# Welded Wire Mesh Calculator — Reinforcing Mesh Sheets for a Slab

> How many sheets of welded wire mesh (steel fabric) a slab takes at your sheet size and the lap on your drawing, and how many of them need cutting.

Page: https://craftquantities.com/calculators/materials-quantities/welded-wire-mesh-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-10-05, 5 published test vectors.

Mesh sheets to order: 4 sheets for Slab Length 30 ft, Slab Width 19.5 ft and Gap Between the Slab Edge and the Mesh 0 in, the page's opening figures; on the metric page, 9 m, 6 m and 0 mm give 4 sheets. Source: Wire Reinforcement Institute, Manual of Standard Practice.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Slab Length | `slabLength` | 9 m | 30 ft | mm, cm, m, in, ft, yd; range 0.1–200 m |
| Slab Width | `slabWidth` | 6 m | 19.5 ft | mm, cm, m, in, ft, yd; range 0.1–200 m |
| Gap Between the Slab Edge and the Mesh | `edgeCover` | 0 mm | 0 in | mm, cm, m, in, ft, yd; range 0–0.5 m |
| Sheet As Sold | `sheetSize` | 2438 mm x 6.1 m, WRI's 96 in x 20 ft (US west coast, Canada) | 96 in x 20 ft, WRI (US west coast, Canada) | `wri-96x240`, `wri-96x150`, `uk-4800x2400`, `custom` |
| Sheet Length, Tip to Tip | `sheetLength` | 6.1 m | 20 ft | mm, cm, m, in, ft, yd; range 1–20 m |
| Sheet Width, Between the Outside Wires | `sheetWidth` | 2.438 m | 8 ft | mm, cm, m, in, ft, yd; range 0.6–5 m |
| Lap Between Sheets, Wire to Wire | `lap` | 202 mm | 8 in | mm, cm, m, in, ft, yd; range 0–0.5 m |
| End Overhangs of One Sheet, Both Together | `endOverhangs` | 152 mm | 6 in | mm, cm, m, in, ft, yd; range 0–0.4 m |

- **Slab Length**: The long side of the slab, edge to edge.
- **Slab Width**: The short side of the slab, edge to edge.
- **Gap Between the Slab Edge and the Mesh**: How far short of each edge the mesh stops, from your drawing. Opens at nothing, so the sheets reach the edges.
- **Sheet As Sold**: The sheet your merchant sells; a UK reader's page opens on the 4.8 by 2.4 m (15.7 by 7.9 ft) standard sheet.
- **Sheet Length, Tip to Tip**: The long side of one sheet as delivered, from the tip of one wire end to the tip of the other.
- **Sheet Width, Between the Outside Wires**: The short side of one sheet, measured between its two outside wires, not across the wire ends.
- **Lap Between Sheets, Wire to Wire**: From your drawing, between the outermost wires of the two sheets: 8 in (202 mm) opens, one 6 in (152 mm) space plus 2 in (50 mm).
- **End Overhangs of One Sheet, Both Together**: The wire ends past the last cross wire at both ends of a sheet, added together: 6 in (152 mm) opens, one wire space on 6 x 6 mesh.

`sheetLength` applies only when `sheetSize` is `custom`.
`sheetWidth` applies only when `sheetSize` is `custom`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Mesh sheets to order** | 4 sheets |
| Sheets with their length along the slab | 6 sheets |
| Sheets with their length across the slab | 4 sheets |
| Sheets in each run, in the layout used | 4 sheets |
| Runs side by side, in the layout used | 1 run |
| Sheets that need cutting, in the layout used | 4 sheets |
| Overlap where sheets meet end to end, tip to tip | 354 mm |
| Slab area the mesh covers | 54 m² |
| Area of the sheets bought | 59.46 m² |

### US customary

| Result | Value |
|---|---|
| **Mesh sheets to order** | 4 sheets |
| Sheets with their length along the slab | 6 sheets |
| Sheets with their length across the slab | 4 sheets |
| Sheets in each run, in the layout used | 4 sheets |
| Runs side by side, in the layout used | 1 run |
| Sheets that need cutting, in the layout used | 4 sheets |
| Overlap where sheets meet end to end, tip to tip | 14 in |
| Slab area the mesh covers | 585 sq ft |
| Area of the sheets bought | 640 sq ft |

## How it is worked out

The headline lays the sheets with their length across the slab, the way that takes fewer sheets; the other way is the row below it. Side by side each sheet advances its width less the lap; end to end, its length less the lap and both end overhangs, which lie inside the overlap. The last sheet of a run is cut where the run does not land exactly.

The working the page shows, in order: Sheets with their length along the slab; Sheets with their length across the slab; Sheets in each run, in the layout used; Runs side by side, in the layout used; Sheets that need cutting, in the layout used; Overlap where sheets meet end to end, tip to tip; Slab area the mesh covers; Area of the sheets bought; then mesh sheets to order.

The method, derived in full:

- [Rolls, Sheets and the Lap Between Them](https://craftquantities.com/methodology/rolls-sheets-and-laps/): Why covering an area with rolls is a strip count rather than a division, why the lap is bought twice over, and why turning the strips the other way can change the order.

What this calculation does not cover:

- This is a sheet count, not a reinforcement design. Which mesh a slab takes, whether it needs mesh at all, where in the depth it sits and the cover to it are the slab's design, and a slab carrying vehicles, racking or a structure above is designed by an engineer; the page never chooses a mesh.
- The lap and the overhangs are the drawing's. For plain wire under ACI 318 the Wire Reinforcement Institute gives one wire space plus 2 in (50 mm), not less than 6 in (150 mm), between the outermost wires of the two sheets, with the overhangs added, and notes that for slabs on the ground the splice only has to hold the sheets together; ACI 439.5R-18, as the American Society of Concrete Contractors reports it, gives one square plus 2 in (50 mm). The page opens on those figures for 6 x 6 mesh. Laps for UK fabric to BS 4483, which is made from ribbed bars, come from the drawing or the engineer's schedule; this page has no figure for them.
- Sheets are laid as the Wire Reinforcement Institute measures them: the width between the outside wires, the length tip to tip with the end overhangs in it. Side overhangs, no more than 1 in (25 mm) a side on a WRI sheet that names none, are left out of the cover, which can only raise the count. The UK sheet is laid at the 4.8 by 2.4 m (15.7 by 7.9 ft) it is sold as; the listings read do not say whether that includes its overhangs, so a drawing that gives the lap as an overall overlap of the sheets is entered as the lap, with the end overhangs at nothing.
- One layer over one rectangle. A second layer, extra mesh at re-entrant corners or around openings, strips at thickened edges, and an L-shaped or irregular slab are not counted; work an irregular slab as rectangles and add them.
- The cut sheets are counted, not nested: an offcut long enough to start the next run is used again on site, and this count does not assume it. Rolls, where a mesh comes in them, are flattened and cut to length before they are placed, which the Wire Reinforcement Institute recommends.
- Chairs, spacers and tie wire are separate items; the chair page counts them.

A professional must decide:

- This is a sheet count, not a reinforcement design. Which mesh a slab takes, whether it needs mesh at all, where in the depth it sits and the cover to it are the slab's design, and a slab carrying vehicles, racking or a structure above is designed by an engineer; the page never chooses a mesh.
- Electrics: circuit design, protection, cable sizing and the work itself are for a qualified or licensed electrician, under the rules where you build.

## Sources

As the calculator cites them (sources checked 2026-10-05):

- Wire Reinforcement Institute, Manual of Standard Practice — Structural Welded Wire Reinforcement (WWR-500, 7th edition, © July 2006): style designation (6 x 12-W12 x W5 means wires at 6 in and 12 in, W12 and W5 being 0.12 and 0.05 sq in); width the centre-to-centre distance between the outside longitudinal wires, not including overhangs; side overhangs no greater than 1 in (25 mm) a side where none is specified; length tip to tip, always including the end overhangs; preferably the sum of the two end overhangs should equal the transverse wire spacing; common sheet sizes 96 in x 12.5 ft (US except west coast), 96 x 16, 96 x 20, 84 x 20 and 84 x 25 ft (US west coast), and 48 in x 8 ft and 96 in x 12, 14, 16 and 20 ft in Canada (2438 mm x 3.7, 4.3, 4.9 and 6.1 m); styles may be obtained in roll form, flattened and cut to size before placement; plain wire splices not less than one space + 2 in (50 mm) nor 6 in (150 mm), overhangs added to the splice length; for slabs on ground the minimum splice is 2 in plus overhangs <https://images.thdstatic.com/catalog/pdfImages/36/369e9e37-c56d-41b3-868d-a71698c88cbc.pdf>
- American Society of Concrete Contractors, "WWR Lap Splice Requirements": ACI 439.5R-18, Guide for Specification, Manufacture and Construction Use of Welded Wire Reinforcement, section 6.4, gives a lap splice of one square plus 2 inches for plain wire WWR; non-structural slabs-on-ground are designed to ACI 360 and the design professional sets the splice <https://ascconline.org/Home/News/articleType/ArticleView/articleId/51/WWR-Lap-Splice-Requirements>
- BSI, BS 4483:2025 Steel fabric for the reinforcement of concrete. Specification (current; published 27 March 2025; supersedes BS 4483:2005, which is withdrawn), the standard UK fabric is made to: sheets of machine-welded fabric made from ribbed bars <https://knowledge.bsigroup.com/products/steel-fabric-for-the-reinforcement-of-concrete-specification-1>
- Capital Reinforcing (Ireland) Ltd, reinforcing mesh product page: mesh produced to BS 4483; A type square mesh A393, A252, A193 and A142, in standard sheets or flying end sheets <https://www.specifiedby.com/capital-reinforcing-ireland-ltd/reinforcing-mesh-1>
- Heaton Manufacturing, Steel Reinforcing Mesh Sizes (size chart, reviewed 3 April 2026): steel reinforcing mesh sizes in the UK are defined by BS 4483 and commonly supplied in standard 4.8 m x 2.4 m sheets, area 11.52 m²; A393, A252, A193 and A142 at a 200 mm pitch both ways <https://heatonmanufacturing.co.uk/reinforcing-mesh-sizes/>
- Jewson, BRC Standard Fabric Reinforcement 4.8 x 2.4m x 6mm (L x W x Dia): the maker's part WWS A142, product length 4.8 m, product width 2.4 m <https://www.jewson.co.uk/p/brc-standard-fabric-reinforcement-4-8-x-2-4m-x-6mm-l-x-w-x-dia-grey-FNREST07>

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**How many sheets of mesh does a slab take?**

One sheet for the first sheet length along each run and one more for each further sheet length less the overlap, in both directions, multiplied together. A 9 by 6 m (29.5 by 19.7 ft) slab, or the imperial page's 30 by 19.5 ft (9.1 by 5.9 m), which comes out the same, in WRI's 96 in by 20 ft (2438 mm by 6.1 m) sheets, lapped 8 in (202 mm) with 6 in (152 mm) of end overhangs: laid with their length along the slab, two sheets along and three runs across make six; turned the other way, four sheets in one run cover it, because the slab's width fits inside one sheet's length. A UK reader's page opens on the 4.8 by 2.4 m (15.7 by 7.9 ft) standard sheet, and the same slab takes six. The page works both ways round and leads with the smaller.

**What lap should the sheets have?**

The one on the slab's drawing or specification. For plain wire mesh the Wire Reinforcement Institute gives the least under ACI 318 as one wire space plus 2 in (50 mm), and not less than 6 in (150 mm), measured between the outermost wires of the two sheets; ACI 439.5R-18 gives the same, one square plus 2 in (50 mm), so a 6 in (152 mm) mesh laps 8 in (202 mm) wire to wire. Where sheets meet end to end the overhanging wire ends lie in the overlap too, and WRI says they should preferably add up to one cross-wire space, so the sheets overlap 14 in (356 mm) tip to tip, the 8 in (202 mm) lap and 6 in (152 mm) of overhangs. WRI also notes that a slab on the ground rarely uses the mesh's full strength, so its splice only has to hold the sheets together, and the American Society of Concrete Contractors reports a project where the designer accepted a one-square lap. Laps for UK fabric to BS 4483 come from the drawing or the engineer's schedule. Who decides is the slab's designer.

**Which mesh does my slab need?**

That is the slab's design, and the page does not choose it. In the US and Canada mesh is named by its style: 6 x 6-W1.4 x W1.4 is wires at 6 in (152 mm) each way, each W1.4, a wire of 0.014 sq in (9 mm²); in the UK, fabric made to BS 4483 is named A142, A193 and so on. The sheet size you buy is what this page needs, and it counts the same for any of them.

**Why does turning the sheets round change the count?**

Because a run that is a little longer than a whole number of sheets wastes most of a sheet at its end, and the two directions waste differently. On a 9 by 6 m (29.5 by 19.7 ft) slab in 20 ft (6.1 m) sheets, sheets laid lengthwise need a second sheet along the 9 m (29.5 ft) run and a third run across the 6 m (19.7 ft) width; turned through a right angle, the 6 m (19.7 ft) fits under one sheet's 6.1 m (20 ft) and the 9 m (29.5 ft) takes four widths. Six sheets against four for the same slab.

**Does the count include offcuts I can reuse?**

No. The cut sheets are counted as cut, and an offcut long enough to start another run is a saving on site that the count does not assume. On a slab with many runs the saving can be real; on a small one the offcuts are usually too short to place.

## Related calculators

- [Rebar Calculator](https://craftquantities.com/calculators/materials-quantities/rebar-calculator/)
- [Rebar Chair and Bolster Count Calculator](https://craftquantities.com/calculators/materials-quantities/rebar-chair-count-calculator/)
- [Concrete Calculator](https://craftquantities.com/calculators/materials-quantities/concrete-calculator/)
- [Concrete Slab + Rebar Combined Mass Calculator](https://craftquantities.com/calculators/materials-quantities/slab-rebar-combined-mass-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/welded-wire-mesh-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/welded-wire-mesh-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `welded-wire-mesh-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/welded-wire-mesh-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/welded-wire-mesh-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.