# Wood Truss Camber Calculator

> Estimate the recommended manufactured upward camber for a wood truss from its calculated dead-load deflection.

Page: https://craftquantities.com/calculators/materials-quantities/truss-camber-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Recommended camber: 0.585 in for Calculated Dead-Load Deflection 0.39 in, the page's opening figures; on the metric page, 10 mm gives 15 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Calculated Dead-Load Deflection | `deadLoadDeflection` | 10 mm | 0.39 in | mm, cm, m, in, ft, yd; range 0.001–0.06 m |

- **Calculated Dead-Load Deflection**: The truss's calculated deflection under dead load alone.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Recommended camber** | 15 mm |

### US customary

| Result | Value |
|---|---|
| **Recommended camber** | 0.585 in |

- Confidence: medium.

## How it is worked out

1.5× is a commonly-used manufacturer rule of thumb — confirm your truss supplier's actual camber schedule for the specific span and load.

The method, derived in full:

- [Deflection, Creep and Vibration: What Governs a Span](https://craftquantities.com/methodology/deflection-and-vibration/): Why doubling a span multiplies its deflection by sixteen, why a stronger grade of steel does nothing for it, and why a floor that passes every deflection check can still be unacceptable to walk on.

What this calculation does not cover:

- Camber changes the truss's SHAPE, not its stiffness. A truss cambered 15 mm (0.59 in) still deflects exactly as far under load as the same truss built flat — the sag simply starts from a hump instead of from level. If a truss is failing a span/deflection limit, camber does nothing for it; deeper chords, closer spacing or a shorter span do.
- It is a shop dimension and there is no site version of it. Camber is pressed in during fabrication, so it has to be on the truss order — a truss delivered flat cannot be cambered afterwards, and jacking one on the wall to fake it loads the connector plates in a direction they were never designed for.
- Nothing here covers what sits under the cambered bottom chord. As the camber goes out under dead load the chord travels down onto anything below it, so non-bearing partitions need a slip connection at the top rather than nails into the chord — fixed tight, that partition starts carrying roof load it was never framed for and the ceiling cracks in a line along it.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Truss manufacturers commonly build in upward camber equal to approximately 1.5× the calculated dead-load deflection, to offset long-term sag and present a level/slightly-arched ceiling under dead load

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why build camber into a truss at all?**

Wood trusses sag over time under sustained dead load (long-term creep); building in an initial upward camber offsets this expected sag so the truss appears level, or only very slightly arched, once dead load is fully applied.

**Why 1.5x the dead-load deflection specifically?**

This is a commonly-used manufacturer rule of thumb that accounts for both the calculated elastic dead-load deflection and additional long-term creep deflection in wood, not just the instantaneous deflection alone.

**Should camber be based on live load too?**

No — camber is sized to offset the sustained dead load (and its long-term creep), since live loads are transient and camber is a permanent, built-in geometry set at fabrication.

## Related calculators

- [Truss Bottom Chord Deflection Calculator](https://craftquantities.com/calculators/materials-quantities/truss-bottom-chord-deflection-calculator/)
- [Glulam Beam Deflection Checker](https://craftquantities.com/calculators/materials-quantities/glulam-beam-deflection-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/truss-camber-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/truss-camber-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `truss-camber-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/truss-camber-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/truss-camber-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.