# kW to BTU/hr Calculator

> Convert a metric kilowatt heating or cooling output into BTU per hour for specifying US equipment.

Page: https://craftquantities.com/calculators/plumbing-hvac/kw-to-btu-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Equivalent output: 11,942 BTU/hr for Output 3.5, the page's opening figures. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Output (kW) | `kilowatts` | 3.5 | 3.5 | range 0–500 |

- **Output (kW)**: The rated heating or cooling output in kilowatts.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Equivalent output** | 11,942 BTU/hr |
| Conversion factor applied | 3,412.14 BTU/hr per kW |

### US customary

| Result | Value |
|---|---|
| **Equivalent output** | 11,942 BTU/hr |
| Conversion factor applied | 3,412.14 BTU/hr per kW |

## How it is worked out

Converted using an exact defined factor of 3412.141633127968 BTU/hr per kW. Manufacturers round nameplate figures heavily, so a 3.5 kW unit is usually sold as 12,000 BTU/h rather than the exact 11,942.

The working the page shows, in order: Conversion factor applied; then equivalent output.

The method, derived in full:

- [Unit Conversion, Exactness and Rounding](https://craftquantities.com/methodology/unit-conversion-and-rounding/): Why most conversion factors carry no uncertainty at all, which ones hide a material assumption, and why converting a measurement can never make it more precise than it was.

What this calculation does not cover:

- This converts a rating you already have. It is not a heat-loss or heat-gain calculation, so it cannot tell you whether that kilowatt figure is the right capacity for the space — sizing still needs a room-by-room load calculation against your own design conditions.
- The conversion does not know what your kilowatt figure represents. Thermal output, electrical input, and gas input on a net or gross calorific basis all appear as kW on datasheets and are all treated identically here. Compare output against output, or you flatter one machine over another before any arithmetic happens.
- Rating conditions do not travel with the number. A heat pump's kW figure is quoted at particular indoor and outdoor temperatures and falls away as it gets colder outside, and the same machine usually carries different heating and cooling ratings. The BTU/hr you get back describes only the single rating point you typed in.
- The answer is arithmetic, not a catalogue size. Equipment sells in nominal steps with a tolerance band around each, and nothing here snaps the figure to a size a manufacturer actually builds or tells you what the unit you order will test at.
- Nothing here sizes an electrical supply. BTU/hr is heat moved or produced, not power drawn — take circuit, breaker and cable sizing from the nameplate's running current and minimum circuit ampacity, never from a converted capacity.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- 1 BTU/h is defined as 0.29307107017222 W (International Table), so 1 kW = 3412.1416 BTU/h
- Nominal cooling tonnage: 1 ton of refrigeration = 12,000 BTU/h

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does my 3.5 kW unit get sold as 12,000 BTU/hr rather than 11,942?**

Because equipment is marketed in nominal sizes. 12,000 BTU/hr is one ton of refrigeration, a round catalogue size, and manufacturers group nearby outputs under it. Use the nominal figure when ordering and the exact one when doing load calculations — the difference is under half a percent and will not change the plant selection, but it will confuse a paperwork check if you quote a number nobody recognises.

**Should I convert the electrical input or the rated output?**

The rated thermal output. On a heat pump those are very different numbers: a unit drawing 1 kW of electricity can deliver 3–4 kW of heat, because it moves heat rather than making it. Converting the input figure would undersize the equipment by whatever the coefficient of performance is.

**Is a BTU always the same size?**

Not quite. Several BTU definitions exist and differ slightly. HVAC work uses the International Table BTU, which is what this calculator applies, at 0.29307107 W. The thermochemical BTU is about 0.07% smaller — 1054.35 J against the International Table 1055.06 J. The gap is irrelevant for equipment sizing but matters if you are reconciling against a scientific reference.

## Related calculators

- [BTU/hr to kW Calculator](https://craftquantities.com/calculators/plumbing-hvac/btu-to-kw-calculator/)
- [BTU Cooling / AC Sizing Calculator](https://craftquantities.com/calculators/plumbing-hvac/btu-cooling-calculator/)
- [Horsepower to kW Calculator](https://craftquantities.com/calculators/electrical/hp-to-kw-calculator/)
- [Refrigeration Tons, BTU/h and kW Converter](https://craftquantities.com/calculators/plumbing-hvac/tons-btu-kw-conversion-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/kw-to-btu-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/kw-to-btu-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `kw-to-btu-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/kw-to-btu-calculator.json

---
Source: https://craftquantities.com/calculators/plumbing-hvac/kw-to-btu-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.