# Tree Root Protection Area Calculator (BS 5837 RPA and AS 4970 Notional Root Zone)

> The root protection area BS 5837 sets from a tree's stem diameter, or AS 4970's root zones, for one stem or several, and how far works sit from its edge.

Page: https://craftquantities.com/calculators/materials-quantities/tree-root-protection-area-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-09-22, 8 published test vectors.

Radius of the protected area: 24 ft for Stem Diameter 24 in and Distance from the Stem to the Nearest Works 30 ft, the page's opening figures; on the metric page, 620 mm and 9.1 m give 7.44 m. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Standard | `standard` | BS 5837:2012 — root protection area (UK) | BS 5837:2012 — root protection area (UK) | `bs5837`, `as4970` |
| Number of Stems | `stems` | One stem | One stem | `one`, `two-to-five`, `more-than-five` |
| Stem Diameter | `stem1` | 620 mm | 24 in | mm, cm, m, in, ft, yd; range 0.05–3 m |
| Stem 2 Diameter (0 if none) | `stem2` | 300 mm | 11.75 in | mm, cm, m, in, ft, yd; range 0–3 m |
| Stem 3 Diameter (0 if none) | `stem3` | 250 mm | 9.75 in | mm, cm, m, in, ft, yd; range 0–3 m |
| Stem 4 Diameter (0 if none) | `stem4` | 0 mm | 0 in | mm, cm, m, in, ft, yd; range 0–3 m |
| Stem 5 Diameter (0 if none) | `stem5` | 0 mm | 0 in | mm, cm, m, in, ft, yd; range 0–3 m |
| Mean Stem Diameter | `meanDiameter` | 150 mm | 6 in | mm, cm, m, in, ft, yd; range 0.02–1.5 m |
| Number of Stems (count) | `stemCount` | 8 | 8 | range 6–40 |
| Trunk Diameter Above the Root Buttress (0 to skip) | `buttressDiameter` | 700 mm | 28 in | mm, cm, m, in, ft, yd; range 0–4 m |
| Distance from the Stem to the Nearest Works (0 to skip) | `distanceToWorks` | 9.1 m | 30 ft | mm, cm, m, in, ft, yd; range 0–60 m |

- **Standard**: The British standard's root protection area, or the Australian standard's notional root zone.
- **Number of Stems**: Trees that fork below the measuring height are treated as several stems combined into one diameter.
- **Stem Diameter**: The stem's diameter at 1.5 m (4 ft 11 in) above ground for BS 5837, or 1.4 m (4 ft 7 in) for AS 4970; the first stem of a forked tree.
- **Stem 2 Diameter (0 if none)**: The diameter of stem 2, measured at the same height as the first; leave at 0 if the tree has fewer stems.
- **Stem 3 Diameter (0 if none)**: The diameter of stem 3, measured at the same height as the first; leave at 0 if the tree has fewer stems.
- **Stem 4 Diameter (0 if none)**: The diameter of stem 4, measured at the same height as the first; leave at 0 if the tree has fewer stems.
- **Stem 5 Diameter (0 if none)**: The diameter of stem 5, measured at the same height as the first; leave at 0 if the tree has fewer stems.
- **Mean Stem Diameter**: The average diameter of the stems of a many-stemmed tree or coppice stool.
- **Number of Stems (count)**: How many stems the tree has at the measuring height.
- **Trunk Diameter Above the Root Buttress (0 to skip)**: For AS 4970's structural root zone: the trunk diameter just above the flare at the base.
- **Distance from the Stem to the Nearest Works (0 to skip)**: From the centre of the stem to the nearest edge of the excavation, trench or structure.

`stem2` applies only when `stems` is `two-to-five`.
`stem3` applies only when `stems` is `two-to-five`.
`stem4` applies only when `stems` is `two-to-five`.
`stem5` applies only when `stems` is `two-to-five`.
`meanDiameter` applies only when `stems` is `more-than-five`.
`stemCount` applies only when `stems` is `more-than-five`.
`buttressDiameter` applies only when `standard` is `as4970`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Radius of the protected area** | 7.44 m |
| Stem diameter | 620 mm |
| Root protection area | 173.9 m² |
| Distance from the stem to the works | 9.1 m |
| Works beyond the edge (negative: inside it) | 1.66 m |

### US customary

| Result | Value |
|---|---|
| **Radius of the protected area** | 24 ft |
| Stem diameter | 24 in |
| Root protection area | 1,809.56 sq ft |
| Distance from the stem to the works | 30 ft |
| Works beyond the edge (negative: inside it) | 6 ft |

## How it is worked out

Twelve times the stem diameter as the radius of a circle. BS 5837 lets the arboriculturist change the circle's shape to follow the roots actually present, keeping the area the same, so the circle is the starting geometry rather than the only one. The nearest works sit outside the protected circle.

The working the page shows, in order: Stem diameter; Root protection area; Distance from the stem to the works; Works beyond the edge (negative: inside it); then radius of the protected area.

The method, derived in full:

- [Clearances, Layout and Accessibility Dimensions](https://craftquantities.com/methodology/clearances-layout-and-accessibility/): Why an accessible dimension is a measured anthropometric result rather than a round number, why a parking layout is set by the vehicle that turns worst, and why a door needs floor space on the side nobody draws.

What this calculation does not cover:

- It sets out the standard's geometry from the diameter you measured. It does not assess the tree's condition, its species' tolerance of root loss, or whether a Tree Preservation Order, a conservation area or a planning condition applies — those sit with the arboricultural report and the planning authority.
- A circle about the stem. Roots follow the ground, not the geometry: a kerb, a building, a watercourse or a change in level can confine them to one side, and the arboriculturist may reshape the protected area to match, keeping its area.
- A tree's roots also affect the ground well beyond the protected area. On shrinkable clay the foundations near it are a separate question, set by the soil's volume change potential, the species' water demand and its mature height — see the modified plasticity index calculator.

## Sources

As the calculator cites them (sources checked 2026-09-22):

- BS 5837:2012 Trees in relation to design, demolition and construction, 4.6.1 and Annexes C and D: the root protection area is a circle whose radius is twelve times the stem diameter measured at 1.5 m above ground, capped at 707 m²; for two to five stems the combined diameter is √(d1² + d2² + …), and for more than five the mean stem diameter × √(number of stems)
- AS 4970:2025 Protection of trees on development sites (the second edition, which superseded AS 4970-2009): notional root zone radius = 12 × the diameter at standard height, 1.4 m, no less than 2 m and no more than 15 m, stems combined as √(Σd²); structural root zone radius = (D × 50)^0.42 × 0.64 from the diameter D just above the root buttress, no less than 1.5 m

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is the radius twelve times the stem diameter?**

It is the standards' proxy for how far the roots a tree cannot afford to lose extend, taken from the one dimension that can be measured quickly and repeatably. A 620 mm (24.4 in) stem gives a radius of 7.44 m (24.4 ft) and an area of about 174 m² (1,873 sq ft) — the same figure in both units, because twelve times a diameter in inches is a radius in feet — a far larger patch of ground than the crown suggests on a young tree, and often a smaller one on an old, spreading one.

**How do I measure a tree with several stems?**

Measure each stem at the standard height — 1.5 m (4 ft 11 in) for BS 5837, 1.4 m (4 ft 7 in) for AS 4970 — and combine them. Up to five stems combine as the square root of the sum of their squares; above five, BS 5837 uses the mean diameter times the square root of the number. Three stems of 200, 300 and 250 mm (7.9, 11.8 and 9.8 in) combine to 438.7 mm (17.3 in), a radius of 5.26 m (17.3 ft).

**What happens above 707 m²?**

BS 5837 caps the area there, which is a circle of 15 m (49 ft) radius — reached by any stem over about 1.25 m (49 in). AS 4970 caps the radius at 15 m directly and also sets a 2 m (6 ft 7 in) minimum, so a small tree still gets a protected zone worth fencing.

**Can the protected area be a different shape from a circle?**

Yes, under both standards, where the arboriculturist finds the roots constrained or displaced — by a building, a road, a change in level — and the area stays the same. The circle is what the arithmetic gives before anyone has looked at the ground; the report fixes the final shape, and the fencing follows the report.

## Related calculators

- [Modified Plasticity Index Calculator (NHBC 4.2 Volume Change Potential)](https://craftquantities.com/calculators/materials-quantities/modified-plasticity-index-calculator/)
- [Radius to Area Calculator](https://craftquantities.com/calculators/measurements-conversions/radius-to-area-calculator/)
- [Land Clearing & Grubbing Debris Volume Calculator](https://craftquantities.com/calculators/materials-quantities/land-clearing-debris-volume-calculator/)
- [Temporary Construction Fence Panel Count Calculator](https://craftquantities.com/calculators/materials-quantities/temp-fence-panel-count-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/tree-root-protection-area-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/tree-root-protection-area-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `tree-root-protection-area-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/tree-root-protection-area-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/tree-root-protection-area-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.