# Perimeter Weeping Tile Pipe Segment Calculator

> Calculate how many standard-length pipe segments are needed for a foundation perimeter weeping tile (footing drain) run.

Page: https://craftquantities.com/calculators/materials-quantities/weeping-tile-segment-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Pipe segments needed: 15 segments for Foundation Perimeter 150 ft and Standard pipe segment length 10 ft, the page's opening figures; on the metric page, 45 m and 3.05 m give 15 segments. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Foundation Perimeter | `foundationPerimeter` | 45 m | 150 ft | mm, cm, m, in, ft, yd; range 0.01–300 m |
| Standard pipe segment length | `pipeSegmentLength` | 3.05 m | 10 ft | mm, cm, m, in, ft, yd; range 0.01–120 m |

- **Foundation Perimeter**: The total perimeter length of the foundation to be drained.
- **Standard pipe segment length**: The stock length of one pipe segment as sold.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Pipe segments needed** | 15 segments |

### US customary

| Result | Value |
|---|---|
| **Pipe segments needed** | 15 segments |

## How it is worked out

The method, derived in full:

- [Perimeter Runs, Stock Lengths and Mitres](https://craftquantities.com/methodology/perimeter-runs-and-mitres/): Why a room's area tells you nothing about how much skirting it needs, why adding a door can increase the trim order, and why a crown moulding mitre is neither forty-five degrees nor half the corner angle.

What this calculation does not cover:

- The perimeter asked for is a single number, and the pipe circuit is not the wall line. Weeping tile is laid outside the footing at the level of its underside, so on a rectangular plan the circuit is longer than the wall perimeter by roughly eight times the offset from the wall face. A 250 mm offset adds about 2 m to a 45 m foundation, which is the difference between 15 segments and 16.
- One rounding is applied to the whole circuit, which assumes the pipe runs as a single unbroken line. Rigid pipe is cut at every corner and at the tee to the sump, and each cut leaves an off-cut usually too short to start the next side. A 45 m perimeter taken as four 11.25 m sides needs four 3.05 m segments per side, so sixteen rather than the fifteen the single division returns.
- Nothing here is hydraulic. Pipe diameter is not an input, so the count is identical for a 75 mm and a 150 mm pipe, and no fall is asked for, so a run laid dead level returns the same number as one laid to grade. The length also stops at the circuit itself: a site with no gravity outlet needs a sump and pump, which this does not size.
- The segment length field is written for stock stick lengths and accepts nothing above 6 m (about 19.7 ft), so the 30.5 m (100 ft) coils of flexible perforated pipe commonly used on residential footing drains cannot be entered here, even though the field's help mentions coiled lengths. A coil is bought by the roll, and for a coiled product the quantity is the run length divided by the roll length, worked out separately.
- The pipe is one line item of a footing drain and the parts that make it work do not scale with the segment count. The washed stone envelope around the pipe is a volume, the filter fabric or pipe sock is an area, and cleanout risers are counted per fitting. Where the design calls for both an exterior footing drain and an interior line under the slab, this number covers one of them.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Segment count = ceil(foundation perimeter ÷ standard pipe segment length), the standard method for estimating pipe segments along a continuous perimeter drain run

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why round up to a whole number of segments?**

Pipe segments are sold in fixed stock lengths, so any partial length remaining still requires cutting from a full segment — rounding up ensures enough material is purchased to complete the run.

**Does this include fittings like corners, tees, or a sump connection?**

No — this calculates the base linear pipe quantity only. Corner elbows, tee connections, and the fittings needed to route the drain to a sump pit or daylight outlet should be counted separately based on your layout.

**Should I add extra for overlap at joints?**

This calculator assumes segments are butted or coupled end-to-end with negligible overlap. If your connection method requires overlap or a coupling that consumes pipe length, add a small allowance to the foundation perimeter before calculating.

## Related calculators

- [French Drain Gravel Calculator](https://craftquantities.com/calculators/auto-utility/french-drain-calculator/)
- [Foundation Sheet Drain Drainage Rate Calculator](https://craftquantities.com/calculators/materials-quantities/sheet-drain-rate-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/weeping-tile-segment-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/weeping-tile-segment-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `weeping-tile-segment-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/weeping-tile-segment-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/weeping-tile-segment-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.