# Solar Array Row Spacing and Shading Pitch Calculator

> How far apart tilted solar rows must sit so one does not shade the next — with the ground coverage ratio that tilt is costing you.

Page: https://craftquantities.com/calculators/solar-energy/solar-row-spacing-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-23, 3 published test vectors.

Row pitch, front to front: 14.6 ft for Panel length up the slope 6.5 ft, the page's opening figures; on the metric page, 2 m gives 4.48 m. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Panel length up the slope | `panelLength` | 2 m | 6.5 ft | mm, cm, m, in, ft, yd; range 0.5–5 m |
| Tilt from horizontal | `tiltAngle` | 30 | 30 | range 0–60 |
| Design sun altitude | `sunAltitude` | 20 | 20 | range 3–60 |
| Depth available for rows | `availableDepth` | 20 m | 66 ft | mm, cm, m, in, ft, yd; range 1–500 m |

- **Panel length up the slope**: The panel dimension running up the tilt, not across it.
- **Tilt from horizontal**: Degrees. This is the figure the whole trade-off turns on.
- **Design sun altitude**: Degrees above the horizon at the worst moment you will accept.
- **Depth available for rows**: Front of the first row to the back boundary.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Row pitch, front to front** | 4.48 m |
| Clear gap behind each row | 2.75 m |
| Ground the panel occupies | 1.73 m |
| Height the row stands | 1 m |
| Ground coverage ratio | 38.67 % |
| Rows that fit the depth | 5 rows |

### US customary

| Result | Value |
|---|---|
| **Row pitch, front to front** | 14.6 ft |
| Clear gap behind each row | 8.93 ft |
| Ground the panel occupies | 5.63 ft |
| Height the row stands | 3.25 ft |
| Ground coverage ratio | 38.67 % |
| Rows that fit the depth | 5 rows |

- Confidence: medium.

## How it is worked out

61% of the pitch is clear ground the shadow needs, at a ground coverage ratio of 39%. 5 row(s) fit the depth given.

The working the page shows, in order: Clear gap behind each row; Ground the panel occupies; Height the row stands; Ground coverage ratio; Rows that fit the depth; then row pitch, front to front.

The method, derived in full:

- [Slope, Pitch and True Surface Area](https://craftquantities.com/methodology/slope-pitch-and-true-area/): Converting a plan footprint into the sloped area a roof actually has — the factor that decides whether a shingle order is right or a third short.

What this calculation does not cover:

- The shadow is taken at the array's worst moment with the sun square to the rows. As the sun swings off that line its shadow shortens, so a full azimuth model returns a SMALLER pitch than this one — the error here is in the safe direction, and it is deliberate.
- Flat ground is assumed. A slope falling away from the sun lets rows sit closer and a slope rising behind them pushes them further apart, and neither is a small effect: a few degrees of ground slope moves the pitch more than a few degrees of tilt does.
- Row-to-row shading only. Nothing here sees a chimney, a flue, a parapet, a tree or the next building, and on a roof those are usually what actually decides the layout.
- It is a geometric limit, not a yield model. Accepting a little winter shading is a legitimate design choice that fits more panels on the site and can produce more annual energy than a sparser array — this page tells you what you are trading, not which trade is right.

A professional must decide:

- Electrics: circuit design, protection, cable sizing and the work itself are for a qualified or licensed electrician, under the rules where you build.

## Sources

As the calculator cites them (sources checked 2026-09-23):

- Geometry: a panel of slope length L at tilt β stands L·sin β high and occupies L·cos β of ground, so at sun altitude α its shadow reaches (L·sin β)/tan α behind it and the row pitch is the sum of the two
- The usual design criterion is no row-to-row shading between 9 am and 3 pm on the winter solstice, which is when the sun is lowest in the working day
- Ground coverage ratio is the panel footprint divided by the row pitch — the share of the site that is under panel, and the direct cost of tilting further

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**How far apart should solar rows be?**

Far enough that the top of one row does not shade the foot of the next at your design moment. A 2 m panel at 30° stands 1 m high and occupies 1.73 m of ground; at a 20° sun that 1 m throws a 2.75 m shadow, so the pitch is about 4.48 m — roughly 14 ft 8 in. That is two and a half times the panel's own footprint, which is why a ground array needs so much more land than its panel area suggests.

**Why does tilting the panels cost me rows?**

Because height and shadow rise together while footprint falls. Going from 15° to 30° on a 2 m panel takes the row from 0.52 m (1 ft 8 in) high to 1 m (3 ft 3 in), nearly doubling the shadow, while the ground each row occupies shrinks — so the pitch goes from about 3.35 m (11 ft 0 in) to 4.48 m (14 ft 8 in) and the ground coverage ratio drops from 58% to 39%. On a depth-limited site a flatter array often produces more total energy than a steeper one, simply because more of it fits.

**What sun altitude should I design to?**

The usual criterion is no row-to-row shading between 9 am and 3 pm on the winter solstice, because that is when the sun is lowest during the working day. At solar noon on the solstice the sun reaches roughly 90° minus your latitude minus 23.4°, and it is lower than that at 9 am — so take the altitude at the hour you actually care about. The figure matters: dropping from 20° to 10° takes the pitch from 4.48 m (14 ft 8 in) to 7.40 m (24 ft 3 in).

**Is some shading ever acceptable?**

Often, and this page deliberately does not decide it for you. Accepting a little shading on midwinter mornings lets you fit more rows on the same ground, and more panels lightly shaded for a few hours a year can out-produce fewer panels never shaded at all. What the page gives you is the geometric limit and what your tilt is costing in ground coverage — the trade, not the verdict.

## Related calculators

- [Solar Panel Array Sizing Calculator](https://craftquantities.com/calculators/solar-energy/solar-panel-array-sizing-calculator/)
- [Solar Panel Roof Mount Wind Uplift Ballast Calculator](https://craftquantities.com/calculators/solar-energy/solar-mount-ballast-calculator/)
- [Solar PV String Sizing Calculator](https://craftquantities.com/calculators/solar-energy/pv-string-sizing-calculator/)
- [Solar Panel PV Wire Sizing Calculator](https://craftquantities.com/calculators/solar-energy/solar-pv-wire-sizing-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/solar-row-spacing-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/solar-row-spacing-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `solar-row-spacing-calculator`.