# Refrigeration Tons, BTU/h and kW Converter

> Convert an air conditioner or heat pump's capacity between refrigeration tons, BTU per hour and kilowatts: a ton is 12,000 BTU/h, which is 3.517 kW.

Page: https://craftquantities.com/calculators/plumbing-hvac/tons-btu-kw-conversion-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-10-05, 5 published test vectors.

Converted capacity: 36,000 BTU/h for Capacity to Convert 3, the page's opening figures. Source: NIST Special Publication 811, Guide for the Use of the International System of Units, Appendix B.8.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Capacity to Convert | `capacity` | 3 | 3 | range 0–10000000 |
| Converting From | `fromUnit` | Refrigeration tons | Refrigeration tons | `tons`, `btuh`, `kw` |
| Show a Tonnage In | `tonsAnswerIn` | BTU per hour (BTU/h) | BTU per hour (BTU/h) | `btuh`, `kw` |

- **Capacity to Convert**: The rated heating or cooling capacity, in the unit chosen below.
- **Converting From**: The unit of the figure above; the result gives the other two, and the watts.
- **Show a Tonnage In**: Which unit the headline gives a tonnage in; the breakdown shows both either way.

`tonsAnswerIn` applies only when `fromUnit` is `tons`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Converted capacity** | 36,000 BTU/h |
| In refrigeration tons | 3 refrigeration tons |
| In BTU per hour (BTU/h) | 36,000 BTU/h |
| In kilowatts (kW) | 10.55 kW |
| In watts (W) | 10,550.56 W |

### US customary

| Result | Value |
|---|---|
| **Converted capacity** | 36,000 BTU/h |
| In refrigeration tons | 3 refrigeration tons |
| In BTU per hour (BTU/h) | 36,000 BTU/h |
| In kilowatts (kW) | 10.55 kW |
| In watts (W) | 10,550.56 W |

## How it is worked out

Converted by definition: one ton of refrigeration is exactly 12,000 BTU/h, and one BTU/h is 0.29307107 W, from the International Table Btu.

The working the page shows, in order: In refrigeration tons; In BTU per hour (BTU/h); In kilowatts (kW); In watts (W); then converted capacity.

The method, derived in full:

- [Unit Conversion, Exactness and Rounding](https://craftquantities.com/methodology/unit-conversion-and-rounding/): Why most conversion factors carry no uncertainty at all, which ones hide a material assumption, and why converting a measurement can never make it more precise than it was.

What this calculation does not cover:

- The arithmetic restates a capacity; it does not measure one. A rating holds at the indoor and outdoor conditions it was tested at, and a heat pump's or air conditioner's real output moves as those change, falling in heating as the outdoor air gets colder.
- These are heat-moving capacities, not electrical loads. A heat pump delivering 3.5 kW (about 12,000 BTU/h) of heat or cooling draws a fraction of that from the supply, so neither the tons nor the kilowatts here size a circuit, a breaker or a generator.
- The ton here is the ton of refrigeration, a rate of heat flow of 12,000 BTU/h, defined from melting a short ton of ice, 2,000 lb (907 kg), in a day. It is not a mass, and it never adds to the tons the same site uses for gravel and stone.
- A size quoted as a round number of tons is a sales label rather than a measurement. Convert the certified capacity on the data sheet, and compare two machines only at the same rating conditions.

## Sources

As the calculator cites them (sources checked 2026-10-05):

- NIST Special Publication 811, Guide for the Use of the International System of Units, Appendix B.8: British thermal unit (International Table) per hour to watt, 2.930 711 E−01; ton of refrigeration (12 000 Btu_IT/h) to watt, 3.516 853 E+03; ton, short (2000 lb), the mass unit, to kilogram 9.071 847 E+02 <https://www.nist.gov/pml/special-publication-811/nist-guide-si-appendix-b-conversion-factors/nist-guide-si-appendix-b8>
- NIST Special Publication 811, footnotes: the Fifth International Conference on the Properties of Steam (London, 1956) defined the International Table calorie as 4.1868 J, so the International Table Btu is exactly 1.055 055 852 62 kJ; the thermochemical Btu rests on the thermochemical calorie of exactly 4.184 J <https://www.nist.gov/pml/special-publication-811/nist-guide-si-footnotes>

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**How many BTU per hour, and how many kilowatts, is one ton?**

Exactly 12,000 BTU/h, which is 3.5169 kW: the ton of refrigeration is defined as 12,000 International Table Btu per hour, and NIST's conversion tables give it as 3,516.853 W. So a 2-ton machine is 24,000 BTU/h or 7.03 kW, and a 3-ton one 36,000 BTU/h or 10.55 kW.

**Where does the ton of cooling get its name?**

From ice. It was the cooling rate of a short ton, 2,000 lb (907 kg), of ice melting over a day, from the years when buildings were cooled with ice, and it was later fixed by definition at 12,000 BTU/h. It is a rate of heat flow, which is why a 3-ton air conditioner weighs nothing like 3 tons.

**How many tons is my heat pump?**

Divide its rated output in kilowatts by 3.517, or in BTU/h by 12,000. An 8 kW heat pump is 2.27 tons, a 5 kW one 1.42 tons, and a 3.5 kW split unit 0.995 of a ton. Use the output, not the electrical input, and the rating for the duty you mean: a heat pump's heating and cooling figures are stated separately.

**Can I size a heat pump or air conditioner from a tonnage?**

Only against a load worked out for the building. Tons, BTU/h and kilowatts are three ways of writing one capacity; the capacity the house needs comes from a heat loss or heat gain calculation, room by room for the emitters and in total for the machine, and a heat pump's output then has to be checked at the design outdoor temperature rather than at its rating point.

## Related calculators

- [BTU/hr to kW Calculator](https://craftquantities.com/calculators/plumbing-hvac/btu-to-kw-calculator/)
- [kW to BTU/hr Calculator](https://craftquantities.com/calculators/plumbing-hvac/kw-to-btu-calculator/)
- [Air Conditioner Size Calculator](https://craftquantities.com/calculators/plumbing-hvac/ac-size-calculator/)
- [Heat Pump Sizing Calculator](https://craftquantities.com/calculators/plumbing-hvac/heat-pump-sizing-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/tons-btu-kw-conversion-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/tons-btu-kw-conversion-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `tons-btu-kw-conversion-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/tons-btu-kw-conversion-calculator.json

---
Source: https://craftquantities.com/calculators/plumbing-hvac/tons-btu-kw-conversion-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.