# Hearing Protection Attenuation Calculator (SNR, HML, NRR)

> Estimate the noise reaching the ear under an earplug or earmuff from its SNR, HML or NRR rating, with the real-world allowance HSE and OSHA each apply.

Page: https://craftquantities.com/calculators/sustainability-compliance/hearing-protection-attenuation-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-21, 5 published test vectors.

Estimated level at the ear: 72 dB(A) for A-Weighted Noise Level, LAeq (dB(A)) 95, C-Weighted Noise Level, LCeq (dB(C)) 98 and SNR 30, the page's opening figures, to compare with the limit shown with it; a comparison, not a check. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Rating on the Protector | `method` | SNR — single number rating (UK, EU and most of the world) | SNR — single number rating (UK, EU and most of the world) | `snr`, `hml`, `nrr` |
| A-Weighted Noise Level, LAeq (dB(A)) | `laeq` | 95 | 95 | range 60–140 |
| C-Weighted Noise Level, LCeq (dB(C)) | `lceq` | 98 | 98 | range 60–140 |
| SNR (dB) | `snr` | 30 | 30 | range 5–45 |
| H Value (dB) | `hValue` | 32 | 32 | range 5–45 |
| M Value (dB) | `mValue` | 24 | 24 | range 5–45 |
| L Value (dB) | `lValue` | 17 | 17 | range 1–45 |
| NRR (dB) | `nrr` | 29 | 29 | range 5–40 |
| How the Noise Was Measured | `nrrWeighting` | A-weighted (dBA) — the NRR is reduced by 7 dB first | A-weighted (dBA) — the NRR is reduced by 7 dB first | `a`, `c` |
| Allow for Real-World Fit | `realWorld` | Yes — HSE's 4 dB, or OSHA's 50% for an NRR | Yes — HSE's 4 dB, or OSHA's 50% for an NRR | `yes`, `no` |

- **Rating on the Protector**: Which rating the packaging or data sheet gives.
- **A-Weighted Noise Level, LAeq (dB(A))**: The measured A-weighted level at the worker's position — used by the HML and A-weighted NRR methods.
- **C-Weighted Noise Level, LCeq (dB(C))**: The measured C-weighted level at the same position — used by the SNR, HML and C-weighted NRR methods.
- **SNR (dB)**: The single number rating printed on the protector.
- **H Value (dB)**: The protector's rating for high-frequency noise.
- **M Value (dB)**: The protector's rating for mid-frequency noise.
- **L Value (dB)**: The protector's rating for low-frequency noise.
- **NRR (dB)**: The noise reduction rating on the US packaging.
- **How the Noise Was Measured**: Whether the level the NRR is deducted from is A- or C-weighted.
- **Allow for Real-World Fit**: Whether to reduce the rating for how protectors are actually worn.

`snr` applies only when `method` is `snr`.
`hValue` applies only when `method` is `hml`.
`mValue` applies only when `method` is `hml`.
`lValue` applies only when `method` is `hml`.
`nrr` applies only when `method` is `nrr`.
`nrrWeighting` applies only when `method` is `nrr`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Estimated level at the ear** | 72 dB(A) |
| Level the rating is deducted from | 98 dB(C) |
| Protection assumed | 26 dB |
| Real-world allowance taken off the rating | 4 dB |

### US customary

| Result | Value |
|---|---|
| **Estimated level at the ear** | 72 dB(A) |
| Level the rating is deducted from | 98 dB(C) |
| Protection assumed | 26 dB |
| Real-world allowance taken off the rating | 4 dB |

- Confidence: medium.
- The figure is compared against a limit; that is a check of the number, not an approval.

## How it is worked out

At 72.0 dB(A) the estimate is inside the 70 to 80 dB(A) band HSE advises aiming for at the ear. The estimate assumes the protector is worn correctly for the whole time in the noise; only fit testing or an in-ear measurement shows the level actually reaching the ear.

The working the page shows, in order: Level the rating is deducted from; Protection assumed; Real-world allowance taken off the rating; then estimated level at the ear.

The method, derived in full:

- [Exposure at Work: Doses, Decibels and the Reference Day](https://craftquantities.com/methodology/exposure-at-work/): Why an hour at 94 dB(A) is a whole day at 85, why two countries' rules disagree about the same shift, why twice the vibration is four times the dose, and why a protector rated 30 dB takes off far less.

What this calculation does not cover:

- The ratings come from laboratory tests with a perfect fit. Long hair, spectacle arms, a hood, a badly inserted earplug and a protector removed for part of the time all cut the protection achieved — a few minutes without protection in a loud area loses much of its value over the day.
- The octave-band method in BS EN ISO 4869-2 is more accurate than either SNR or HML where the spectrum is known, and is not implemented here.
- It estimates the steady level at the ear. Impulse noise, where the peak matters, needs the protector checked against the peak values as well.
- Plugs and muffs worn together do not add their ratings; the combination gains far less than the sum, and no simple rating predicts it.

## Sources

As the calculator cites them (sources checked 2026-09-21):

- BS EN ISO 4869-2 and HSE L108: with the SNR, the A-weighted level under the protector is LC − SNR; with the H, M and L values, the predicted noise level reduction is PNR = M − (H − M)(LC − LA − 2) ÷ 4 where LC − LA is 2 dB or less and PNR = M − (M − L)(LC − LA − 2) ÷ 8 where it is more, and the level at the ear is LA − PNR
- HSE L108 (Controlling noise at work): to allow for real-world factors, reduce the protection of any hearing protector by 4 dB; aim for a level at the ear between 70 and 80 dB(A), since protection taking it below 70 dB(A) over-protects and isolates the wearer
- 29 CFR 1910.95, Appendix B: where the noise is measured A-weighted, subtract 7 dB from the NRR before deducting it, and where it is measured C-weighted, deduct the NRR directly; the OSHA Technical Manual, Section III, Chapter 5, derates the resulting attenuation by 50 per cent to allow for real-world fit

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does a protector rated 30 dB not take 30 dB off?**

Because the rating is measured in a laboratory, on people trained to fit it perfectly, and real use is not like that. Earplugs are seldom inserted as deeply, muffs sit over spectacle arms and hair, and protectors come off for a moment in the middle of noisy work. HSE advises taking 4 dB off any rating for real-world use; for US NRRs, OSHA's guidance halves the protection. Even then the figure is an estimate, and fit training does more for the real number than a higher rating does.

**Should I use the SNR or the HML method?**

The HML method where you have both the A- and C-weighted levels, because it accounts for what kind of noise it is. Low-frequency noise — big engines, compressors, vibrating plant — is harder to stop, and a protector's L value is always its lowest; the SNR averages that away. The octave-band method is better still where a full spectrum has been measured, and it is what a specialist would use for a difficult case.

**How is an NRR used on a US site?**

If the noise was measured with A-weighting, as most dosimeters and meters report it, OSHA's Appendix B subtracts 7 dB from the NRR and deducts the rest; with a C-weighted measurement the NRR is deducted as printed. The OSHA Technical Manual then halves the protection to allow for real-world fit, so an NRR of 29 against 100 dBA leaves about 89 dBA at the ear rather than the 78 the printed figure suggests.

**Is more protection always better?**

No. HSE advises aiming for 70 to 80 dB(A) at the ear and treats less than 70 as over-protection: a worker who cannot hear warnings, reversing alarms or speech is more likely to lift the protector off, which costs far more protection than the extra rating bought. The best protector is the one that brings the level into that band and is comfortable enough to be worn for the whole time in the noise.

## Related calculators

- [Daily Noise Exposure (LEP,d) Calculator](https://craftquantities.com/calculators/sustainability-compliance/daily-noise-exposure-calculator/)
- [OSHA Noise Dose and 8-Hour TWA Calculator](https://craftquantities.com/calculators/sustainability-compliance/osha-noise-dose-calculator/)
- [Weekly Noise Exposure (LEP,w) Calculator](https://craftquantities.com/calculators/sustainability-compliance/weekly-noise-exposure-calculator/)
- [Decibel Addition and Background Correction Calculator](https://craftquantities.com/calculators/sustainability-compliance/decibel-addition-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/hearing-protection-attenuation-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/hearing-protection-attenuation-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `hearing-protection-attenuation-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/hearing-protection-attenuation-calculator.json

---
Source: https://craftquantities.com/calculators/sustainability-compliance/hearing-protection-attenuation-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.