# Greenhouse Heating BTU Calculator

> Estimate the heater size needed to keep a greenhouse warm, based on glazing type and temperature difference.

Page: https://craftquantities.com/calculators/plumbing-hvac/greenhouse-heating-btu-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.2, sources checked 2026-10-31, 2 published test vectors.

Recommended heater size (BTU/hr): 20,600 BTU/hr for Covering Area 430 sq ft and Temperature Difference 40 °F, the page's opening figures; on the metric page, 40 m² and 22.22 °C give 20,700 BTU/hr. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Covering Area (glazed surface) | `greenhouseArea` | 40 m² | 430 sq ft | m2, ft2, mm2, in2; range 0.01–1000 m² |
| Glazing Type | `glazingType` | Single-layer poly film | Single-layer poly film | `single-poly`, `double-poly`, `glass` |
| Temperature Difference | `tempDiff` | 22.22 °C | 40 °F | c_delta, f_delta; range 3–45 °C |

- **Covering Area (glazed surface)**: The total area of the covering — roof and walls — not the floor.
- **Glazing Type**: Double-layer poly traps an insulating air gap, losing much less heat than single-layer film or glass.
- **Temperature Difference**: The difference between your desired inside temperature and the coldest expected outside temperature.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Recommended heater size (BTU/hr)** | 20,700 BTU/hr |
| Covering area | 40 m² |
| Same output in kW | 6.06 kW |

### US customary

| Result | Value |
|---|---|
| **Recommended heater size (BTU/hr)** | 20,600 BTU/hr |
| Covering area | 430 sq ft |
| Same output in kW | 6.05 kW |

- Confidence: medium.

## How it is worked out

This estimates glazing heat loss only — wind exposure, air leaks around vents and doors, and the greenhouse's surface-area-to-volume ratio (smaller structures lose heat faster per sq ft) can all push real requirements higher.

The working the page shows, in order: Covering area; Same output in kW; then recommended heater size (BTU/hr).

The method, derived in full:

- [Heating and Cooling Loads, and the Emitters That Meet Them](https://craftquantities.com/methodology/heating-and-cooling-load-estimation/): Why two houses of identical floor area can need three times different capacity, why an oversized air conditioner leaves a room clammy, and why a radiator that suited a boiler is too small for a heat pump.

What this calculation does not cover:

- Small houses lose proportionally more than this model suggests, because heat loss scales with surface area while the useful growing volume scales with the cube of the dimension. A propagation frame therefore needs more heat per square metre of glazing than a commercial span, and no surface-to-volume penalty is applied here.
- The covering area is taken as typed and nothing checks it against the structure you actually have. This limitation used to say the covering area 'never enters the calculation', which was true of an earlier floor-area version of this page and is now the opposite of the truth — the glazed surface IS the primary input. What remains is that you have to work that area out yourself, from the sidewalls, the gable ends and the developed length of the roof or arch, and it is always larger than the footprint. Two greenhouses on the same slab, a 1.2 m (4 ft) cold frame and a walk-in with 2.4 m (8 ft) sidewalls, are different numbers here only because you enter different areas.
- Air leakage is excluded. Vent louvres, roll-up sides, door gaps, torn film and an unsealed base skirt admit a separate infiltration load on top of conduction through the covering, and on a loosely sealed or ageing structure that load is a large share of the total.
- Site conditions are excluded: wind speed and exposure, which strip heat from a thin covering far faster than still air; perimeter and ground losses at the foundation; and shelter from buildings, walls or hedging. An exposed field and a sheltered walled garden get the same answer.
- Only three coverings are offered. Thermal or blackout screens drawn at night, a bubble-wrap liner, an insulated north wall, twin-wall polycarbonate, double-wall acrylic, or poly overlaid on old glass cannot be represented by picking one of the listed options, and each of those changes the loss rate materially.
- This is a heat-loss rate, not a heater specification. It carries no allowance for burner efficiency, altitude derate, pull-down after the doors have been open, or the fan and thermostat control needed to hold an even temperature end to end. Any fired heater must still be sized, vented and supplied with combustion air to the manufacturer's data and the applicable fuel-gas code.

## Sources

As the calculator cites them (sources checked 2026-10-31):

- Commonly cited greenhouse heat-loss factors (BTU/hr per sq ft per °F of temperature difference): single-layer poly film ~1.2, double-layer inflated poly ~0.7, glass ~1.1 — air leakage, wind exposure and glazing condition change these materially, and a U-value for the glazing actually installed governs

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does double-layer poly need so much less heat than single-layer?**

The trapped air gap between the two layers acts as an insulating buffer, similar to how double-pane windows outperform single-pane — it roughly cuts heat loss per square foot compared to a single layer of the same material.

**Does this account for the sun's free heat during the day?**

No — this sizes for worst-case heat loss (typically overnight, no sun), which is the standard conservative approach for heater sizing since you need heat exactly when there's no solar gain to help.

**Should I heat the whole greenhouse or just a section?**

For overwintering only sensitive plants, some growers heat just a smaller enclosed section within the greenhouse rather than the whole structure, which can significantly reduce the heater size needed — recalculate using just that section's area if so.

## Related calculators

- [BTU Cooling / AC Sizing Calculator](https://craftquantities.com/calculators/plumbing-hvac/btu-cooling-calculator/)
- [Electric Baseboard Heater Sizing Calculator](https://craftquantities.com/calculators/plumbing-hvac/baseboard-heater-btu-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/greenhouse-heating-btu-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/greenhouse-heating-btu-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `greenhouse-heating-btu-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/greenhouse-heating-btu-calculator.json

---
Source: https://craftquantities.com/calculators/plumbing-hvac/greenhouse-heating-btu-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.