# BTU Cooling / AC Sizing Calculator

> Get a rough estimate of the air conditioner capacity (BTU) needed for a room, adjusted for ceiling height and sun exposure.

Page: https://craftquantities.com/calculators/plumbing-hvac/btu-cooling-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Recommended cooling capacity (BTU/hr): 2,990 BTU/hr for Room Length 13 ft and Room Width 11.5 ft, the page's opening figures; on the metric page, 4 m and 3.5 m give 3,010 BTU/hr. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Room Length | `roomLength` | 4 m | 13 ft | mm, cm, m, in, ft, yd; range 0.01–30 m |
| Room Width | `roomWidth` | 3.5 m | 11.5 ft | mm, cm, m, in, ft, yd; range 0.01–30 m |
| Ceiling Height | `ceilingHeight` | Standard (up to 8 ft / 2.4 m) | Standard (up to 8 ft / 2.4 m) | `standard`, `tall`, `vaulted` |
| Sun Exposure | `sunExposure` | Moderate | Moderate | `low`, `moderate`, `high` |

- **Room Length**: The length of the room to be cooled.
- **Room Width**: The width of the room to be cooled.
- **Ceiling Height**: Taller ceilings mean more air volume to cool.
- **Sun Exposure**: Direct sun through windows adds significant heat load.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Recommended cooling capacity (BTU/hr)** | 3,010 BTU/hr |
| Room area | 14 m² |
| Baseline (20 BTU/sq ft) | 0.88 kW |
| Same capacity in kW | 0.88 kW |

### US customary

| Result | Value |
|---|---|
| **Recommended cooling capacity (BTU/hr)** | 2,990 BTU/hr |
| Room area | 149.5 sq ft |
| Baseline (20 BTU/sq ft) | 2,990 BTU/hr |
| Same capacity in kW | 0.88 kW |

- Confidence: medium.

## How it is worked out

This is a rough planning estimate, not a Manual J load calculation — actual sizing should be verified by an HVAC professional, especially for whole-house systems.

The working the page shows, in order: Room area; Baseline (20 BTU/sq ft); Same capacity in kW; then recommended cooling capacity (BTU/hr).

The method, derived in full:

- [Heating and Cooling Loads, and the Emitters That Meet Them](https://craftquantities.com/methodology/heating-and-cooling-load-estimation/): Why two houses of identical floor area can need three times different capacity, why an oversized air conditioner leaves a room clammy, and why a radiator that suited a boiler is too small for a heat pump.

What this calculation does not cover:

- This is a floor-area rule of thumb, not a load calculation. It reads only room length, width, a three-step ceiling category and a three-step sun category — insulation level, window area and glazing type, air leakage, wall and roof construction, and your local design temperatures are all outside it. It will not satisfy a permit, utility programme or contract that asks for a Manual J (or equivalent) load calculation.
- No internal heat gains are counted. Occupants, cooking, laundry, and electronics or server gear add load this model never sees, so a kitchen, a laundry room or a room that regularly holds several people needs more capacity than the figure shown.
- Ceiling height enters as a fixed multiplier on floor area, not as an actual volume. The real height of a vaulted ceiling, warm-air stratification, and an uninsulated roof or attic directly above the room make no difference to the result.
- The output is sensible cooling capacity only; it does not size for moisture removal. In a humid climate the latent load decides whether a nominally correct unit feels comfortable, and a unit chosen on capacity alone can short-cycle and leave the room cold and clammy.
- It sizes one enclosed room and stops there. Open-plan connections to the rest of the house, multi-room or whole-house distribution, duct and vent sizing, condensate drainage, the electrical supply for the unit, and the capacities actually sold are all outside the calculation.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Rule-of-thumb baseline: approximately 20 BTU per square foot for cooling, within a commonly cited 18-30 BTU/sq ft range depending on insulation, ceiling height, and climate
- A precise sizing should use a full Manual J load calculation performed by an HVAC professional — this tool gives a rough planning estimate only

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**How accurate is this?**

It's a rough planning estimate using a widely-cited rule of thumb, not a substitute for a Manual J load calculation, which accounts for insulation quality, window count and orientation, local climate, and occupancy.

**What does BTU mean here?**

British Thermal Units per hour — a measure of cooling (or heating) capacity. Air conditioner capacity is also often listed in 'tons,' where 1 ton = 12,000 BTU/hr.

**Is bigger always better for an air conditioner?**

No — an oversized AC cools the room quickly but shuts off before properly removing humidity, leaving the room feeling clammy. Right-sizing matters more than maximizing capacity.

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/btu-cooling-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/btu-cooling-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `btu-cooling-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/btu-cooling-calculator.json

---
Source: https://craftquantities.com/calculators/plumbing-hvac/btu-cooling-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.