# Pool Heater Sizing Calculator

> Estimate the heater output needed to raise a pool to temperature in a target time, and what a cover saves.

Page: https://craftquantities.com/calculators/pools-water/pool-heater-sizing-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.0, sources checked 2026-10-31, 4 published test vectors.

Heater output required: 23 kW for Pool volume 13210 gal and Temperature rise 14.4 °F, the page's opening figures; on the metric page, 50 m³ and 8 °C give 23 kW. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Pool volume | `volume` | 50 m³ | 13210 gal | l, gal, m3, ft3, yd3; range 0.1–10000000 L |
| Temperature rise | `temperatureRise` | 8 °C | 14.4 °F | c_delta, f_delta; range 1–30 °C |
| Heat-up time (hours) | `heatUpHours` | 24 | 24 | range 1–336 |
| Cover used overnight | `covered` | Yes — cover on when not in use | Yes — cover on when not in use | `yes`, `no` |

- **Pool volume**: Water volume.
- **Temperature rise**: How far the water must be raised.
- **Heat-up time (hours)**: How quickly you want to reach temperature.
- **Cover used overnight**: A cover suppresses evaporation, which is most of the loss.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Heater output required** | 23 kW |
| Energy to raise the water | 465.11 kWh |
| Heat-up power | 19.38 kW |
| Standing loss allowance | 3.33 kW |
| BTU/h | 77,499.85 BTU/h |
| Approximate surface area used | 33.33 m² |

### US customary

| Result | Value |
|---|---|
| **Heater output required** | 23 kW |
| Energy to raise the water | 465.16 kWh |
| Heat-up power | 19.38 kW |
| Standing loss allowance | 3.33 kW |
| BTU/h | 77,508.05 BTU/h |
| Approximate surface area used | 358.83 sq ft |

- Confidence: low.

## How it is worked out

A planning figure. Standing loss depends on wind, humidity, air temperature and shelter, none of which are inputs here — it varies by a factor of two or more between a sheltered and an exposed site.

The working the page shows, in order: Energy to raise the water; Heat-up power; Standing loss allowance; BTU/h; Approximate surface area used; then heater output required.

The method, derived in full:

- [Pool Volume, Turnover and Dosing](https://craftquantities.com/methodology/pool-volume-turnover-and-dosing/): One inferred number — the water volume — sets the chemical dose, the pump flow and the heater, and nobody ever measures it directly.

What this calculation does not cover:

- Surface area is inferred from volume at an assumed 1.5 m (5 ft) average depth. A wide shallow pool loses far more heat than this suggests, and a deep narrow one less.
- Wind is the largest uncontrolled variable in evaporation and is not modelled. An exposed pool can lose twice what a sheltered one does.
- Solar gain is ignored, and on a sunny day it can exceed the heater's output entirely.

## Sources

As the calculator cites them (sources checked 2026-10-31):

- Specific heat capacity of water 4.186 kJ/kg·K; 1 m³ of water = 1000 kg
- Evaporation is the dominant heat loss from an uncovered pool, typically 50-70% of the total — ASHRAE Handbook, Applications: Natatoriums

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does a cover make such a difference?**

Because evaporation carries most of the heat out of an outdoor pool — commonly 50-70% of the total loss. Every kilogram of water that evaporates takes about 2.4 MJ with it — the latent heat at pool temperature, not the 2.26 MJ/kg quoted for boiling water. A cover suppresses that almost entirely, which is why it is the cheapest and most effective thing you can add to a heated pool.

**Should I size for fast heat-up or for holding temperature?**

Mostly for holding, with an acceptable heat-up time. A heater sized to raise the pool eight degrees overnight is enormously oversized for maintaining it, and will cycle. Longer initial heat-up and a heater matched to the standing loss is both cheaper to buy and better to run.

**Why is the confidence low?**

Because standing loss depends on wind speed, humidity, air temperature and how sheltered the pool is, and none of those are inputs here. The energy to raise the water is exact physics; the allowance to hold it is a planning figure that can be out by a factor of two between a sheltered courtyard and an exposed hillside.

## Related calculators

- [Pool Volume Calculator (Rectangular, Round, Oval or Kidney)](https://craftquantities.com/calculators/pools-water/pool-volume-calculator/)
- [Pool Pump Turnover Calculator](https://craftquantities.com/calculators/pools-water/pool-pump-turnover-calculator/)
- [Pool Cover & Liner Area Calculator](https://craftquantities.com/calculators/pools-water/pool-solar-cover-calculator/)
- [In-Ground Concrete Pool Shell Volume Calculator](https://craftquantities.com/calculators/pools-water/pool-shell-volume-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/pool-heater-sizing-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/pool-heater-sizing-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `pool-heater-sizing-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/pool-heater-sizing-calculator.json

---
Source: https://craftquantities.com/calculators/pools-water/pool-heater-sizing-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.