# Floor & Wall Tile Calculator

> Count tiles and boxes for a floor or wall, with the waste factor the lay pattern actually needs.

Page: https://craftquantities.com/calculators/renovation-construction/floor-tile-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.2, sources checked 2026-09-17, 4 published test vectors.

Tiles required: 36 tiles for Area to tile 130 sq ft, Tile length 24 in and Tile width 24 in, the page's opening figures; on the metric page, 12 m², 600 mm and 600 mm give 37 tiles. Sources are cited below.

## Key facts

- The TCNA Handbook and BS 5385 recommend a 5-10% waste allowance for tile laid straight and 15-20% for a diagonal or herringbone pattern. (source: TCNA Handbook and BS 5385 waste ranges: TCNA Handbook and BS 5385 both recommend 5-10% waste for a straight lay and 15-20% for a diagonal or herringbone pattern)
- Tile is sold by the box, and the area one box covers varies with the tile format, so box coverage comes from the supplier's data rather than a fixed figure. (source: Tile box coverage, supplier data: Tile is sold by the box; box coverage varies by format and must come from the supplier)
- ANSI A108.02 section 4.3.8.2 caps a running-bond offset at 33% where the side being offset is over 18 in (457 mm) nominal, unless the tile manufacturer specifies otherwise. ([IMI on ANSI A108.02 section 4.3.8.2](https://info.imiweb.org/blog/large-format-tile-dealing-with-lippage): Large Format Tile: Dealing with Lippage, International Masonry Institute)

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Area to tile | `area` | 12 m² | 130 sq ft | m2, ft2, mm2, in2; range 0.01–5000 m² |
| Tile length | `tileLength` | 600 mm | 24 in | mm, cm, m, in, ft, yd; range 0.01–3 m |
| Tile width | `tileWidth` | 600 mm | 24 in | mm, cm, m, in, ft, yd; range 0.01–3 m |
| Lay pattern | `pattern` | Straight / stack bond — 10% waste | Straight / stack bond — 10% waste | `straight`, `brick`, `diagonal`, `herringbone` |
| Tiles per box | `tilesPerBox` | 6 | 6 | range 1–200 |

- **Area to tile**: Net area of floor or wall.
- **Tile length**: Long side of the tile.
- **Tile width**: Short side of the tile.
- **Lay pattern**: How the tiles are laid.
- **Tiles per box**: From the supplier's data.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Tiles required** | 37 tiles |
| Boxes to order | 7 boxes |
| Tiles before waste | 33.33 tiles |
| Waste applied | 10 % |
| Area covered by the boxes | 15.12 m² |
| Spare after the job | 5 tiles |

### US customary

| Result | Value |
|---|---|
| **Tiles required** | 36 tiles |
| Boxes to order | 6 boxes |
| Tiles before waste | 32.5 tiles |
| Waste applied | 10 % |
| Area covered by the boxes | 144 sq ft |
| Spare after the job | 0 tiles |

- Allowance in the figure: Pattern waste (10%).

## Formula with your numbers

1. **Divide the area by one tile**: 130 sq ft ÷ (24 in × 24 in) = 32.5 tiles
2. **Add the pattern waste and round up**: 32.5 tiles + 10 % waste, rounded up = 36 tiles
3. **Round up to whole boxes**: 36 tiles ÷ 6 a box, rounded up = 6 boxes

Worked on the figures the page opens on; the page re-works each step on the reader's own.

## How to calculate floor & wall tile in 3 steps

1. **Divide the area by one tile**: Divide the area to tile by the face of one tile, its length times its width, for the tiles that cover the floor before any cuts.
2. **Add the pattern waste and round up**: Add the waste for the lay pattern, 10% straight up to 20% herringbone, then round up to whole tiles.
3. **Round up to whole boxes**: Divide the tiles by the number in one box and round up to whole boxes, ordered from one batch.

## Tiles for common floor areas

Page defaults, not your figures above.

| Floor area | Tiles required |
|---|---|
| 25 sq ft (2.32 m²) | 7 tiles |
| 50 sq ft (4.65 m²) | 14 tiles |
| 100 sq ft (9.29 m²) | 28 tiles |
| 150 sq ft (13.94 m²) | 42 tiles |
| 200 sq ft (18.58 m²) | 55 tiles |
| 300 sq ft (27.87 m²) | 83 tiles |
| 5 m² (53.82 sq ft) | 16 tiles |
| 10 m² (107.64 sq ft) | 31 tiles |
| 15 m² (161.46 sq ft) | 46 tiles |
| 20 m² (215.28 sq ft) | 62 tiles |
| 30 m² (322.92 sq ft) | 92 tiles |

## How it is worked out

Keep the spare tiles. A batch-matched replacement in five years is worth more than the box it came in.

The working the page shows, in order: Boxes to order; Tiles before waste; Waste applied; Area covered by the boxes; Spare after the job; then tiles required.

The method, derived in full:

- [Quantity, Waste and Rounding](https://craftquantities.com/methodology/quantity-waste-and-rounding/): Why a material count is a ceiling function rather than a division, and why the waste factor — not the geometry — carries the risk.

What this calculation does not cover:

- Nothing checks that the tile and the pattern belong together. A tile with any edge of 15 in (about 380 mm) or more falls under a tighter substrate flatness rule — TCNA asks for 1/8 in in 10 ft — and the offset on a long plank is held to roughly a third of its length, because a half-bond sets the neighbouring tile's high point against your tile's crown and produces lippage. This will happily return a herringbone count for a 1200 mm plank over a floor that cannot take it.
- Movement joints sit outside the count. The same TCNA and BS 5385 documents cited above for the waste figures also call for a soft joint at every perimeter and wall abutment, around columns and fixed penetrations, and across the field at intervals — roughly 8 to 10 m indoors, and much closer over a heated screed or outside. Those joints take sealant and a profile rather than grout, and a floor tiled hard into its walls tents at the first hot spell.

## Sources

As the calculator cites them (sources checked 2026-09-17):

- TCNA Handbook and BS 5385 both recommend 5-10% waste for a straight lay and 15-20% for a diagonal or herringbone pattern
- Tile is sold by the box; box coverage varies by format and must come from the supplier

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does a diagonal lay waste so much more?**

Because every perimeter tile is cut at 45°, and the triangular offcut from one edge almost never fits anywhere else. On a straight lay the offcut from one wall often completes the opposite wall. That is the whole difference between a 10% and an 18% allowance.

**Should I order extra beyond the waste allowance?**

Yes — a box. Dye lots vary between production batches, so a tile bought in three years will not match. One spare box, stored flat and dry, is the difference between an invisible repair and re-tiling a room after a leak.

**Do I deduct doorways and fixtures?**

Deduct large permanent things — a bath, a fitted island. Do not deduct doorways or small obstructions: you will cut a tile to fit around them anyway, and the deduction removes material you still need.

**How many boxes of 24 in tile does a 130 sq ft floor take?**

6 boxes of six, 36 tiles, for 130 sq ft (12.1 m²) of 24 × 24 in (610 mm) tile laid straight. One tile covers 4 sq ft, so 32.5 tiles cover the floor; the 10% straight-lay waste makes 35.75, rounded up to 36, and 36 over six a box is six boxes. In metric, 12 m² of 600 × 600 mm tile takes 37 tiles in 7 boxes, because a 600 mm tile is slightly smaller than a 24 in one.

**Where do the pattern waste percentages come from?**

From the ranges the TCNA Handbook and BS 5385 give: 5-10% waste for a straight lay and 15-20% for a diagonal or herringbone pattern. This page takes 10% for a straight or stack bond, 12% for a brick offset, 18% for a diagonal and 20% for a herringbone, applied to the tile count before it is rounded up. A small room with many cuts sits at the top of each range.

**Does a large tile need a flatter floor?**

Yes: once any edge of the tile reaches 15 in (about 380 mm), TCNA asks for the substrate to be flat to 1/8 in in 10 ft (about 3 mm in 3 m). The offset on a long plank is also held to roughly a third of its length, because a half-bond sets the high point of one bowed tile against its neighbour's end. This page counts tiles and checks neither, so level the floor before you set a large format.

**Do I need movement joints in a tiled floor?**

Yes: the same TCNA and BS 5385 documents call for a soft joint at every perimeter and wall abutment, around columns and fixed penetrations, and across the field roughly every 8 to 10 m (26 to 33 ft) indoors, closer over a heated screed or outside. Those joints take a sealant and a profile rather than grout, and this count leaves them out; a floor tiled hard into its walls can tent in the first hot spell.

## Related calculators

- [Tile Layout Calculator](https://craftquantities.com/calculators/renovation-construction/tile-layout-calculator/)
- [Tile & Grout Calculator](https://craftquantities.com/calculators/renovation-construction/tile-grout-calculator/)
- [Thinset & Tile Adhesive Calculator](https://craftquantities.com/calculators/renovation-construction/thinset-mortar-calculator/)
- [Diagonal Tile Layout 45° Corner Cut Waste Calculator](https://craftquantities.com/calculators/materials-quantities/diagonal-tile-corner-waste-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/floor-tile-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/floor-tile-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `floor-tile-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/floor-tile-calculator.json

---
Source: https://craftquantities.com/calculators/renovation-construction/floor-tile-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.