# Truss Bottom Chord Deflection Calculator

> Check a truss bottom chord's calculated deflection (acting as a ceiling joist) against the standard L/240 ceiling limit.

Page: https://craftquantities.com/calculators/materials-quantities/truss-bottom-chord-deflection-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 3 published test vectors.

Bottom chord deflection: 0.231 in for Ceiling Uniform Load 500 and Moment of Inertia I 8.71, the page's opening figures, to compare with the limit shown with it; a comparison, not a check. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Ceiling Uniform Load (N/m) | `udl` | 500 | 500 | range 50–5000 |
| Span | `span` | 3 m | 10 ft | mm, cm, m, in, ft, yd; range 0.01–15 m |
| Modulus of Elasticity E | `elasticModulus` | 11000 MPa | 1595420 psi | pa, kpa, mpa, psi, psf, in_wc; range 5000000000–20000000000 Pa |
| Moment of Inertia I (×10⁶ mm⁴) | `momentOfInertia` | 8.71 | 8.71 | range 0.5–100 |

- **Ceiling Uniform Load (N/m)**: The uniformly distributed ceiling load carried by the bottom chord.
- **Span**: The bottom chord's span between panel points — where the webs pick it up — not the truss's overall clear span.
- **Modulus of Elasticity E**: The bottom chord lumber's modulus of elasticity.
- **Moment of Inertia I (×10⁶ mm⁴)**: The bottom chord's cross-sectional moment of inertia.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Bottom chord deflection** | 5.5 mm |
| L/240 ceiling limit | 12.5 mm |

### US customary

| Result | Value |
|---|---|
| **Bottom chord deflection** | 0.231 in |
| L/240 ceiling limit | 0.5 in |

- Confidence: medium.
- The figure is compared against a limit; that is a check of the number, not an approval.

## How it is worked out

The deflection this bottom chord works out to is below the L/240 ceiling deflection limit for this span shown with it — The L/240 convention the building codes use for a ceiling gives it. Being under one limit is not a design. Nothing else is checked here — not the other limit states, not the connections, not the member the load arrives from.

The working the page shows, in order: L/240 ceiling limit; then bottom chord deflection.

The method, derived in full:

- [Deflection, Creep and Vibration: What Governs a Span](https://craftquantities.com/methodology/deflection-and-vibration/): Why doubling a span multiplies its deflection by sixteen, why a stronger grade of steel does nothing for it, and why a floor that passes every deflection check can still be unacceptable to walk on.

What this calculation does not cover:

- The bottom chord is modelled as a simply supported beam spanning the full width of the truss, which is not how a truss carries its load. Web members tie the chord to the top chords at panel points and the chord runs continuously past them, so the local bending is over a panel length rather than the whole span, and the L⁴ term alone puts a 6 m (20 ft) span at 81 times a 2 m (6.5 ft) panel before any credit for that continuity. The overall deflection of the truss, which comes from every member stretching and shortening and is what the ceiling below actually follows, is not calculated anywhere on this page.
- The load field is a line load along one chord, not a ceiling pressure, and it can only be uniform. A 0.5 kN/m² ceiling on trusses at 600 mm (24 in) centres works out at 300 N/m of chord, and the page does no tributary-width conversion, so a figure quoted per square metre has to be converted before it is typed in. A water tank or a stack of stored boxes cannot be entered as what it is either, and the same total weight concentrated at mid-span deflects a simple span 1.6 times as much as it does spread evenly.
- Nothing here is a strength check. A bottom chord carries the truss's tension force at the same time as this bending, and what usually governs its size is the combined tension-and-bending interaction rather than a deflection ratio. Chords are spliced with toothed metal plates where the timber runs out, and the plate at a splice or at the heel joint is often the limiting component of the whole truss.
- This is the instantaneous elastic deflection, and almost all of a bottom chord's load is permanent, since plasterboard, insulation and self-weight sit there for the life of the roof. The value that eventually opens a ceiling joint is the crept one, which Eurocode 5 obtains by multiplying the permanent share by (1 + kdef) — around 1.8 for solid timber in a roof space treated as service class 2 — while other codes apply their own multiplier, so the factor is jurisdictional.
- Downward deflection is not the only way a bottom chord moves a ceiling. In a cold loft the chord sits buried in insulation while the timber above it dries and moves, and the differential arches the chord upward in winter, opening a gap along the top of internal partitions. That is a seasonal moisture effect with no term in this formula, and the remedy is slip fixings at the partition head rather than a stiffer chord.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- Uniformly-loaded simple beam deflection D = 5wL^4/(384EI), applied to the truss bottom chord acting as a ceiling joist, checked against the standard L/240 ceiling deflection limit

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What actually fails first when a bottom chord deflects?**

The ceiling, long before the timber. A bottom chord has plenty of strength in reserve at the deflection that cracks a plasterboard joint, so the limit that governs is a serviceability one written to protect the finish rather than the structure — which is why it is expressed as a fraction of the span rather than as a stress. It is also why the load case that matters is often the one nobody drew: boarding a loft for storage, or a water tank sat on the chords, applies a load the truss was never designed for and does it in the middle of the span where deflection is worst. A crack running the length of a ceiling below a newly boarded loft is the usual way this arrives.

**Why check the bottom chord against L/240 rather than L/360?**

L/240 is the standard code deflection limit for ceilings (non-plaster), which is what a truss bottom chord typically supports — L/360 is the tighter limit generally reserved for floors or plaster ceilings.

**What loads should be included in the uniform load input?**

Include the ceiling dead load (drywall, insulation, and the chord's own weight) plus any applicable attic storage live load, expressed as a load per linear meter of chord.

**Does passing this check mean the truss is fully engineered?**

No — this checks bottom chord deflection alone. The overall truss (top chord, webs, plates, and bearing) must be designed and verified by the truss manufacturer's engineering per ANSI/TPI 1.

## Related calculators

- [Glulam Beam Deflection Checker](https://craftquantities.com/calculators/materials-quantities/glulam-beam-deflection-calculator/)
- [Wood Truss Camber Calculator](https://craftquantities.com/calculators/materials-quantities/truss-camber-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/truss-bottom-chord-deflection-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/truss-bottom-chord-deflection-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `truss-bottom-chord-deflection-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/truss-bottom-chord-deflection-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/truss-bottom-chord-deflection-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.