# Tiled Stair Calculator

> Tile for the treads and risers of a flight, the nosings in whole stock lengths, and the piece count that decides how long it takes.

Page: https://craftquantities.com/calculators/renovation-construction/tiled-stair-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-23, 3 published test vectors.

Tile needed for the flight: 67.3 sq ft for Steps in the flight 13 and Waste allowance 20, the page's opening figures; on the metric page, 13 and 20 give 6.18 m². Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Steps in the flight | `steps` | 13 | 13 | range 1–60 |
| Stair width | `width` | 0.9 m | 3 ft | mm, cm, m, in, ft, yd; range 0.3–3 m |
| Going, the tread depth | `going` | 250 mm | 9.75 in | mm, cm, m, in, ft, yd; range 0.1–0.6 m |
| Rise, the riser height | `rise` | 190 mm | 7.5 in | mm, cm, m, in, ft, yd; range 0.08–0.35 m |
| Nosing stock length | `nosingStock` | 2.4 m | 8 ft | mm, cm, m, in, ft, yd; range 0.3–4 m |
| Waste allowance | `wastePercent` | 20 | 20 | range 0–60 |

- **Steps in the flight**: The number of treads being tiled.
- **Stair width**: The width of the flight, which every tread and nosing has to span.
- **Going, the tread depth**: Front to back on the tread, as the tile will cover it.
- **Rise, the riser height**: The face height of one riser.
- **Nosing stock length**: The length a nosing is sold in — the whole answer for the nosing order.
- **Waste allowance**: Higher than a floor, because every piece on a stair is a cut piece.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Tile needed for the flight** | 6.18 m² |
| Tread tile | 2.93 m² |
| Riser tile | 2.22 m² |
| Allowance at 20% | 1.03 m² |
| Pieces to cut | 26 pieces |
| Nosings, 2 per stock length | 7 lengths |
| Nosing offcut, unusable | 5.1 m |

### US customary

| Result | Value |
|---|---|
| **Tile needed for the flight** | 67.3 sq ft |
| Tread tile | 31.69 sq ft |
| Riser tile | 24.38 sq ft |
| Allowance at 20% | 11.21 sq ft |
| Pieces to cut | 26 pieces |
| Nosings, 2 per stock length | 7 lengths |
| Nosing offcut, unusable | 17 ft |

## How it is worked out

26 cut pieces and 7 nosing length(s). The area is small; the piece count is the job.

The working the page shows, in order: Tread tile; Riser tile; Allowance at 20%; Pieces to cut; Nosings, 2 per stock length; Nosing offcut, unusable; then tile needed for the flight.

The method, derived in full:

- [Cut Lists and Bin Packing](https://craftquantities.com/methodology/cut-list-bin-packing/): Why sheet and length counts are a packing problem, why kerf is charged per cut, and why the optimiser is a heuristic rather than an optimum.

What this calculation does not cover:

- The piece count, not the area, is what a stair costs in time. This flight is a small area and several dozen cut pieces, every one of which has to line up with the one above it.
- Nosings are counted as whole stock lengths because a step needs a continuous piece. Where a stock length does not divide the stair width, the offcut is reported — it is usually too short for another step and is not deducted from the order.
- Nothing here sizes the stair or checks it. Rise, going and their consistency are a code matter, and tiling a flight adds a tile-and-adhesive thickness to every tread and riser, which can push an already marginal rise out of tolerance. The rise and run calculator is the page for that.
- Winders, a curved flight and a bullnose bottom step are not in this arithmetic. Each of those steps is its own shape, cut individually, and none of them takes a straight nosing.
- Adhesive, grout, primer, edge trim at the strings and the anti-slip requirement a tiled stair usually carries are all separate orders.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-23):

- Geometry: a flight's tread area is the step count times the width times the going, and its riser area the step count times the width times the rise
- Nosings are supplied in fixed stock lengths and each step needs one continuous piece, so the count is how many steps a stock length yields — not the total length divided by it
- Every tread and riser on a flight is a cut piece, which is why a stair carries a higher waste allowance than a floor of the same area

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**How much tile does a staircase need?**

A thirteen-step flight 900 mm wide with a 250 mm going and 190 mm rise is about 2.9 m² of tread and 2.2 m² of riser — roughly 5.1 m² bare, or 6.2 m² with a sensible allowance. In imperial that is about 66 sq ft. The figure that matters more is twenty-six cut pieces: the area of a small bathroom, and several times the work.

**How many nosings do I need?**

One per step, counted by how many whole stair widths a stock length yields: at the page's 900 mm (35 in) width, a 2.4 m (7 ft 10 in) length gives two, so its thirteen steps take seven lengths. That is not the total length divided by the stock length: a step needs one continuous nosing, and each 2.4 m length leaves 600 mm of unusable offcut. The same thirteen steps in 1.2 m stock take thirteen lengths, because each yields only one.

**Why is the waste allowance higher than for a floor?**

Because on a floor most tiles go down whole and only the perimeter is cut, while on a stair there is no field — every tread and every riser is cut to width, and the treads are cut to the going as well. Twenty per cent is a starting point rather than a generous one, and a winder or an out-of-square flight wants more.

**Does tiling change the step heights?**

Yes, and it is worth checking before ordering. Tile and adhesive add perhaps 12 to 15 mm to each tread and the same to each riser face. Adding it to every step keeps the rises equal; adding it to the treads but not the bottom floor makes the first step shorter than the rest by that thickness, which is exactly the inconsistency stair regulations exist to prevent.

## Related calculators

- [Floor & Wall Tile Calculator](https://craftquantities.com/calculators/renovation-construction/floor-tile-calculator/)
- [Tile Adhesive Calculator](https://craftquantities.com/calculators/renovation-construction/tile-adhesive-calculator/)
- [Grout Calculator](https://craftquantities.com/calculators/renovation-construction/grout-calculator/)
- [Stair Rise & Run Calculator](https://craftquantities.com/calculators/renovation-construction/stair-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/tiled-stair-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/tiled-stair-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `tiled-stair-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/tiled-stair-calculator.json

---
Source: https://craftquantities.com/calculators/renovation-construction/tiled-stair-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.