# Battery Backup Runtime Calculator

> Estimate how long a battery backup system will power a load before depleting.

Page: https://craftquantities.com/calculators/solar-energy/battery-backup-runtime-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Estimated runtime: 5.67 hours for Battery Capacity 2000, Connected Load 300 and System Efficiency 85, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Battery Capacity (Wh) | `batteryCapacityWh` | 2000 | 2000 | range 50–50000 |
| Connected Load | `loadWatts` | 300 | 300 | range 1–10000 |
| System Efficiency (%) | `systemEfficiencyPercent` | 85 | 85 | range 30–100 |

- **Battery Capacity (Wh)**: The total energy storage capacity of the battery bank.
- **Connected Load**: The total wattage of everything running off the battery.
- **System Efficiency (%)**: Inverter losses AND the battery usable depth of discharge, multiplied together.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Estimated runtime** | 5.67 hours |
| Usable energy | 1,700 Wh |

### US customary

| Result | Value |
|---|---|
| **Estimated runtime** | 5.67 hours |
| Usable energy | 1,700 Wh |

- Confidence: medium.

## How it is worked out

Real-world runtime varies with battery age, temperature, and how deeply it's safely discharged (especially for lead-acid batteries, which shouldn't be fully depleted) — check your specific battery manufacturer's guidance.

The working the page shows, in order: Usable energy; then estimated runtime.

The method, derived in full:

- [Usable Battery Energy](https://craftquantities.com/methodology/usable-battery-energy/): The two multiplications that separate a battery's nameplate from what it will actually run — commonly a factor of two and a half.

What this calculation does not cover:

- Assumes the load is constant for the whole discharge. Anything that cycles - a fridge compressor, a well pump, a heat pump - draws its full watts only part of the time, so a runtime worked out from summed nameplates comes out far shorter than the bank really delivers, while one worked out from an average hides the peaks. The inverter's own standby draw also continues whether or not anything is switched on, and it is not in the figure unless you add it to the load.
- Runtime is an energy answer and says nothing about whether the system can carry the load at all. Whether the inverter and the battery can supply the continuous watts, and the starting surge of a motor or compressor, is a separate power question this calculation does not touch.
- Takes the bank as fully charged with nothing recharging it. No solar, generator or grid contribution is in the figure, and a bank already part-discharged when the outage began gives proportionally less than the runtime shown.
- The efficiency figure is fixed for the whole run. Capacity lost to cold, capacity faded over the bank's life, and the extra loss a lead-acid bank takes when it is discharged fast all have to be built into that one number yourself - no correction for temperature, age or discharge rate is applied.
- This is not a standby-battery compliance calculation. Fire alarm, emergency lighting and similar life-safety batteries are sized by a prescribed multi-stage calculation with its own derating and recharge requirements, set by the governing standard and the panel manufacturer's own sheet, and a general runtime figure does not substitute for it.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Runtime (hours) = (battery capacity in watt-hours x system efficiency) / load in watts

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why can't I use the full rated battery capacity?**

Inverters lose some energy converting stored DC power to usable AC power, and many battery chemistries (especially lead-acid) shouldn't be fully discharged without shortening their lifespan — the efficiency factor accounts for both.

**Does lithium vs lead-acid change this calculation?**

The formula is the same, but lithium batteries typically tolerate a much deeper discharge safely (often 90-100% vs. 50% for lead-acid), meaning more of their rated capacity is genuinely usable — factor that into your efficiency/usable-capacity assumption.

**How does this relate to solar panel sizing?**

This estimates how long stored energy lasts without recharging; the Solar Panel Array Sizing Calculator estimates how much daily energy your panels can generate to recharge the battery — a complete off-grid or backup system design uses both together.

## Related calculators

- [Solar Panel Array Sizing Calculator](https://craftquantities.com/calculators/solar-energy/solar-panel-array-sizing-calculator/)
- [Generator Fuel Runtime Calculator](https://craftquantities.com/calculators/electrical/generator-fuel-runtime-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/battery-backup-runtime-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/battery-backup-runtime-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `battery-backup-runtime-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/battery-backup-runtime-calculator.json

---
Source: https://craftquantities.com/calculators/solar-energy/battery-backup-runtime-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.