# Heating & Cooling Load Screening Calculator

> Estimate whole-house heating and cooling loads from envelope areas and U-values — a screening check against a contractor's figure.

Page: https://craftquantities.com/calculators/plumbing-hvac/manual-j-screening-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.0, sources checked 2026-10-31, 4 published test vectors.

Design heat loss: 5,710 W for Total envelope area 3230 sq ft, the page's opening figures; on the metric page, 300 m² gives 5,710 W. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Total envelope area | `envelopeArea` | 300 m² | 3230 sq ft | m2, ft2, mm2, in2; range 0.01–10000 m² |
| Average U-value (W/m²K) | `averageUValue` | 0.6 | 0.6 | range 0.08–5 |
| Internal volume | `volume` | 250 m³ | 8829 ft³ | l, gal, m3, ft3, yd3; range 0.1–20000000 L |
| Air changes per hour | `airChangesPerHour` | 0.7 | 0.7 | range 0.1–10 |
| Design temperature difference | `deltaT` | 24 °C | 43.2 °F | c_delta, f_delta; range 5–60 °C |

- **Total envelope area**: Walls, roof, floor and glazing combined.
- **Average U-value (W/m²K)**: Area-weighted average through the whole envelope.
- **Internal volume**: Floor area times ceiling height.
- **Air changes per hour**: Infiltration and ventilation rate.
- **Design temperature difference**: Internal design temperature minus external design temperature.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Design heat loss** | 5,710 W |
| Fabric loss | 4,320 W |
| Ventilation loss | 1,386 W |
| Kilowatts | 5.71 kW |
| BTU/h | 19,469.68 BTU/h |
| Ventilation as a share of the total | 24.29 % |

### US customary

| Result | Value |
|---|---|
| **Design heat loss** | 5,710 W |
| Fabric loss | 4,321.11 W |
| Ventilation loss | 1,386.05 W |
| Kilowatts | 5.71 kW |
| BTU/h | 19,473.63 BTU/h |
| Ventilation as a share of the total | 24.29 % |

- Confidence: medium.

## How it is worked out

Steady-state whole-house loss. Sound as a screening figure and as a check on a quote; not a substitute for a room-by-room calculation, which is what sizes emitters.

The working the page shows, in order: Fabric loss; Ventilation loss; Kilowatts; BTU/h; Ventilation as a share of the total; then design heat loss.

The method, derived in full:

- [Heating and Cooling Loads, and the Emitters That Meet Them](https://craftquantities.com/methodology/heating-and-cooling-load-estimation/): Why two houses of identical floor area can need three times different capacity, why an oversized air conditioner leaves a room clammy, and why a radiator that suited a boiler is too small for a heat pump.

What this calculation does not cover:

- Whole-house, not room-by-room. It cannot size a radiator or a diffuser, only the plant.
- Steady-state: no solar gain, no internal gains from people and appliances, and no thermal mass. In a well-glazed house solar gain materially reduces the heating requirement and materially increases the cooling one.
- The air-change rate is an assumption unless it came from a blower-door test, and it is often the largest single term.

## Sources

As the calculator cites them (sources checked 2026-10-31):

- Steady-state fabric heat loss: Q = Σ(U × A × ΔT), the basis of every load method including ACCA Manual J and CIBSE Guide A
- Ventilation heat loss: Q = 0.33 × n × V × ΔT (W), CIBSE Guide A — 0.33 Wh/m³K is the volumetric heat capacity of air
- ACCA Manual J (8th ed.) for the full room-by-room procedure this approximates

The site's pages for the documents these name:

- [ACCA Manual J](https://craftquantities.com/standards/acca/acca-manual-j/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is this not called a Manual J calculator?**

Because it is not one, and naming it that would be a misrepresentation. Manual J is a defined room-by-room procedure with specific tables for glazing, orientation, shading, infiltration and duct losses. This is the steady-state equation underneath it applied to the whole house. It will tell you whether a quoted boiler is roughly right; it will not tell you what size radiator the back bedroom needs.

**Why does ventilation matter so much?**

Because heating outdoor air to indoor temperature costs energy, and a draughty house does it continuously. The breakdown shows ventilation as a share of the total — in an old house it is routinely 40-50%, which is why airtightness work often beats adding insulation for the same money.

**Should I size the boiler to this figure?**

Close to it, plus an allowance for domestic hot water and for warm-up after setback. What you should not do is add a large arbitrary margin: an oversized boiler cycles, runs below its condensing temperature, and delivers worse efficiency than the label promises. Modern condensing plant performs best when it is running near its calculated load, not far below it.

**Where do I get a U-value?**

From the assembly. For a UK house whose walls and windows nobody has opened up, RdSAP 10 gives the figures an energy assessor uses in England: single glazing 4.8 W/m²K (0.85 BTU/hr·ft²·°F) in a wood or PVC frame and 5.7 (1.00) in metal; double glazing fitted before 2002 2.7 to 3.1 (0.48 to 0.55) by the width of its gap, 2.0 (0.35) from 2002 and 1.4 (0.25) from 2022; solid brick 2.5 (0.44) up to 200 mm (7.9 in) thick and 1.7 (0.30) from 200 to 280 mm (7.9 to 11 in); a filled cavity 0.7 (0.12) in a wall built before 1976, 0.40 (0.070) from 1976 to 1982 and 0.35 (0.062) from 1983 to 1995; and a wall built since 2007 0.26 to 0.30 (0.046 to 0.053). A US window's NFRC label gives its U-factor in BTU/hr·ft²·°F, and this field takes W/m²K, about 5.68 times that figure. Area-weight them across your envelope — glazing pulls the average up sharply even at modest area.

## Related calculators

- [Air Conditioner Size Calculator](https://craftquantities.com/calculators/plumbing-hvac/ac-size-calculator/)
- [Heat Pump Sizing Calculator](https://craftquantities.com/calculators/plumbing-hvac/heat-pump-sizing-calculator/)
- [Room Heat Loss and Radiator Size Calculator (Watts and BTU)](https://craftquantities.com/calculators/plumbing-hvac/room-heat-loss-calculator/)
- [Boiler Makeup Water Calculator](https://craftquantities.com/calculators/materials-quantities/boiler-makeup-water-calculator/)
- [HVAC Thermal Load (U-Value) Calculator](https://craftquantities.com/calculators/plumbing-hvac/hvac-thermal-load-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/manual-j-screening-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/manual-j-screening-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `manual-j-screening-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/manual-j-screening-calculator.json

---
Source: https://craftquantities.com/calculators/plumbing-hvac/manual-j-screening-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.