# Wall Formwork and Shuttering Calculator (Form Area, Ties, Wales and Studs for a Poured Wall)

> The form a poured concrete wall takes on both faces: contact area with stop-ends and box-outs, the tie grid, wales, studs and form sheets.

Page: https://craftquantities.com/calculators/materials-quantities/wall-formwork-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-10-10, 2 published test vectors.

Form contact area: 533 sq ft for Wall Length 33 ft, Wall Height 8 ft and Wall Thickness 7.75 in, the page's opening figures; on the metric page, 10 m, 2.4 m and 200 mm give 48.5 m². Source: Masons Supply Company (MASCO), Concrete Forming and Accessories catalogue, p. 40, Jahn Forming System.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Wall Length | `wallLength` | 10 m | 33 ft | mm, cm, m, in, ft, yd; range 0.3–200 m |
| Wall Height | `wallHeight` | 2.4 m | 8 ft | mm, cm, m, in, ft, yd; range 0.2–6 m |
| Wall Thickness | `wallThickness` | 200 mm | 7.75 in | mm, cm, m, in, ft, yd; range 0.05–1 m |
| Free Ends Closed by a Stop-End | `stopEnds` | 2 | 2 | range 0–20 |
| Openings Through the Wall | `openings` | 1 | 1 | range 0–30 |
| Opening Width | `openingWidth` | 900 mm | 35 in | mm, cm, m, in, ft, yd; range 0–6 m |
| Opening Height | `openingHeight` | 600 mm | 24 in | mm, cm, m, in, ft, yd; range 0–4 m |
| Tie Spacing Along the Wall | `tieSpacingHorizontal` | 600 mm | 24 in | mm, cm, m, in, ft, yd; range 0.1–3 m |
| Tie Spacing Up the Wall | `tieSpacingVertical` | 300 mm | 12 in | mm, cm, m, in, ft, yd; range 0.1–3 m |
| Wale Spacing Up the Wall | `waleSpacing` | 750 mm | 30 in | mm, cm, m, in, ft, yd; range 0.2–3 m |
| Wales in Each Row | `walePlies` | A single wale | A single wale | `1`, `2` |
| Stud Spacing Along the Wall | `studSpacing` | 400 mm | 16 in | mm, cm, m, in, ft, yd; range 0–1.2 m |

- **Wall Length**: The run of wall poured in one form, end to end.
- **Wall Height**: From the top of the footing to the top of the pour.
- **Wall Thickness**: The concrete's thickness, from the drawing.
- **Free Ends Closed by a Stop-End**: How many ends of the pour need a bulkhead across them: two for a straight wall, none for a closed ring.
- **Openings Through the Wall**: Window or door openings boxed out of the pour.
- **Opening Width**: Each opening's width as poured.
- **Opening Height**: Each opening's height as poured.
- **Tie Spacing Along the Wall**: How far apart the ties stand along the wall, from your form maker.
- **Tie Spacing Up the Wall**: How far apart the rows of ties are up the wall, from your form maker.
- **Wale Spacing Up the Wall**: How far apart the horizontal wales run up each face.
- **Wales in Each Row**: One member in each row, or a pair the tie passes between.
- **Stud Spacing Along the Wall**: The vertical studs behind the sheathing on each face; zero for a panel system that has its own.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Form contact area** | 48.5 m² |
| Both faces, openings taken off | 46.92 m² |
| Stop-ends across the free ends | 0.96 m² |
| Box-outs round the openings | 0.6 m² |
| Form ties | 136 ties |
| Tie positions along the wall | 17 positions |
| Tie rows up the wall | 8 rows |
| Wale rows on each face | 4 rows |
| Wales, lineal, both faces | 80 m |
| Studs, both faces | 52 studs |
| Studs, lineal | 124.8 m |
| Form sheets for both faces | 17 sheets |

### US customary

| Result | Value |
|---|---|
| **Form contact area** | 533 sq ft |
| Both faces, openings taken off | 516.33 sq ft |
| Stop-ends across the free ends | 10.33 sq ft |
| Box-outs round the openings | 6.35 sq ft |
| Form ties | 136 ties |
| Tie positions along the wall | 17 positions |
| Tie rows up the wall | 8 rows |
| Wale rows on each face | 4 rows |
| Wales, lineal, both faces | 264 ft |
| Studs, both faces | 52 studs |
| Studs, lineal | 416 ft |
| Form sheets for both faces | 17 sheets |

## How it is worked out

Both faces the full height, 2 stop-ends and 1 box-out; 136 ties on the grid you gave, 17 along by 8 up.

The working the page shows, in order: Both faces, openings taken off; Stop-ends across the free ends; Box-outs round the openings; Form ties; Tie positions along the wall; Tie rows up the wall; Wale rows on each face; Wales, lineal, both faces; Studs, both faces; Studs, lineal; Form sheets for both faces; then form contact area.

The method, derived in full:

- [Spacing, Pitch and the Count That Follows](https://craftquantities.com/methodology/spacing-pitch-and-count/): Why a run divided by a spacing gives the number of gaps and not the number of things, why the division rounds up rather than to nearest, and what the leftover bay at the end does to both.

What this calculation does not cover:

- A count of form, not a formwork design. Whether the sheathing, studs, wales and ties hold the wet concrete depends on the rate of pour, the mix, the temperature and each part's rating; the form maker's tables or a formwork designer decide the spacings you enter, and the pressure and tie spacing pages check them.
- Ties are a full grid over the face, the first a half spacing in from each end and from the top and bottom. Ties are not taken out where an opening interrupts the grid, and a panel system's tie holes fall where its panels put them, so read the count off the maker's layout where the two differ.
- One straight run of one height. Corners, pilasters, steps in the footing and a wall that changes height are separate runs; at a corner the outside form runs past the inside one by the wall's thickness, which is not added here.
- With a manufactured panel system the studs and wales are part of the panels. Set the stud spacing to zero and use the contact area and the tie count; the panel count is the maker's layout.
- Bracing, kickers, stakes, form oil, chamfer strips, the brackets or wedges that lock each tie, and a walkway at the top of the form are not counted.
- Sheets are bought for both faces gross, as if each were cut from whole sheets with the openings sawn out; a reused form, or sheets ripped to a wall lower than a sheet, changes that.

## Sources

As the calculator cites them (sources checked 2026-10-10):

- Masons Supply Company (MASCO), Concrete Forming and Accessories catalogue, p. 40, Jahn Forming System: the most common snap tie spacings are 12 in vertical x 24 in horizontal, 16 in x 24 in and 12 in x 12 in, the ties 12 in in from the sides of a 4 ft panel and 6 in from the top and bottom of an 8 ft one; based on 3/4 in Plyform Class I and 2x4 S4S studs, normal-weight concrete, slump no more than 4 in <https://masco.net/ARCHIVE/pdf/catalogs/formingandaccessories/snaptiesystem_pg40.pdf>
- QUIKRETE, Project: Concrete Walls: a straight wall form of 1/2, 5/8 or 3/4 in exterior plywood sheathing, studs, spacers, ties and wales; frames of 2x4s with studs on 16 in centres; wales in forms more than 4 or 5 ft high, spaced no more than 30 in on centre; the form run slightly longer than the wall so a stop board closes its end <https://www.quikrete.com/PDFs/Projects/ConcreteWalls.pdf>
- Doka, Framax Xlife framed formwork brochure: panel heights of 1.35, 2.70 and 3.30 m, form ties up to 1.35 m apart, and only two form-tie layers for pouring heights up to 3.15 m with the 3.30 m panel <https://www.doka.com/web/media/files/doka_framedformwork_framaxxlife_en.pdf>

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**How much formwork does a concrete wall need?**

Both faces of the wall, the full height, plus a stop-end across each free end and a box-out round each opening. A 10 m wall 2.4 m high (33 by 8 ft) is 48 m² (517 sq ft) of faces before anything is taken off; one opening 900 by 600 mm (35 by 24 in) takes 1.08 m² (11.6 sq ft) off the two faces and adds 0.6 m² (6.5 sq ft) of box-out in a wall 200 mm (8 in) thick. The total touching the concrete is the contact area, the figure formwork is planned and ordered by.

**How many form ties will I need?**

One at every point of the grid your form maker gives, starting half a spacing in from each end, the top and the bottom. On the MASCO catalogue's common Jahn layout of 24 in along by 12 in up, an 8 ft high wall has eight rows and a tie every 2 ft along it: 128 ties on a 32 ft run. A framed panel system ties far wider apart, so its own layout governs.

**Does the page decide the tie spacing?**

No. The spacing that holds the wet concrete depends on its pressure, which grows with the rate of pour and falls with temperature and setting time, and on the sheathing, studs and tie rating. Work the pressure out on the formwork pressure page, check the tie grid on the tie spacing page, and take the maker's table over either; this page only counts the grid.

**What are wales and studs?**

Studs stand upright behind the sheathing and stop it bowing between ties; wales run along the wall across the studs, keeping the face straight and carrying the studs to the ties. On a site-built plywood form both are timber you buy by length, which is why the page gives them in lineal metres or feet. A manufactured panel has them built in.

## Related calculators

- [Concrete Calculator](https://craftquantities.com/calculators/materials-quantities/concrete-calculator/)
- [Concrete Formwork Tie Spacing Calculator](https://craftquantities.com/calculators/materials-quantities/formwork-tie-spacing-calculator/)
- [ACI 347 Wall Formwork Rate-of-Placement Pressure Calculator](https://craftquantities.com/calculators/materials-quantities/wall-formwork-pressure-calculator/)
- [Concrete Formwork Calculator](https://craftquantities.com/calculators/materials-quantities/concrete-formwork-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/wall-formwork-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/wall-formwork-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `wall-formwork-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/wall-formwork-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/wall-formwork-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.