Number of risers needed: 15 risers for Total Rise 9 ft, Target Riser Height 7.25 in and Planned Tread Depth 10.25 in, the page's opening figures; on the metric page, 2.8 m, 18.5 cm and 26 cm give 15 risers. Source: Australia.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Total Rise (floor to floor) | `totalRise` | 2.8 m | 9 ft | mm, cm, m, in, ft, yd; range 0.01–6 m |
| Target Riser Height | `targetRiser` | 18.5 cm | 7.25 in | mm, cm, m, in, ft, yd; range 0.01–0.2032 m |
| Planned Tread Depth (Going) | `actualTreadDepth` | 26 cm | 10.25 in | mm, cm, m, in, ft, yd; range 0.01–0.4 m |
| Building Code Reference | `buildingCode` | US — IRC 2024 (max 7.75 in riser / min 10 in tread) | US — IRC 2024 (max 7.75 in riser / min 10 in tread) | `irc`, `uk`, `au`, `ca`, `generic` |
| Headroom Over the Flight | `headroom` | 2.032 m | 6.66667 ft | mm, cm, m, in, ft, yd; range 1.5–3 m |
| Upper Floor Depth at the Opening | `upperFloorDepth` | 30 cm | 11.75 in | mm, cm, m, in, ft, yd; range 0–1 m |

- **Total Rise (floor to floor)**: The total vertical height the staircase needs to climb.
- **Target Riser Height**: A comfortable target, not a code limit: about 175–190 mm (6.9–7.5 in) suits most house stairs.
- **Planned Tread Depth (Going)**: The horizontal depth of each tread (the 'going') you plan to build, front edge to front edge.
- **Building Code Reference**: Which building code to check your stair design against.
- **Headroom Over the Flight**: The clear height you want above the nosing line, which sets how long the floor opening must be.
- **Upper Floor Depth at the Opening**: From the finished upper floor down to the ceiling under it, at the edge of the opening.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Number of risers needed** | 15 risers |
| Actual riser height | 186.67 mm |
| Number of treads (steps) | 14 treads |
| Recommended tread depth (comfort formula) | 261.67 mm |
| Code max riser height (US IRC 2024) | 196.85 mm |
| Code min tread depth (US IRC 2024) | 254 mm |
| Total run of the flight | 3.64 m |
| Floor opening for the headroom | 3.25 m |

### US customary

| Result | Value |
|---|---|
| **Number of risers needed** | 15 risers |
| Actual riser height | 7.2 in |
| Number of treads (steps) | 14 treads |
| Recommended tread depth (comfort formula) | 10.6 in |
| Code max riser height (US IRC 2024) | 7.75 in |
| Code min tread depth (US IRC 2024) | 10 in |
| Total run of the flight | 11.96 ft |
| Floor opening for the headroom | 10.88 ft |

## How it is worked out

WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 7.35 in (187 mm) and tread depth 10.24 in (260 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides.

The working the page shows, in order: Actual riser height; Number of treads (steps); Recommended tread depth (comfort formula); Code max riser height (US IRC 2024); Code min tread depth (US IRC 2024); Total run of the flight; Floor opening for the headroom; then number of risers needed.

The method, derived in full:

- [Stair Geometry, Ramps and Guarding](https://craftquantities.com/methodology/stair-geometry-and-guarding/): Why you choose the number of risers rather than their height, why the spread across a whole flight is held to three-eighths of an inch, and why a cable railing has to be checked deflected rather than at rest.

The equations it runs, in the open formula library:

- Formula: [n = max(1, round(H / rₜ))](https://craftquantities.com/formulas/stairs/#riser-count)
- Formula: [R = H / n](https://craftquantities.com/formulas/stairs/#riser-height)
- Formula: [G = c − 2 × R](https://craftquantities.com/formulas/stairs/#comfort-going)

What this calculation does not cover:

- Checks riser height and tread depth — and, under Approved Document K, the minimum rise, maximum going, 42° pitch and 2R + G as well. Headroom, handrail height and graspability, guard height, nosing projection and stair width are not checked.
- Under Australia's NCC it checks the rise, the going, 2R + G and the 2 to 18 risers a flight may have; under Canada's National Building Code, the rise, the run and the 3.7 m (12.14 ft) a private flight may rise. Neither code's landings, balustrade or guard heights, handrails, headroom or tread construction are checked.
- Assumes a single continuous flight — no landing requirements are evaluated.
- The floor opening is geometry on a straight flight: the run over which the nosing line plus the headroom you enter would strike the underside of the upper floor, measured along the flight from its top. It is not a headroom check, and it ignores a bulkhead, a beam or a trimmer deeper than the floor depth entered.
- Winder and spiral stairs follow different rules that this calculator does not model.
- Local amendments to the model code frequently differ; confirm with your building department.

A professional must decide:

- Local amendments to the model code frequently differ; confirm with your building department.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-10-31):

- Comfortable stair proportion rule of thumb: 2 x riser height + tread depth = 24-25 inches; a riser of about 175–190 mm (6.9–7.5 in) is a comfortable target that sits inside all four codes this page checks
- US: IRC 2024 R311.7.5 — maximum riser height 7.75 in, minimum tread depth (going) 10 in
- UK: Approved Document K (2013), Section 1, Table 1.1 — a private stair's rise 150–220 mm and going 220–300 mm, pitch at most 42°, and twice the rise plus the going between 550 and 700 mm
- Australia: ABCB Housing Provisions Standard, Part 11.2, clause 11.2.2 and Table 11.2.2a, called up by NCC Volume Two for houses; the same table in NCC 2022 and NCC 2025. A stairway other than a spiral stair has risers of 115–190 mm, goings of 240–355 mm and a slope relationship 2R + G of 550–700 mm; each flight has not more than 18 and not less than 2 risers (11.2.2(1)(a)); goings and risers are constant through a flight, within 5 mm between neighbours and 10 mm across the flight (11.2.2(1)(c)); and risers have no opening a 125 mm sphere can pass through (11.2.2(1)(d)). Under 11.2.2(2), a stairway serving only non-habitable rooms such as attics and storerooms that are not used on a regular or daily basis may use Table 11.2.2b instead: riser 130–225 mm, going 215–355 mm and 2R + G 540–700 mm. NCC Volume One, clause D3D14 and Table D3D14, gives a public stairway in other buildings a going of 250–355 mm with the same risers and 2R + G <https://ncc.abcb.gov.au/editions/ncc-2025/adopted/housing-provisions/11-safe-movement-and-access/part-112-stairway-and-ramp-construction>
- Canada: National Building Code of Canada 2020, Volume 2, Division B, Section 9.8, for a private stair (one serving a single dwelling unit, a house with a secondary suite, or a garage serving either): rise 125–200 mm (Article 9.8.4.1, Table 9.8.4.1), run 255–355 mm (Article 9.8.4.2, Table 9.8.4.2), each tread's depth between its run and its run plus 25 mm (Sentence 9.8.4.2.(2)), risers and runs uniform within 5 mm between neighbours and 10 mm across a flight (Article 9.8.4.4), no flight more than 3.7 m high (Article 9.8.3.3), and 1 950 mm of clear height over a stair serving a single dwelling unit (Sentence 9.8.2.2.(3)). A public stair has a rise of 125–180 mm and a run of at least 280 mm. Provinces and territories adopt the NBC with amendments of their own, so check the edition in force where you build <https://doi.org/10.4224/w324-hv93>

The site's pages for the documents these name:

- [International Residential Code](https://craftquantities.com/standards/icc/irc/)
- [Approved Documents to the Building Regulations (England)](https://craftquantities.com/standards/uk-gov/uk-approved-documents/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is the actual riser height different from my target?**

All risers in a staircase must be equal height by code, so the total rise is divided evenly by a whole number of risers — the result is usually close to, but not exactly, your target.

**Why is tread count one less than riser count?**

The top riser is the floor you're stepping onto, which doesn't need its own tread — a staircase with 15 risers has 14 individual treads plus the top floor.

**Is this a substitute for checking local building code?**

No — this checks a few dimensional limits from one code, riser height and tread depth among them. Under Approved Document K it also checks the minimum rise, maximum going, pitch and 2R + G; under Australia's NCC, 2R + G and the risers in a flight too; under Canada's National Building Code, the height of the flight. Full stair code compliance also covers headroom, handrail height and graspability, guard requirements, and nosing — always verify the complete set of requirements with your local building department before building.

**What do Australia's NCC and Canada's National Building Code set for a house stair?**

For a house stair, the NCC sets risers of 115 to 190 mm (4.53 to 7.48 in) and Canada's National Building Code 125 to 200 mm (4.92 to 7.87 in). The NCC Housing Provisions, in Table 11.2.2a, apply that riser range to a stairway other than a spiral stair, with goings of 240 to 355 mm (9.45 to 13.98 in) and twice the rise plus the going between 550 and 700 mm (21.65 to 27.56 in), and no fewer than 2 and no more than 18 risers in a flight. Canada's code gives a private stair, one serving a single dwelling unit, that rise with a run of 255 to 355 mm (10.04 to 13.98 in), and no flight may rise more than 3.7 m (12.14 ft). The codes disagree at the edges: a 197 mm (7.75 in) riser, the most the IRC allows, is over the NCC's 190 mm (7.48 in) and inside the NBC's 200 mm (7.87 in), so check a stair against the code where it is built.

**What's the difference between 'recommended tread depth' and 'planned tread depth'?**

Recommended tread depth is derived from the 2R+T=25in comfort formula based on your actual riser height — it's a suggestion. Planned tread depth is what you enter as your real design, which is what actually gets checked against the building code's minimum.

## Related calculators

- [L-Shaped and U-Shaped Stair Calculator (Landings, Winders, Stringers, Treads and Risers)](https://craftquantities.com/calculators/materials-quantities/landing-stair-calculator/)
- [Stair Stringer Calculator (Cuts, Floor Opening, Treads and Risers)](https://craftquantities.com/calculators/materials-quantities/stair-stringer-calculator/)
- [Winder Stair Calculator (Kite, Balanced and Dancing Winders, Quarter and Half Turns: Each Set Out)](https://craftquantities.com/calculators/materials-quantities/winder-stair-calculator/)
- [Spiral Staircase Calculator (Spiral, Helical and Curved Stairs: Treads, Going, Headroom and Handrail)](https://craftquantities.com/calculators/materials-quantities/spiral-staircase-calculator/)
- [Ship's Ladder and Alternating Tread Stair Calculator (Loft and Attic Stairs: Risers, Pitch and Stringers)](https://craftquantities.com/calculators/materials-quantities/ship-ladder-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/stair-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/stair-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `stair-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/stair-calculator.json

---
Source: https://craftquantities.com/calculators/renovation-construction/stair-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.