-10% for silica fume (ACI 234R), reducing embodied carbon and, at these replacement levels, generally improving long-term strength and durability

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why replace portland cement with an SCM?**

Portland cement production is a major source of embodied carbon; fly ash and silica fume are industrial byproducts that reduce cement demand while typically improving long-term strength, reducing permeability, and often improving workability.

**Does using an SCM slow down strength gain?**

Usually yes for fly ash, especially at early ages (the first 7-28 days) — the mix design and curing schedule should account for this, particularly on fast-track construction schedules.

**Can I combine fly ash and silica fume in the same mix?**

Yes, ternary blends (portland cement + fly ash + silica fume) are common in high-performance concrete — this calculator handles one SCM type at a time; run it twice and subtract for a ternary blend.

## Related calculators

- [Concrete Mix Ratio Calculator](https://craftquantities.com/calculators/materials-quantities/concrete-mix-ratio-calculator/)
- [Concrete Calculator](https://craftquantities.com/calculators/materials-quantities/concrete-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/scm-replacement-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/scm-replacement-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `scm-replacement-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/scm-replacement-calculator.json

---
Source: https://craftquantities.com/calculators/sustainability-compliance/scm-replacement-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.