# Air Conditioner Size Calculator

> Estimate the cooling capacity a space needs in BTU/h and tons, adjusted for climate, insulation, glazing and occupancy.

Page: https://craftquantities.com/calculators/plumbing-hvac/ac-size-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.1.0, sources checked 2026-10-31, 4 published test vectors.

Cooling capacity required (BTU/h): 22,000 BTU/h for Floor area 1080 sq ft, the page's opening figures; on the metric page, 100 m² gives 22,000 BTU/h. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Floor area | `floorArea` | 100 m² | 1080 sq ft | m2, ft2, mm2, in2; range 0.01–2000 m² |
| Climate | `climate` | Moderate — warm summers, 27-32 °C / 80-90 °F | Moderate — warm summers, 27-32 °C / 80-90 °F | `mild`, `moderate`, `hot`, `veryHot` |
| Insulation and airtightness | `insulation` | Average — insulated to code when built | Average — insulated to code when built | `poor`, `average`, `good` |
| Sun exposure | `sunExposure` | Average glazing and exposure | Average glazing and exposure | `shaded`, `average`, `heavy` |
| Regular occupants | `occupants` | 2 | 2 | range 0–100 |
| Includes a kitchen | `kitchen` | No | No | `no`, `yes` |

- **Floor area**: Conditioned floor area of the space.
- **Climate**: Summer design conditions where the building is.
- **Insulation and airtightness**: Overall thermal quality of the envelope.
- **Sun exposure**: How much solar gain the space takes.
- **Regular occupants**: People normally in the space.
- **Includes a kitchen**: Cooking adds a substantial sensible and latent load.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Cooling capacity required (BTU/h)** | 22,000 BTU/h |
| Refrigeration tons | 1.79 tons |
| Kilowatts | 6.31 kW |
| Envelope and solar | 6.31 kW |
| Occupants beyond two | 0 kW |
| Kitchen | 0 kW |

### US customary

| Result | Value |
|---|---|
| **Cooling capacity required (BTU/h)** | 22,000 BTU/h |
| Refrigeration tons | 1.8 tons |
| Kilowatts | 6.33 kW |
| Envelope and solar | 21,600 BTU/h |
| Occupants beyond two | 0 BTU/h |
| Kitchen | 0 BTU/h |

- Confidence: low.

## How it is worked out

A screening estimate, not a design. Equipment should be selected from a room-by-room load calculation (ACCA Manual J in the US, Canada's CSA F280, MCS/CIBSE in the UK, AS/NZS in Australia) before anything is ordered.

The working the page shows, in order: Refrigeration tons; Kilowatts; Envelope and solar; Occupants beyond two; Kitchen; then cooling capacity required (BTU/h).

The method, derived in full:

- [Heating and Cooling Loads, and the Emitters That Meet Them](https://craftquantities.com/methodology/heating-and-cooling-load-estimation/): Why two houses of identical floor area can need three times different capacity, why an oversized air conditioner leaves a room clammy, and why a radiator that suited a boiler is too small for a heat pump.

What this calculation does not cover:

- Does not use window area, orientation, shading coefficient or U-value — a real Manual J does, and glazing is often the largest single term.
- Does not use a measured air-change rate. Infiltration is approximated by the insulation setting alone.
- Does not separate sensible from latent load, so it cannot tell you whether a unit will dehumidify adequately in a humid climate.
- Does not account for duct losses in unconditioned space, which can add 20-30% in a hot loft.

## Sources

As the calculator cites them (sources checked 2026-10-31):

- ACCA Manual J (8th ed.) — residential load calculation. This page is a screening approximation of it, not an implementation.
- 1 ton of refrigeration = 12,000 BTU/h (ASHRAE Terminology)
- ACCA Manual S — equipment selection should follow the calculated load, not floor area alone

The site's pages for the documents these name:

- [ACCA Manual J](https://craftquantities.com/standards/acca/acca-manual-j/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is a bigger air conditioner worse?**

Because cooling and dehumidifying are different jobs. An oversized unit drops the air temperature fast, satisfies the thermostat and stops — before it has run long enough to condense much moisture out. The result is a house that is cold and clammy, with the compressor short-cycling, which wears it out and wastes energy. Correct sizing runs longer at lower capacity, which is what actually removes humidity.

**How does this differ from a real Manual J?**

A Manual J is room by room and uses the actual window areas, orientations and shading; the U-value of every wall, roof and floor assembly; a measured or assumed infiltration rate; duct location and leakage; and separate sensible and latent loads. This uses floor area with four adjustment factors. It is useful for a sanity check on a quote and is not a basis for ordering equipment.

**What is a ton of cooling?**

12,000 BTU/h — historically the rate of cooling from melting a ton of ice in a day. It is a capacity, not a weight. Residential systems are commonly 1.5 to 5 tons, and equipment is sold in half-ton steps, so the calculated figure gets rounded to the nearest available size.

**Should I round up to the next size?**

Usually down, or to the nearest. Manual S allows selecting up to about 15% above the calculated cooling load; beyond that the short-cycling and humidity problems start. Rounding up 'to be safe' is the exact instinct that causes most oversizing.

## Related calculators

- [BTU Cooling / AC Sizing Calculator](https://craftquantities.com/calculators/plumbing-hvac/btu-cooling-calculator/)
- [Heating & Cooling Load Screening Calculator](https://craftquantities.com/calculators/plumbing-hvac/manual-j-screening-calculator/)
- [Mini-Split/VRF Line Set Length Derating Calculator](https://craftquantities.com/calculators/materials-quantities/mini-split-line-length-derating-calculator/)
- [Duct Size Calculator](https://craftquantities.com/calculators/plumbing-hvac/duct-size-calculator/)
- [Refrigeration Tons, BTU/h and kW Converter](https://craftquantities.com/calculators/plumbing-hvac/tons-btu-kw-conversion-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/ac-size-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/ac-size-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `ac-size-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/ac-size-calculator.json

---
Source: https://craftquantities.com/calculators/plumbing-hvac/ac-size-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.