# Decibel Addition and Background Correction Calculator

> Add up to six sound levels on an energy basis, or take a background level out of a measured total to find what the source produces on its own.

Page: https://craftquantities.com/calculators/sustainability-compliance/decibel-addition-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-21, 4 published test vectors.

Resulting level: 87.4 dB (combined) for Level 1 85, Level 2 82 and Level 3 79, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| What to Work Out | `mode` | Combine several levels into one | Combine several levels into one | `add`, `subtract` |
| Level 1 (dB, 0 to leave out) | `level1` | 85 | 85 | range 0–200 |
| Level 2 (dB, 0 to leave out) | `level2` | 82 | 82 | range 0–200 |
| Level 3 (dB, 0 to leave out) | `level3` | 79 | 79 | range 0–200 |
| Level 4 (dB, 0 to leave out) | `level4` | 0 | 0 | range 0–200 |
| Level 5 (dB, 0 to leave out) | `level5` | 0 | 0 | range 0–200 |
| Level 6 (dB, 0 to leave out) | `level6` | 0 | 0 | range 0–200 |
| Measured Total Level (dB) | `total` | 88 | 88 | range 1–200 |
| Background Level (dB) | `background` | 82 | 82 | range 0–200 |

- **What to Work Out**: Adding sources together, or removing the background from a measurement.
- **Level 1 (dB, 0 to leave out)**: One source's level, in the same weighting as all the others.
- **Level 2 (dB, 0 to leave out)**: One source's level, in the same weighting as all the others.
- **Level 3 (dB, 0 to leave out)**: One source's level, in the same weighting as all the others.
- **Level 4 (dB, 0 to leave out)**: One source's level, in the same weighting as all the others.
- **Level 5 (dB, 0 to leave out)**: One source's level, in the same weighting as all the others.
- **Level 6 (dB, 0 to leave out)**: One source's level, in the same weighting as all the others.
- **Measured Total Level (dB)**: The level measured with the source running.
- **Background Level (dB)**: The level at the same position with the source switched off.

`level1` applies only when `mode` is `add`.
`level2` applies only when `mode` is `add`.
`level3` applies only when `mode` is `add`.
`level4` applies only when `mode` is `add`.
`level5` applies only when `mode` is `add`.
`level6` applies only when `mode` is `add`.
`total` applies only when `mode` is `subtract`.
`background` applies only when `mode` is `subtract`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Resulting level** | 87.4 dB (combined) |
| Level 1's share of the total energy | 57.07 % |
| Level 2's share of the total energy | 28.6 % |
| Level 3's share of the total energy | 14.33 % |
| Rise over the loudest single level | 2.44 dB |

### US customary

| Result | Value |
|---|---|
| **Resulting level** | 87.4 dB (combined) |
| Level 1's share of the total energy | 57.07 % |
| Level 2's share of the total energy | 28.6 % |
| Level 3's share of the total energy | 14.33 % |
| Rise over the loudest single level | 2.44 dB |

## How it is worked out

3 levels combine to 87.4 dB, 2.4 dB above the loudest of them on its own.

The working the page shows, in order: Level 1's share of the total energy; Level 2's share of the total energy; Level 3's share of the total energy; Rise over the loudest single level; then resulting level.

The method, derived in full:

- [Exposure at Work: Doses, Decibels and the Reference Day](https://craftquantities.com/methodology/exposure-at-work/): Why an hour at 94 dB(A) is a whole day at 85, why two countries' rules disagree about the same shift, why twice the vibration is four times the dose, and why a protector rated 30 dB takes off far less.

What this calculation does not cover:

- Every level must use the same weighting and the same position. Adding an A-weighted level to a C-weighted one, or a sound power level to a sound pressure level, produces a number that means nothing.
- The energy sum assumes the sources are unrelated, which is true of machines, voices and traffic. Two identical pure tones in step with each other can add or cancel quite differently, and that case needs a specialist.
- A background correction is only as good as the two measurements behind it: the background has to be taken at the same place and in the same conditions, with the source off, and it changes through the day.

## Sources

As the calculator cites them (sources checked 2026-09-21):

- Sound levels combine on energy: L = 10 log10(10^(L1 ÷ 10) + 10^(L2 ÷ 10) + … + 10^(Ln ÷ 10)), so two equal levels are 3.01 dB above either and a level 10 dB below another adds 0.41 dB to it
- The residual-sound correction used in ISO 1996-2 and BS 4142: the source alone is Ls = 10 log10(10^(Lt ÷ 10) − 10^(Lb ÷ 10)), the same energy arithmetic in reverse, which depends on the background being measured at the same position with the source off

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why do two 85 dB machines make 88 dB and not 170?**

Decibels are a logarithm of sound energy, so they cannot be added directly. Two machines give twice the energy of one, and twice the energy is 3 dB more on the logarithmic scale — 88 dB. Ten identical machines are 10 dB more than one. It works the other way too: switching off one of two equal machines only takes 3 dB off, which is why noise control starts with the loudest source rather than with the number of sources.

**Why does a much quieter source hardly change the total?**

Because its energy is a small fraction of the loud one's. A source 10 dB quieter than another carries a tenth of its energy and adds 0.4 dB to it; 20 dB quieter, it carries a hundredth and adds less than 0.05 dB. In a combination, the loudest level dominates so completely that quieter contributions can often be ignored — and silencing them achieves almost nothing.

**When is a background correction worth making?**

When the measured total is between about 3 and 10 dB above the background. Closer than 3 dB and a small error in either reading moves the answer a long way, so such a difference is commonly treated as too close to separate the source reliably. More than 10 dB and the correction is under half a decibel, so the total already describes the source. The background must be measured at the same position, with the same weighting and with the source switched off.

## Related calculators

- [Construction Plant Noise at a Neighbour Calculator (BS 5228-1 / FHWA RCNM)](https://craftquantities.com/calculators/sustainability-compliance/construction-noise-at-receptor-calculator/)
- [Daily Noise Exposure (LEP,d) Calculator](https://craftquantities.com/calculators/sustainability-compliance/daily-noise-exposure-calculator/)
- [OSHA Noise Dose and 8-Hour TWA Calculator](https://craftquantities.com/calculators/sustainability-compliance/osha-noise-dose-calculator/)
- [Hearing Protection Attenuation Calculator (SNR, HML, NRR)](https://craftquantities.com/calculators/sustainability-compliance/hearing-protection-attenuation-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/decibel-addition-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/decibel-addition-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `decibel-addition-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/decibel-addition-calculator.json

---
Source: https://craftquantities.com/calculators/sustainability-compliance/decibel-addition-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.