# Timber Shear Connector Count Calculator

> How many split-ring or shear-plate connector units a joint needs: its design load divided by one unit's rated capacity from the NDS tables or maker's data.

Page: https://craftquantities.com/calculators/materials-quantities/timber-shear-connector-count-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Connector units needed: 7 connector units for Total Joint Load 11.24 kip and Per-Connector Rated Capacity 1.8 kip, the page's opening figures; on the metric page, 50 kN and 8 kN give 7 connector units. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Total Joint Load | `totalLoad` | 50 kN | 11.2404 kip | n, kn, lbf, kip; range 1000–500000 N |
| Per-Connector Rated Capacity | `perConnectorCapacity` | 8 kN | 1.79847 kip | n, kn, lbf, kip; range 500–50000 N |

- **Total Joint Load**: The total design load the joint must transfer.
- **Per-Connector Rated Capacity**: The rated capacity of a single connector, from the NDS Chapter 12 tables or manufacturer data.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Connector units needed** | 7 connector units |

### US customary

| Result | Value |
|---|---|
| **Connector units needed** | 7 connector units |

- Confidence: medium.

## How it is worked out

This is a simple division of total load by your entered per-connector capacity — make sure that capacity comes from the actual NDS Chapter 12 table value (adjusted for species, thickness, and edge distance) or the manufacturer's rated data, not an assumed number.

The method, derived in full:

- [Fastener Capacity and the Failure Mode That Governs](https://craftquantities.com/methodology/fastener-capacity-modes/): Why an anchor's capacity is the smallest of several modes rather than one number, why concrete breakout grows with embedment to the power of one and a half, and why hole cleaning is the largest variable on site.

What this calculation does not cover:

- Group action is not applied. The NDS group action factor Cg falls as more connectors are added to a row, so the single-connector capacity you looked up is only valid for the number of connectors you assumed when you looked it up — which may not be the number this page returns. Re-check the tabulated value against the count and iterate until the two agree.
- Direction of load relative to grain is ignored. Split-ring and shear-plate design values differ parallel and perpendicular to grain, and a load at an angle has to be interpolated between them. This calculation divides one number by another with no knowledge of your joint geometry, so a parallel-to-grain capacity applied to an angled or cross-grain load overstates the joint.
- Nothing here checks that the connectors physically fit. End distance, edge distance, spacing along and across the row, the member thickness and width needed to seat a ring or plate, and whether the returned count fits on the contact face at all are all outside this calculation.
- This is a connector count, not a connection design, and it does not replace one. The member itself is unchecked: net section at the connector groove, tension or compression capacity of the wood, row and group tear-out, and shear and bearing on the bolt through the ring or plate are separate calculations. A split ring cuts a groove that removes cross-section, so the member can govern before the connectors do.
- Service and installation conditions are not applied. Wet service, elevated temperature, preservative or fire-retardant treatment, load reversal or cyclic loading, and whether the connector sits in one face or both all change the value you look up — none of them change the division done here, and none are checked.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- NDS timber connector design values (split rings, shear plates) are species- and size-specific tables (NDS Chapter 12) rather than a single formula — this calculator divides your total required joint load by your own connector's rated capacity from that table or the manufacturer's data

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why isn't there a single formula for split-ring or shear-plate capacity?**

NDS Chapter 12 design values for split rings and shear plates are tabulated by connector size, wood species group, member thickness, and edge/end distance rather than derived from one general formula — capacity has to be looked up, not calculated from scratch.

**Does this account for group action or spacing adjustment factors?**

No — this calculator only divides total load by the per-connector capacity you provide. Any NDS adjustment factors (group action, geometry, load duration, etc.) should already be baked into the per-connector capacity value you enter.

**Where do I get the per-connector rated capacity?**

Look it up in the NDS Chapter 12 connector tables for your specific connector size and wood species group, or use the manufacturer's published rated capacity for that product and member configuration.

## Related calculators

- [Truss Plate (MPC) Connector Sizing Calculator](https://craftquantities.com/calculators/materials-quantities/truss-plate-connector-calculator/)
- [Ledger Lag Screw Shear Count Calculator](https://craftquantities.com/calculators/materials-quantities/ledger-lag-screw-count-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/timber-shear-connector-count-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/timber-shear-connector-count-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `timber-shear-connector-count-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/timber-shear-connector-count-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/timber-shear-connector-count-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.