# Greywater Collection Cistern Peak Inflow Calculator

> Calculate the peak inflow rate a greywater collection cistern must handle, from average daily flow and a peaking factor.

Page: https://craftquantities.com/calculators/sustainability-compliance/greywater-cistern-peak-inflow-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Peak inflow rate: 325 gal/day for Average Daily Greywater Flow 130 gal, the page's opening figures; on the metric page, 500 L gives 1,250 L/day. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Average Daily Greywater Flow | `avgDailyFlow` | 500 L | 130 gal | l, gal, m3, ft3, yd3; range 50–5000 L |
| Peaking Factor | `peakingFactor` | 2.5 | 2.5 | range 1.5–4 |

- **Average Daily Greywater Flow**: The building's average daily greywater generation.
- **Peaking Factor**: The multiplier applied to the daily average to size for short-duration peak demand.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Peak inflow rate** | 1,250 L/day |

### US customary

| Result | Value |
|---|---|
| **Peak inflow rate** | 325 gal/day |

- Confidence: medium.

## How it is worked out

Peaking factor depends on the building's occupancy pattern and fixture usage profile — confirm the appropriate factor for your specific application against local greywater reuse code requirements.

The method, derived in full:

- [Stormwater, Runoff and the Water Balance](https://craftquantities.com/methodology/stormwater-and-water-balance/): Why a small catchment is designed for a more intense rainfall than a large one, why a detention basin can make things worse downstream, and why a rainwater tank delivers far less than annual rainfall times roof area.

What this calculation does not cover:

- The answer is a flow per day, not the flow an inlet actually sees. Multiplying a daily average by a peaking factor carries no duration, so it cannot tell you the flow per minute arriving when two showers and a washing machine discharge at once — size inlet pipework, filters, diverters and transfer pumps from fixture discharge rates, not from this figure.
- Nothing here sizes the cistern itself. Storage volume, retention time, drawdown against reuse demand, overflow to sewer and any make-up water arrangement are separate calculations, and greywater codes generally cap how long untreated greywater may be held before it must be used or discharged.
- No treatment or water-quality content: screening, settling, filtration, disinfection and the rules on which fixtures may feed the system (kitchen sink and dishwasher waste is excluded in many jurisdictions) are all outside the model. It is also not a compliance check — permits, cross-connection control, backflow protection and non-potable pipe labelling are set by your local greywater code.
- The peaking factor is never checked against anything: no fixture count, occupancy schedule, or code table. The result is a straight multiplication, so a factor borrowed from a different building type — or from a different peak definition, peak day versus peak hour — passes straight through to the answer with nothing flagging it.
- Daily flows outside 50–5,000 L/day (13–1,320 gal/day) and factors outside 1.5–4 are pulled back to those bounds rather than calculated. A building generating more than about 5,000 L/day of greywater cannot be entered whole; it has to be split and run per wing or per riser.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Peak inflow rate = average daily flow × peaking factor, the standard method for sizing detention/collection systems to handle short-duration peak demand rather than just the daily average

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why size the cistern for a peak rate instead of the daily average?**

A collection/detention system has to handle the short-duration surges in greywater generation — for example, several showers or a laundry cycle running close together — not just the smoothed-out daily average, so peak inflow rate is the standard basis for sizing.

**What peaking factor should I use?**

Peaking factor depends on the building's occupancy pattern and fixture usage profile. Confirm the appropriate factor for your specific application against local greywater reuse code requirements rather than assuming a single universal value.

**Does this account for local greywater reuse code requirements?**

No — this calculator only scales your average daily flow by the peaking factor you provide. The appropriate peaking factor, and any additional sizing margins, must be confirmed against your local greywater reuse code.

## Related calculators

- [Sump Pump GPM Calculator](https://craftquantities.com/calculators/plumbing-hvac/sump-pump-gpm-calculator/)
- [Foundation Sheet Drain Drainage Rate Calculator](https://craftquantities.com/calculators/materials-quantities/sheet-drain-rate-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/greywater-cistern-peak-inflow-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/greywater-cistern-peak-inflow-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `greywater-cistern-peak-inflow-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/greywater-cistern-peak-inflow-calculator.json

---
Source: https://craftquantities.com/calculators/sustainability-compliance/greywater-cistern-peak-inflow-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.