# Stair Riser Spread Tolerance Checker

> Measure the flight, enter the tallest and the shortest riser, and see how much of the permitted variation the difference between them uses up.

Page: https://craftquantities.com/calculators/renovation-construction/riser-spread-tolerance-checker/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-08-30, 2 published test vectors.

Spread between tallest and shortest riser: 0.25 in for Tallest Measured Riser 7.5 in, Shortest Measured Riser 7.25 in and Permitted Variation 0.38 in, the page's opening figures; on the metric page, 190 mm, 183 mm and 9.53 mm give 7 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Tallest Measured Riser | `tallestRiser` | 190 mm | 7.5 in | mm, cm, m, in, ft, yd; range 0.1–0.3 m |
| Shortest Measured Riser | `shortestRiser` | 183 mm | 7.25 in | mm, cm, m, in, ft, yd; range 0.1–0.3 m |
| Permitted Variation | `permittedVariation` | 9.525 mm | 0.375 in | mm, cm, m, in, ft, yd; range 0.002–0.0125 m |
| Risers in the Flight | `riserCount` | 16 | 16 | range 2–40 |
| Total Rise of the Flight | `totalRise` | 3 m | 10 ft | mm, cm, m, in, ft, yd; range 0.4–6 m |

- **Tallest Measured Riser**: The largest riser you measured anywhere in the flight.
- **Shortest Measured Riser**: The smallest riser you measured anywhere in the flight.
- **Permitted Variation**: The variation your adopted code allows across one flight.
- **Risers in the Flight**: How many risers the flight contains from floor to floor.
- **Total Rise of the Flight**: Finished floor to finished floor, measured over the whole flight.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Spread between tallest and shortest riser** | 7 mm |
| Permitted variation for this flight | 9.53 mm |
| Margin left before the limit | 2.52 mm |
| Uniform riser height for this flight | 187.5 mm |
| Tallest riser above the uniform height | 2.5 mm |
| Shortest riser below the uniform height | 4.5 mm |

### US customary

| Result | Value |
|---|---|
| **Spread between tallest and shortest riser** | 0.25 in |
| Permitted variation for this flight | 0.38 in |
| Margin left before the limit | 0.12 in |
| Uniform riser height for this flight | 7.5 in |
| Tallest riser above the uniform height | 0 in |
| Shortest riser below the uniform height | 0.25 in |

## How it is worked out

The riser spread measured is 2.5 mm inside the variation entered. Re-measure after the floor finishes go down at both ends, because that is when a flight that was inside the limit most often stops being. Matching the figures quoted is not compliance. The rest of the requirement, and the installed work, are outside what this page can see.

The working the page shows, in order: Permitted variation for this flight; Margin left before the limit; Uniform riser height for this flight; Tallest riser above the uniform height; Shortest riser below the uniform height; then spread between tallest and shortest riser.

The method, derived in full:

- [Stair Geometry, Ramps and Guarding](https://craftquantities.com/methodology/stair-geometry-and-guarding/): Why you choose the number of risers rather than their height, why the spread across a whole flight is held to three-eighths of an inch, and why a cable railing has to be checked deflected rather than at rest.

What this calculation does not cover:

- Works from the two extremes you supply. It cannot find an outlier you did not measure, and the rule it applies is flight-wide rather than pairwise.
- Riser height is one of several stair checks. Tread depth uniformity, nosing projection, headroom and handrail geometry are all separately enforced and a flight can pass here and fail those.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-08-30):

- IRC R311.7.5.1 and IBC 1011.5.4: the greatest riser height within a flight shall not exceed the smallest by more than 3/8 in (9.5 mm) — a flight-wide rule, measured between the extremes rather than between neighbours
- Other jurisdictions set the figure differently, which is why the permitted variation is entered rather than fixed: Approved Document K and the National Construction Code both express riser uniformity in their own terms
- Arithmetic only: spread = tallest measured riser − shortest measured riser, compared against the variation you enter

The site's pages for the documents these name:

- [International Residential Code](https://craftquantities.com/standards/icc/irc/)
- [Approved Documents to the Building Regulations (England)](https://craftquantities.com/standards/uk-gov/uk-approved-documents/)
- [International Building Code](https://craftquantities.com/standards/icc/ibc/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Is the rule about neighbouring steps or the whole flight?**

The whole flight. Both North American model codes compare the greatest riser in the flight with the smallest, wherever in the run those two happen to be, so a flight that creeps by half a millimetre a step can accumulate a failure without any two adjacent steps looking different. That is also why measuring only the ones that feel wrong is unreliable.

**Why do uneven risers matter so much when the difference is a few millimetres?**

Because descending a stair is largely done without looking. After two or three steps a person's gait has locked on to a rhythm and their foot is placed where the previous riser height predicts, so a step that arrives early or late produces a stumble at the point where the body has the least chance to recover. It is a leading cause of stair falls and it is why inspectors take the tolerance literally.

**My flight fails at the bottom step only. What is the fix?**

Almost always a floor finish that was not allowed for when the stringer was cut. If the lower floor gained a build-up after the stair was set, the bottom riser is short by that thickness; if the stringer was dropped by the full tread thickness and the finish went on anyway, it is short by the difference. Packing the stringer base or re-cutting it is the usual remedy, and the drop-cut page works out by how much.

## Related calculators

- [Stair Rise & Run Calculator](https://craftquantities.com/calculators/renovation-construction/stair-calculator/)
- [Stair Stringer Drop Cut Calculator](https://craftquantities.com/calculators/renovation-construction/stair-drop-cut-calculator/)
- [Spiral Stair Headroom Clearance Calculator](https://craftquantities.com/calculators/materials-quantities/spiral-stair-headroom-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/riser-spread-tolerance-checker` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/riser-spread-tolerance-checker` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `riser-spread-tolerance-checker`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/riser-spread-tolerance-checker.json

---
Source: https://craftquantities.com/calculators/renovation-construction/riser-spread-tolerance-checker/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.