# Pump Drain Time Calculator

> Hours to drain a pool, flooded basement or tank — from the pump's real operating point on its hose, not the zero-head number on the box.

Page: https://craftquantities.com/calculators/pools-water/pump-drawdown-time-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 4 published test vectors.

Estimated drain time: 10.4 hours for Water volume to remove 13210 gal, Pump maximum head 26 ft and Vertical lift 6.5 ft, the page's opening figures; on the metric page, 50 m³, 8 m and 2 m give 10.6 hours. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Water volume to remove | `volume` | 50 m³ | 13210 gal | l, gal, m3, ft3, yd3; range 0.1–5000000 L |
| Pump rated flow (at zero head) | `ratedFlow` | 200 L/min | 53 gal/min | lpm, lps, gpm; range 0.1–5000 L/min |
| Pump maximum head | `maxHead` | 8 m | 26 ft | mm, cm, m, in, ft, yd; range 0.01–100 m |
| Vertical lift | `staticLift` | 2 m | 6.5 ft | mm, cm, m, in, ft, yd; range 0–50 m |
| Hose inside diameter | `hoseDia` | 25 mm | 1 in | mm, cm, m, in, ft, yd; range 0.01–0.15 m |
| Hose length | `hoseLength` | 10 m | 33 ft | mm, cm, m, in, ft, yd; range 0.01–200 m |

- **Water volume to remove**: The volume of water to move — a pool, a flooded floor, a tank.
- **Pump rated flow (at zero head)**: The headline flow on the pump's box or plate — measured with no lift and no hose.
- **Pump maximum head**: The lift at which the pump's flow falls to zero — on the same plate as the rated flow.
- **Vertical lift**: Height from the water surface up to the hose outlet.
- **Hose inside diameter**: The inside bore of the discharge hose — the single most sensitive number here.
- **Hose length**: Total discharge hose length, including the part lying flat.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Estimated drain time** | 10.6 hours |
| Delivered flow at the operating point | 78.26 L/min |
| Share of rated flow surviving lift and hose | 39.13 % |
| Friction head in the hose | 2.87 m |
| Total dynamic head | 4.87 m |

### US customary

| Result | Value |
|---|---|
| **Estimated drain time** | 10.4 hours |
| Delivered flow at the operating point | 21.14 gal/min |
| Share of rated flow surviving lift and hose | 39.88 % |
| Friction head in the hose | 9.13 ft |
| Total dynamic head | 15.63 ft |

- Confidence: medium.

## How it is worked out

Built on a linearised pump curve and Hazen–Williams hose friction (C = 150). A manufacturer's published curve, where you have one, governs.

The working the page shows, in order: Delivered flow at the operating point; Share of rated flow surviving lift and hose; Friction head in the hose; Total dynamic head; then estimated drain time.

The method, derived in full:

- [Seepage, Drawdown and Dewatering](https://craftquantities.com/methodology/seepage-and-dewatering/): Why permeability varies over ten orders of magnitude and therefore dominates every seepage answer, why the radius of influence is an empirical fudge rather than a measurement, and why dewatering settles the neighbours.

What this calculation does not cover:

- The vertical lift is held constant for the whole job and no water is assumed to arrive while the pump runs. In a pool the lift grows as the level drops; in a flooded basement groundwater, rain or a live leak keeps feeding the space. Real time to empty runs longer than this figure, and where inflow matches the delivered flow the level never falls at all.
- Only straight hose length is charged for friction. Fittings, quick-couplers, a strainer or foot valve, a check valve, kinks, a partly closed discharge and any suction-side pipework all add head that is not in this number. Hazen-Williams with C = 150 is an empirical fit for smooth pipe carrying clean water — silt, debris, cold water or a ribbed corrugated hose all move the real loss away from it, and the formula is at its weakest in bores this small.
- The pump is modelled as a straight line between the two figures on its plate. Where you have the manufacturer's published curve, that curve governs. Nothing here checks that the pump can prime at your suction lift, that it will hold prime as the water shallows, or that it is rated to run continuously for the hours reported — most utility pumps also stop drawing well before the floor is dry.
- This is a time estimate, not a decision to empty the pool. It says nothing about hydrostatic uplift on an empty shell, liner shrinkage or collapse, or the groundwater conditions that decide whether a pool can safely be drained at all. Those questions belong to the pool builder and to the shell's own relief arrangements.
- Where the water goes is outside this calculation. Discharging chlorinated, salt or silt-laden water to a storm drain, a watercourse or adjoining land is regulated in most places, and the receiving drain's capacity may be far below the flow reported here. Confirm the disposal route with the local water authority before running the pump.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Hazen–Williams empirical head-loss formula, h_f = 10.67·L·Q^1.852 / (C^1.852·d^4.87), with C = 150 for smooth plastic/rubber hose — standard engineering hydraulics form (SI units)
- Pump performance approximated as a linear curve from rated flow at zero head to zero flow at rated maximum head — the standard first approximation for small utility and submersible pumps; the manufacturer's published curve governs where one exists

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is the drain time so much longer than volume ÷ rated flow?**

The rated flow is measured at zero head — pump sitting in water, no hose, no lift. Real jobs have both, and the pump slides down its curve until the head it can still produce matches what the lift and the hose friction demand. That operating point, not the box number, sets the time.

**What helps more: a bigger pump or a bigger hose?**

Usually the hose. Friction loss grows with almost the fifth power of shrinking bore, so stepping a 25 mm hose up to 38 mm cuts friction to roughly a seventh. A bigger pump pushed through the same narrow hose spends most of its extra power making friction.

**The result says 0 hours. Is the pool already empty?**

No — 0 here means never. Your vertical lift meets or exceeds the pump's maximum head, so no water arrives at the outlet. The confidence note says so when it happens.

**Does the last few centimetres of water drain at the same rate?**

No. As the level drops the lift grows slightly, and most pumps also lose prime in very shallow water. The final draw-down is slower than this average, and utility pumps typically leave a few millimetres behind.

## Related calculators

- [Pool Volume Calculator (Rectangular, Round, Oval or Kidney)](https://craftquantities.com/calculators/pools-water/pool-volume-calculator/)
- [Sump Pump GPM Calculator](https://craftquantities.com/calculators/plumbing-hvac/sump-pump-gpm-calculator/)
- [Hydronic Circulator Pump Head Loss Calculator](https://craftquantities.com/calculators/materials-quantities/circulator-pump-head-loss-calculator/)
- [Dewatering Well Yield Calculator (Dupuit-Forchheimer)](https://craftquantities.com/calculators/heavy-civil/dewatering-well-yield-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/pump-drawdown-time-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/pump-drawdown-time-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `pump-drawdown-time-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/pump-drawdown-time-calculator.json

---
Source: https://craftquantities.com/calculators/pools-water/pump-drawdown-time-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.