# Wheelchair Turning Space Clearance Checker

> Check whether a floor space meets the ADA minimum diameter for a circular wheelchair turning space.

Page: https://craftquantities.com/calculators/materials-quantities/wheelchair-turning-space-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Limiting available dimension: 5 ft for Available Space Width 5 ft and Available Space Depth 5 ft, the page's opening figures; on the metric page, 1.6 m and 1.6 m give 1.6 m. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Available Space Width | `spaceWidth` | 1.6 m | 5 ft | mm, cm, m, in, ft, yd; range 0.01–3 m |
| Available Space Depth | `spaceDepth` | 1.6 m | 5 ft | mm, cm, m, in, ft, yd; range 0.01–3 m |

- **Available Space Width**: The available clear width of the floor space.
- **Available Space Depth**: The available clear depth of the floor space.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Limiting available dimension** | 1.6 m |
| Required minimum diameter (ADA 304.3.1) | 1.52 m |

### US customary

| Result | Value |
|---|---|
| **Limiting available dimension** | 5 ft |
| Required minimum diameter (ADA 304.3.1) | 5 ft |

## How it is worked out

MEETS the 60 in (1,524 mm) circular turning space minimum. This checks only the 60-inch (1.524m) circular turning space requirement of ADA Section 304.3.1 — it does not check the alternative T-shaped turning space option (Section 304.3.2), floor slope (max 1:48), surface requirements, or obstructions/protrusions into the space.

The working the page shows, in order: Required minimum diameter (ADA 304.3.1); then limiting available dimension.

The method, derived in full:

- [Clearances, Layout and Accessibility Dimensions](https://craftquantities.com/methodology/clearances-layout-and-accessibility/): Why an accessible dimension is a measured anthropometric result rather than a round number, why a parking layout is set by the vehicle that turns worst, and why a door needs floor space on the side nobody draws.

What this calculation does not cover:

- Two dimensions can only describe a rectangle. A bathroom that wraps around a vanity, or a landing that narrows past a radiator, has no single clear width and depth — enter the overall room and this reports a pass while no 60 in circle actually fits anywhere in the clear area. What has to fit is one continuous unobstructed circle in one location, and on an irregular plan that gets drawn, not measured twice.
- The turning circle is one geometry in the room and it has to coexist with others. Maneuvering clearance on the pull side of the door and clear floor space at each fixture are separately dimensioned areas with their own rules, and a room can hold a compliant circle while the door approach or a fixture approach has nowhere to go. They are permitted to overlap one another, which is what makes this a layout exercise rather than a sum of areas.
- 60 inches is this document's minimum, not a design target and not the only figure in play. Larger powered chairs and mobility scooters need more room to come about than the minimum circle allows, and a space held to a different standard — a dwelling unit, or a jurisdiction working from ICC A117.1 rather than the 2010 ADA Standards — is measured against that document's own dimensions instead of this one.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Per the ADA 2010 Standards Section 304.3.1, a circular turning space requires a minimum diameter of 60 inches (1,525 mm / 1.524m) — verified against a regulatory-text mirror this session (up.codes), which confirmed the 60-inch/1525mm circular turning space figure directly.

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is the minimum diameter for a wheelchair turning space?**

Per ADA 2010 Standards Section 304.3.1, a circular turning space requires a minimum diameter of 60 inches (1,525 mm / 1.524m).

**Why does this checker use the smaller of width and depth?**

A circular turning space needs the full required diameter in every direction, so the limiting (smaller) available dimension determines whether a circle of the required size actually fits.

**Does a passing result mean the space is fully ADA-compliant?**

No — this checks only the 304.3.1 circular turning space diameter. It does not check the alternative T-shaped turning space option (Section 304.3.2), floor slope (max 1:48), surface requirements, or obstructions/protrusions into the space.

## Related calculators

- [Commercial ADA Accessible Ramp Length & Landing Calculator](https://craftquantities.com/calculators/materials-quantities/ada-ramp-length-calculator/)
- [Commercial Revolving Door Vestibule Footprint Calculator](https://craftquantities.com/calculators/materials-quantities/revolving-door-footprint-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/wheelchair-turning-space-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/wheelchair-turning-space-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `wheelchair-turning-space-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/wheelchair-turning-space-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/wheelchair-turning-space-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.