# Roof Truss Raised-Heel Height Calculator

> Calculate the raised heel height needed on a roof truss to fit full-depth insulation at the eave.

Page: https://craftquantities.com/calculators/materials-quantities/truss-heel-height-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Recommended raised-heel height: 15.5 in for Desired Insulation Depth at Eave 12 in and Bottom Chord Depth 3.5 in, the page's opening figures; on the metric page, 304.8 mm and 88.9 mm give 394 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Desired Insulation Depth at Eave | `insulationDepth` | 304.8 mm | 12 in | mm, cm, m, in, ft, yd; range 0.01–0.6096 m |
| Bottom Chord Depth | `bottomChordDepth` | 88.9 mm | 3.5 in | mm, cm, m, in, ft, yd; range 0.01–0.18415 m |

- **Desired Insulation Depth at Eave**: The full loose-fill or batt insulation depth you want maintained all the way out to the exterior wall line.
- **Bottom Chord Depth**: The depth (height) of the truss's bottom chord member.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Recommended raised-heel height** | 394 mm |

### US customary

| Result | Value |
|---|---|
| **Recommended raised-heel height** | 15.5 in |

- Confidence: medium.

## How it is worked out

A simplified stack-up estimate — confirm the exact raised-heel height with your truss manufacturer's engineering, which also accounts for ventilation baffle clearance.

The method, derived in full:

- [Snow, Uplift and the Roof's Load Path](https://craftquantities.com/methodology/roof-loads-and-the-load-path/): Why a warm sheltered roof carries more snow than an exposed cold one, why building next to an existing low roof can overload it without touching it, and why a collar tie and a rafter tie are not the same member.

What this calculation does not cover:

- Every inch of heel raises the whole roof. The ridge, the gable end, the fascia and the top of the siding all go up by the amount calculated here, so on a site with a height limit, an eave line to match, or an existing roof to tie into, the heel is constrained from above before insulation depth gets a say.
- The field asks for a DEPTH, and what an energy code sets is an R-value. Depth only becomes R through the material's R per unit of thickness, so switching from loose-fill fiberglass to dense-packed cellulose to rigid foam changes the heel needed for the same R considerably. Settle the insulation material first, then come back to this.
- Past a certain height the heel stops being packing and becomes structure. That tall vertical at the bearing has to carry roof diaphragm shear down into the top plate, which means it gets blocked or sheathed to a detail on the truss engineering drawing. The stack-up here gives the dimension and stops there.

A professional must decide:

- Past a certain height the heel stops being packing and becomes structure. That tall vertical at the bearing has to carry roof diaphragm shear down into the top plate, which means it gets blocked or sheathed to a detail on the truss engineering drawing.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Energy-heel (raised-heel) truss design: heel height = desired insulation depth at the eave + bottom chord depth, so full R-value insulation is maintained out to the wall line

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why raise the heel at all, if the truss already spans?**

To get the insulation over the wall plate without crushing it. At a standard heel the top and bottom chords converge to almost nothing where they meet the wall, so the insulation has to be squeezed into a wedge exactly where the roof meets the cold outside wall — and compressed insulation loses most of its value, producing a cold strip around the whole perimeter of the ceiling and the condensation and mould that follow it. A raised or energy heel keeps full depth right out to the wall plate, and it does something else useful at the same time: it lifts the underside of the roof away from the eaves so ventilation can still pass over the insulation rather than being blocked by it. It is a thermal and ventilation dimension that happens to be set in the truss shop.

**Why does a standard (non-raised-heel) truss compress insulation at the eave?**

Because on a standard truss the bottom chord meets the top chord right at the wall plate, leaving very little vertical space at the eave. Insulation gets compressed or thinned out right where the roof meets the wall, which is exactly where you want full depth to avoid a cold spot.

**How does a raised heel fix this?**

By adding vertical framing at the heel joint, which lifts the top chord above the bottom chord by an extra amount. In a raised-heel (energy-heel) truss this stack-up adds the desired full insulation depth on top of the bottom chord's own depth, keeping the insulation from being squeezed out near the wall.

**Does this include ventilation baffle clearance above the insulation?**

No — this is a simplified insulation-plus-bottom-chord stack-up only. Your truss manufacturer's engineering should add clearance for a ventilation baffle/chute above the insulation to maintain soffit-to-ridge airflow.

## Related calculators

- [Rafter Bird's Mouth Cut Calculator](https://craftquantities.com/calculators/materials-quantities/birds-mouth-cut-calculator/)
- [King Post Truss Member Length Calculator](https://craftquantities.com/calculators/materials-quantities/king-post-truss-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/truss-heel-height-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/truss-heel-height-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `truss-heel-height-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/truss-heel-height-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/truss-heel-height-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.