# Off-Grid Autonomy Calculator

> Work out how long a battery bank runs a given load, and how much array is needed to replace it each day.

Page: https://craftquantities.com/calculators/solar-energy/off-grid-autonomy-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-08-27, 4 published test vectors.

Autonomy: 25.5 hours for Battery nameplate 15, Usable share of nameplate 85 and Continuous load 0.5, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Battery nameplate (kWh) | `bankKwh` | 15 | 15 | range 0.5–5000 |
| Usable share of nameplate (%) | `usablePercent` | 85 | 85 | range 20–100 |
| Continuous load (kW) | `loadKw` | 0.5 | 0.5 | range 0.01–500 |
| Array size (kW DC) | `arrayKw` | 4 | 4 | range 0–1000 |
| Peak sun hours per day | `peakSunHours` | 3.5 | 3.5 | range 0.2–10 |

- **Battery nameplate (kWh)**: Rated capacity of the bank.
- **Usable share of nameplate (%)**: Depth of discharge times round-trip efficiency.
- **Continuous load (kW)**: Average continuous draw.
- **Array size (kW DC)**: Nameplate DC of the array.
- **Peak sun hours per day**: Daily solar resource at your site.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Autonomy** | 25.5 hours |
| Usable energy | 12.75 kWh |
| Days at this load | 1.06 days |
| Daily consumption | 12 kWh |
| Daily generation after losses | 12.04 kWh |
| Daily surplus or shortfall | 0.04 kWh |

### US customary

| Result | Value |
|---|---|
| **Autonomy** | 25.5 hours |
| Usable energy | 12.75 kWh |
| Days at this load | 1.06 days |
| Daily consumption | 12 kWh |
| Daily generation after losses | 12.04 kWh |
| Daily surplus or shortfall | 0.04 kWh |

- Confidence: medium.

## How it is worked out

Generation exceeds consumption on an average day at the stated sun hours.

The working the page shows, in order: Usable energy; Days at this load; Daily consumption; Daily generation after losses; Daily surplus or shortfall; then autonomy.

The method, derived in full:

- [Usable Battery Energy](https://craftquantities.com/methodology/usable-battery-energy/): The two multiplications that separate a battery's nameplate from what it will actually run — commonly a factor of two and a half.

What this calculation does not cover:

- Peak sun hours vary by season by a factor of two or more. An off-grid system must be sized on the worst month, not the annual average.
- Assumes the load is constant. Real loads cycle, and a system that works on averages can still fail on a bad evening.
- Ignores charge-controller limits and the fact that a full battery cannot absorb surplus generation.

## Sources

As the calculator cites them (sources checked 2026-08-27):

- Daily array yield = rated DC watts × peak sun hours × system derate; NREL PVWatts methodology
- Peak sun hours is the daily insolation in kWh/m² and varies by location and season — it is a site input, not a constant

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why size on the worst month?**

Because an off-grid system has no fallback. Peak sun hours in a northern winter can be a third of the summer figure, so a system sized on the annual average runs out in December — the month you least want it to. Size on the worst month, or accept a generator for that period and size on something between.

**What is a peak sun hour?**

An hour at 1000 W/m², the reference irradiance panels are rated at. A site with 3.5 peak sun hours receives 3.5 kWh/m² across the day, spread over more actual daylight at lower intensity. It is a way of collapsing a whole day's varying sunlight into one number that multiplies cleanly against a panel rating.

**Why does the surplus matter if the battery is full?**

It largely does not, and that is the point people miss. A full battery cannot absorb surplus, so generation above what the load takes is simply lost. Oversizing an array for the worst month means throwing away most of the summer output — which is fine, and cheaper than the battery that would store it.

## Related calculators

- [Battery Bank Sizing Calculator](https://craftquantities.com/calculators/solar-energy/battery-bank-sizing-calculator/)
- [Solar Inverter Sizing Calculator](https://craftquantities.com/calculators/solar-energy/inverter-sizing-calculator/)
- [Solar Panel Array Sizing Calculator](https://craftquantities.com/calculators/solar-energy/solar-panel-array-sizing-calculator/)
- [Generator Sizing Calculator](https://craftquantities.com/calculators/electrical/generator-sizing-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/off-grid-autonomy-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/off-grid-autonomy-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `off-grid-autonomy-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/off-grid-autonomy-calculator.json

---
Source: https://craftquantities.com/calculators/solar-energy/off-grid-autonomy-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.