# Winder Stair Calculator (Kite, Balanced and Dancing Winders, Quarter and Half Turns: Each Set Out)

> Set out kite or balanced (dancing) winders from your width and newel: each winder's shape, its going at your code's walk line and full-size blanks.

Page: https://craftquantities.com/calculators/materials-quantities/winder-stair-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-11-13, 8 published test vectors.

Going of each winder on the walk line: 14.5 in for Winders in each quarter turn 2, the page's opening figures; on the metric page, 2 gives 364 mm. Source: UK.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Turn | `turn` | Quarter turn (90°, an L) | Quarter turn (90°, an L) | `quarter`, `half` |
| Winders in each quarter turn | `perQuarter` | 2 | 2 | range 2–6 |
| Layout at the newel | `layout` | Fanned from the newel's centre (kite) | Fanned from the newel's centre (kite) | `radial`, `newel`, `balanced`, `well` |
| Open well diameter | `wellDiameter` | 400 mm | 16 in | mm, cm, m, in, ft, yd; range 0–2 m |
| Curved string depth | `stringDepth` | 275 mm | 10.75 in | mm, cm, m, in, ft, yd; range 0.1–0.5 m |
| Curved string thickness | `stringThickness` | 42 mm | 1.75 in | mm, cm, m, in, ft, yd; range 0.012–0.1 m |
| Ply thickness, if laminated | `plyThickness` | 6 mm | 0.25 in | mm, cm, m, in, ft, yd; range 0.002–0.02 m |
| Tread thickness | `treadThickness` | 32 mm | 1.25 in | mm, cm, m, in, ft, yd; range 0.015–0.08 m |
| Balanced treads in all | `balancedTreads` | 7 | 7 | range 3–15 |
| Stair width (newel centre line to the wall) | `stairWidth` | 0.9 m | 3 ft | mm, cm, m, in, ft, yd; range 0.5–2 m |
| Newel post (square) | `newel` | 100 mm | 4 in | mm, cm, m, in, ft, yd; range 0–0.3 m |
| Setting-out walk line from the newel's face | `walkOffset` | 0 mm | 0 in | mm, cm, m, in, ft, yd; range 0–1.5 m |
| Riser height | `riserHeight` | 185 mm | 7.25 in | mm, cm, m, in, ft, yd; range 0.1–0.25 m |
| Going of the straight treads | `going` | 260 mm | 10.25 in | mm, cm, m, in, ft, yd; range 0.15–0.4 m |
| Nosing projection | `nosing` | 25 mm | 1 in | mm, cm, m, in, ft, yd; range 0–0.05 m |
| Code for the readout | `buildingCode` | US — IRC | US — IRC | `irc`, `uk`, `au`, `ca`, `generic` |

- **Turn**: How far the winders turn the stair.
- **Winders in each quarter turn**: Three is the common kite turn; two gives deeper winders.
- **Layout at the newel**: Where each nosing line meets the newel.
- **Open well diameter**: The circle the inner string curves round.
- **Curved string depth**: The wreathed string's depth, square to its pitch.
- **Curved string thickness**: The finished string's thickness.
- **Ply thickness, if laminated**: One lamination, bent round a former.
- **Tread thickness**: For the housings in the curved string.
- **Balanced treads in all**: Tapered treads over the turn and into both flights.
- **Stair width (newel centre line to the wall)**: The flight's width from the newel's centre line to the wall.
- **Newel post (square)**: The post at the inside corner; 0 for a wall corner.
- **Setting-out walk line from the newel's face**: 0 sets it in the middle of the clear width.
- **Riser height**: The stair's riser, each winder one up.
- **Going of the straight treads**: For the comparison with the winders.
- **Nosing projection**: Added to each blank's front edge if the treads overhang.
- **Code for the readout**: The code the winders are read against, each at its own measuring point.

`wellDiameter` applies only when `layout` is `well`.
`stringDepth` applies only when `layout` is `well`.
`stringThickness` applies only when `layout` is `well`.
`plyThickness` applies only when `layout` is `well`.
`treadThickness` applies only when `layout` is `well`.
`balancedTreads` applies only when `layout` is `balanced`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Going of each winder on the walk line** | 364 mm |
| Winders | 2 winders |
| Least going at the code's measuring point | 271.55 mm |
| Narrowest end at the newel | 50 mm |
| Widest blank's wide end | 900 mm |
| Largest blank, board length | 1,237.44 mm |
| Largest blank, board depth | 900 mm |
| Area of all the blanks | 0.81 m² |
| Rise through the turn | 370 mm |

### US customary

| Result | Value |
|---|---|
| **Going of each winder on the walk line** | 14.5 in |
| Winders | 2 winders |
| Least going at the code's measuring point | 10.72 in |
| Narrowest end at the newel | 2 in |
| Widest blank's wide end | 36 in |
| Largest blank, board length | 49.5 in |
| Largest blank, board depth | 36 in |
| Area of all the blanks | 8.97 sq ft |
| Rise through the turn | 14.5 in |

## How it is worked out

WITHIN THE LIMITS CHECKED — 2 winders, 272 mm (10.69 in) each deep at the walk line, 12 in (305 mm) from the narrow side, narrow ends from 50 mm (1.97 in), inside the figures this page reads for IRC R311.7.5.2.1. Limits checked, not an approval. At the newel the narrowest end is 50 mm (1.97 in): the part of each winder under 6 in (152 mm) deep must be the newel's or outside the clear width (R311.7.5.2.1).

The working the page shows, in order: Winders; Least going at the code's measuring point; Narrowest end at the newel; Widest blank's wide end; Largest blank, board length; Largest blank, board depth; Area of all the blanks; Rise through the turn; then going of each winder on the walk line.

The method, derived in full:

- [Stair Geometry, Ramps and Guarding](https://craftquantities.com/methodology/stair-geometry-and-guarding/): Why you choose the number of risers rather than their height, why the spread across a whole flight is held to three-eighths of an inch, and why a cable railing has to be checked deflected rather than at rest.

What this calculation does not cover:

- This sets winders out; it does not approve a turn. Each code measures winders at its own point and some limit how many may replace a landing: the readout compares, your building official decides.
- The newel, the bearers or carriages under the winders and their housings are the joiner's or your engineer's to size; the newel's size here only places the narrow ends.
- The winders fill a square turn (two for a half turn) the stair's width on a side, round a square newel or a circular open well; balanced (dancing) winders are set out for a quarter turn only, and a well that is not circular is not set out here.
- Round an open well the nosings are radial from the well's centre and the inner string is a wreath bent or cut to the well: its unrolled template, plies and plank are geometry; whether a string of that depth and thickness carries the stair, and its joints to the straight strings, are the stair maker's or your engineer's.
- Distances "from the narrow side" are read as radii from the newel's centre, half the newel plus the code's distance; on a square newel the true distance differs a little near the corner.
- Blanks are the walking surfaces nosing to nosing; the nosing projection, the housing into the walls and the newel, and the bearers under each winder are the joiner's.

A professional must decide:

- This sets winders out; it does not approve a turn. Each code measures winders at its own point and some limit how many may replace a landing: the readout compares, your building official decides.
- The newel, the bearers or carriages under the winders and their housings are the joiner's or your engineer's to size; the newel's size here only places the narrow ends.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-11-13):

- US: IRC R311.7.5.2.1 — winder treads at least 10 in deep at the walk line, 12 in from the narrow side, and at least 6 in at any point within the clear width
- UK: Approved Document K (2013 edition), paragraphs 1.25–1.27 and Diagram 1.9 — the going of tapered treads measured at the middle of a stair under 1 m wide (270 mm in from each side of a wider one), 50 mm least at the narrow end, consecutive tapered treads the same going, and not less than the straight treads' going; Table 1.1 for a private stair's going (220–300 mm) <https://assets.publishing.service.gov.uk/media/60d5bdcde90e07716f516cfd/Approved_Document_K.pdf>
- Australia: NCC 2022 Housing Provisions 11.2.2(3) — up to 3 consecutive winders in place of a quarter landing and up to 6 in place of a half, their going constant; Table 11.2.2a going 240–355 mm <https://ncc.abcb.gov.au/editions/ncc-2022/adopted/housing-provisions/11-safe-movement-and-access/part-112-stairway-and-ramp-construction>
- Canada: National Building Code 9.8.4.6 — winders turning 30° or 45°, a set turning no more than 90°, read as this site's L- and U-shaped stair page reads them
- Each nosing line through a point on the setting-out walk line at equal angles of the turn; the going at a radius is the distance between two lines' crossings of that circle

The site's pages for the documents these name:

- [International Residential Code](https://craftquantities.com/standards/icc/irc/)
- [Approved Documents to the Building Regulations (England)](https://craftquantities.com/standards/uk-gov/uk-approved-documents/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why do three winders off a corner post fail the IRC on a 36 in stair?**

Each turns 30°, so 12 in from the narrow side the going is about 2 x 13.75 x sin 15° = 7.1 in, under the 10 in R311.7.5.2.1 asks for at the walk line. Two winders of 45° give about 10.5 in there.

**What is a kite winder?**

In a quarter turn of three winders fanned from the newel, the middle one reaches the outer corner and is kite-shaped; the two either side are near-triangles.

**Can I print the winders full size?**

Yes: every blank numbered, with its nosing edge and walk line, or the whole turn on plan as a setting-out board, tiled over A4 or Letter with a calibration square on each sheet.

## Related calculators

- [L-Shaped and U-Shaped Stair Calculator (Landings, Winders, Stringers, Treads and Risers)](https://craftquantities.com/calculators/materials-quantities/landing-stair-calculator/)
- [Stair Rise & Run Calculator](https://craftquantities.com/calculators/renovation-construction/stair-calculator/)
- [Spiral Staircase Calculator (Spiral, Helical and Curved Stairs: Treads, Going, Headroom and Handrail)](https://craftquantities.com/calculators/materials-quantities/spiral-staircase-calculator/)
- [Stair Stringer Calculator (Cuts, Floor Opening, Treads and Risers)](https://craftquantities.com/calculators/materials-quantities/stair-stringer-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/winder-stair-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/winder-stair-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `winder-stair-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/winder-stair-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/winder-stair-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.