# Well Pressure Tank Sizing Calculator

> Get a recommended pressure tank size based on your pump's flow rate and a minimum pump cycle time.

Page: https://craftquantities.com/calculators/plumbing-hvac/well-pressure-tank-sizing-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.1, sources checked 2026-09-02, 2 published test vectors.

Recommended tank size: 30.3 gal for Pump Flow Rate 10 gal/min, the page's opening figures; on the metric page, 38 L/min gives 115 L. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Pump Flow Rate | `pumpFlow` | 38 L/min | 10 gal/min | lpm, lps, gpm; range 0.1–190 L/min |
| Minimum Pump Run Time (minutes) | `minCycleTimeMin` | 1 | 1 | range 0.5–5 |

- **Pump Flow Rate**: Your well pump's rated flow rate.
- **Minimum Pump Run Time (minutes)**: The shortest the pump should run per cycle to avoid premature wear.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Recommended tank size** | 115 L |
| Required drawdown | 38 L |

### US customary

| Result | Value |
|---|---|
| **Recommended tank size** | 30.3 gal |
| Required drawdown | 10 gal |

- Confidence: medium.

## How it is worked out

Actual drawdown fraction varies by tank precharge pressure and your specific pressure switch cut-in/cut-out settings — check your tank manufacturer's drawdown chart for a precise figure.

The working the page shows, in order: Required drawdown; then recommended tank size.

The method, derived in full:

- [Sealed Circuits: Expansion, Makeup Water and Refrigerant Lines](https://craftquantities.com/methodology/hydronic-and-refrigerant-circuits/): Why an expansion vessel is two to three times bigger than the water it has to absorb, why makeup water is a fault report rather than a consumable, and why a refrigerant line that is too large starves its own compressor of oil.

What this calculation does not cover:

- The 33% usable fraction is a fixed assumption, not something this calculates. Real drawdown depends on the tank's air precharge and on your pressure switch's cut-in/cut-out settings, and the usable fraction shrinks as the switch band moves higher — so a tank set up at a high pressure band delivers less than this assumes. Check the manufacturer's drawdown chart for the model and switch setting you are actually running.
- It treats the pump's rated flow as a constant. A pump's delivered flow changes with the head it is working against and rises and falls across the cut-in to cut-out band, so the flow moving through the tank over a real cycle is not the nameplate figure this uses.
- This sizes a tank against pump cycling and nothing else. It does not look at the well's yield or recovery rate, or at peak simultaneous household demand — a tank large enough to stop short-cycling can still be far too small for a low-yield well or a heavy draw, and that is a storage problem this rule does not address.
- The fixed fraction describes a captive-air tank (bladder or diaphragm). It does not apply to a galvanized air-over-water tank, whose air charge dissolves into the water and needs periodic recharging, nor to a constant-pressure or VFD system, which is deliberately paired with a small tank and is not sized this way.
- This is not an installation specification. It says nothing about the tank's pressure rating against the relief valve setting, the stand or floor loading, freeze protection, the tank tee and pipework, or the well and plumbing code requirements that govern the installation.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Required drawdown = pump flow rate × minimum recommended cycle time (minutes); recommended tank size = required drawdown ÷ typical drawdown fraction (~33% for a standard captive-air tank)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does short-cycling matter?**

A pump that starts and stops too frequently (short-cycling) wears out its motor and pressure switch contacts much faster than one that runs for a reasonable, steady duration each cycle — an undersized pressure tank is a common cause of short-cycling.

**What is 'drawdown' exactly?**

Drawdown is the volume of water a pressure tank can deliver between the pump's cut-in and cut-out pressure settings — it's always less than the tank's total volume, since some volume remains as a compressed air cushion even at cut-out pressure.

**Does a bigger tank always mean better performance?**

A larger tank generally means longer pump run times and less frequent cycling, which is good for pump longevity — but it also costs more and takes up more space, so this estimates a reasonable minimum, not a maximum.

## Related calculators

- [Sump Pump GPM Calculator](https://craftquantities.com/calculators/plumbing-hvac/sump-pump-gpm-calculator/)
- [PSI to Feet of Head Calculator](https://craftquantities.com/calculators/measurements-conversions/psi-to-feet-of-head-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/well-pressure-tank-sizing-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/well-pressure-tank-sizing-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `well-pressure-tank-sizing-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/well-pressure-tank-sizing-calculator.json

---
Source: https://craftquantities.com/calculators/plumbing-hvac/well-pressure-tank-sizing-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.