# Stair Stringer Drop Cut Calculator

> How much to take off the bottom of a cut stringer so the first step finishes level with all the others once the treads and the floor finishes are on.

Page: https://craftquantities.com/calculators/renovation-construction/stair-drop-cut-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Drop cut at the base of the stringer: 0.5 in for Rise Measured to the Bare Deck 9.5 ft, the page's opening figures; on the metric page, 2.9 m gives 13 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Rise Measured to the Bare Deck | `measuredRise` | 2.9 m | 9.5 ft | mm, cm, m, in, ft, yd; range 0.4–6 m |
| Risers in the Flight | `riserCount` | 16 | 16 | range 2–30 |
| Finished Tread Thickness | `treadThickness` | 25 mm | 1 in | mm, cm, m, in, ft, yd; range 0.005–0.08 m |
| Starter Tread Thickness | `starterTreadThickness` | 25 mm | 1 in | mm, cm, m, in, ft, yd; range 0.005–0.1 m |
| Lower Floor Build-Up | `lowerFloorBuildUp` | 12 mm | 0.5 in | mm, cm, m, in, ft, yd; range 0–0.1 m |
| Upper Landing Build-Up | `upperLandingBuildUp` | 12 mm | 0.5 in | mm, cm, m, in, ft, yd; range 0–0.1 m |

- **Rise Measured to the Bare Deck**: From the surface the stringer will stand on, up to the bare landing deck.
- **Risers in the Flight**: The number of risers the flight will have, floor to floor.
- **Finished Tread Thickness**: The thickness of the treads that will sit on the stringer cuts.
- **Starter Tread Thickness**: The bottom tread's thickness, where it differs from the rest.
- **Lower Floor Build-Up**: Finish going down at the base of the stair after the stringer is set.
- **Upper Landing Build-Up**: Finish going down on the landing above after the stringer is set.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Drop cut at the base of the stringer** | 13 mm |
| Uniform riser height for the finished flight | 181.25 mm |
| Total finished rise | 2.9 m |
| First riser as built | 181.25 mm |
| Second riser as built | 181.25 mm |
| Top riser as built | 181.25 mm |
| Variation this introduces across the flight | 0 mm |

### US customary

| Result | Value |
|---|---|
| **Drop cut at the base of the stringer** | 0.5 in |
| Uniform riser height for the finished flight | 7.13 in |
| Total finished rise | 9.5 ft |
| First riser as built | 7.13 in |
| Second riser as built | 7.13 in |
| Top riser as built | 7.13 in |
| Variation this introduces across the flight | 0 in |

## How it is worked out

Take 13.0 mm off the bottom horizontal cut, keeping the cut square and the bearing full. The tread arrangement entered introduces 0.0 mm of variation across the flight, inside the 9.5 mm the model codes allow.

The working the page shows, in order: Uniform riser height for the finished flight; Total finished rise; First riser as built; Second riser as built; Top riser as built; Variation this introduces across the flight; then drop cut at the base of the stringer.

The method, derived in full:

- [Stair Geometry, Ramps and Guarding](https://craftquantities.com/methodology/stair-geometry-and-guarding/): Why you choose the number of risers rather than their height, why the spread across a whole flight is held to three-eighths of an inch, and why a cable railing has to be checked deflected rather than at rest.

What this calculation does not cover:

- Cut stringers carried on their horizontal cuts. Housed stringers with wedged treads set the tread position from the housing instead, and the adjustment is made in the routing rather than at the base.
- Assumes the stringer's top cut is set from the bare landing deck. Where the stair hangs from a header at a fixed height instead, the top attachment absorbs part of this and has to be set out separately.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Derived geometry, and a standard carpentry layout rule rather than a code provision: the stringer's first riser is cut short by the thickness of the tread that will sit on it, less any floor finish that goes down after the stair is set
- IRC R311.7.5.1 and IBC 1011.5.4 set the tolerance the result is judged against — no more than 3/8 in (9.5 mm) between the greatest and smallest riser in a flight

The site's pages for the documents these name:

- [International Residential Code](https://craftquantities.com/standards/icc/irc/)
- [International Building Code](https://craftquantities.com/standards/icc/ibc/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does the bottom riser need cutting shorter at all?**

Because every step in the flight except the first gets a tread both above and below it, so the tread thicknesses cancel out. The bottom step has a tread on top and the floor underneath, so its riser is taller than the layout by exactly the thickness of that tread — and the cure is to take the same amount off the foot of the stringer before it is fixed.

**What happens if I drop the stringer and then the floor finish goes down anyway?**

The bottom riser ends up short by the thickness of that finish, and if it is a tiled floor on a bed the shortfall will exceed the tolerance on its own. This is the commonest single-step failure on an inspection, and it is why the drop cut is the tread thickness less the finish rather than the tread thickness alone.

**My starter tread is thicker than the rest. Where does the difference go?**

It moves into the second riser and out of the top one, because the whole cut pattern above the first step shifts by the difference. A 50 mm starter under 28 mm treads throws 22 mm into two risers, which is more than twice the variation the codes allow, so the extra thickness has to be absorbed by re-cutting the stringer rather than by hoping nobody measures.

**Should I measure the total rise before or after the finishes?**

Measure what exists, then add what is coming. Subfloor to bare landing deck is a real dimension you can put a tape on; finished floor to finished landing is a prediction. Entering the measurement with the two build-ups separately means the layout follows the finishes even when they change late, which they routinely do.

## Related calculators

- [Stair Rise & Run Calculator](https://craftquantities.com/calculators/renovation-construction/stair-calculator/)
- [Stair Riser Spread Tolerance Checker](https://craftquantities.com/calculators/renovation-construction/riser-spread-tolerance-checker/)
- [Structural Steel Stair Stringer Length Calculator](https://craftquantities.com/calculators/materials-quantities/steel-stair-stringer-length-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/stair-drop-cut-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/stair-drop-cut-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `stair-drop-cut-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/stair-drop-cut-calculator.json

---
Source: https://craftquantities.com/calculators/renovation-construction/stair-drop-cut-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.