# Timber Fastener Withdrawal Capacity Calculator

> What a nail, screw or lag (coach) screw holds in axial withdrawal, one fastener and the group, with the end-grain rule applied rather than argued about.

Page: https://craftquantities.com/calculators/materials-quantities/timber-fastener-withdrawal-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-08-30, 5 published test vectors.

Withdrawal capacity of the group: 6.81 kips for Fastener Shank Diameter 0.5 in and Penetration Into the Holding Member 3 in, the page's opening figures; on the metric page, 12 mm and 75 mm give 28.6 kN. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Fastener Type | `fastenerType` | Lag screw or coach screw | Lag screw or coach screw | `nail`, `wood_screw`, `lag_screw` |
| Fastener Shank Diameter | `shankDiameter` | 12 mm | 0.5 in | mm, cm, m, in, ft, yd; range 0.002–0.03 m |
| Penetration Into the Holding Member | `penetration` | 75 mm | 3 in | mm, cm, m, in, ft, yd; range 0.01–0.4 m |
| Specific Gravity of the Holding Member (G) | `specificGravity` | 0.5 | 0.5 | range 0.3–0.85 |
| Grain Direction at the Point of Entry | `grainOrientation` | Side grain — driven across the fibres, the normal case | Side grain — driven across the fibres, the normal case | `side`, `end` |
| Wet Service Factor (CM) | `wetServiceFactor` | 1 | 1 | range 0.2–1 |
| Fasteners in the Group (count) | `fastenerCount` | 6 | 6 | range 1–60 |

- **Fastener Type**: Which fastener is resisting the pull, because each has its own published equation.
- **Fastener Shank Diameter**: The unthreaded shank diameter of the fastener, not the diameter over the thread.
- **Penetration Into the Holding Member**: How far the fastener actually enters the member that has to hold it.
- **Specific Gravity of the Holding Member (G)**: The assigned specific gravity of the species the fastener bites into.
- **Grain Direction at the Point of Entry**: Whether the fastener enters across the fibres or straight into the cut end.
- **Wet Service Factor (CM)**: The moisture adjustment your own code table gives for this fastener and this exposure.
- **Fasteners in the Group (count)**: How many fasteners share the pull at this one connection.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Withdrawal capacity of the group** | 28.6 kN |
| Withdrawal capacity of one fastener | 4,763.24 N |
| Withdrawal resistance per unit of penetration | 63,509.82 N/m |
| Fasteners in the group | 6 fasteners |
| Combined reduction applied for grain direction and moisture | 1 factor |

### US customary

| Result | Value |
|---|---|
| **Withdrawal capacity of the group** | 6.81 kips |
| Withdrawal capacity of one fastener | 1,135.21 lbf |
| Withdrawal resistance per unit of penetration | 4,540.84 lbf/ft |
| Fasteners in the group | 6 fasteners |
| Combined reduction applied for grain direction and moisture | 1 factor |

## How it is worked out

Side grain, dry service, and the published reference equation for this fastener applied directly. This is a reference design value: the load duration factor and any temperature factor still have to be applied on top of it.

The working the page shows, in order: Withdrawal capacity of one fastener; Withdrawal resistance per unit of penetration; Fasteners in the group; Combined reduction applied for grain direction and moisture; then withdrawal capacity of the group.

The method, derived in full:

- [Fastener Capacity and the Failure Mode That Governs](https://craftquantities.com/methodology/fastener-capacity-modes/): Why an anchor's capacity is the smallest of several modes rather than one number, why concrete breakout grows with embedment to the power of one and a half, and why hole cleaning is the largest variable on site.

What this calculation does not cover:

- Applies the moisture and end-grain adjustments only. The load duration factor CD, the temperature factor Ct and the toe-nail factor are separate multipliers this page does not apply.
- Reference design values are for smooth-shank fasteners. A ring-shank, screw-shank or proprietary structural screw withdraws considerably better, and its capacity comes from the manufacturer's evaluation report, not from these equations.
- Says nothing about head pull-through, about the side member splitting, or about the fastener's lateral capacity — a hold-down usually fails at one of those before the shank ever pulls out of the timber.
- A rated strap, hanger or hold-down is designed on its own tested capacity with every specified hole filled. Where such a product is used, this calculation is a cross-check on the fasteners, not a substitute for the rating.

A professional must decide:

- Reference design values are for smooth-shank fasteners. A ring-shank, screw-shank or proprietary structural screw withdraws considerably better, and its capacity comes from the manufacturer's evaluation report, not from these equations.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-08-30):

- ANSI/AWC NDS, National Design Specification for Wood Construction, Chapter 12 — reference withdrawal design values W in pounds per inch of penetration: W = 1380·G^2.5·D for nails and spikes, W = 2850·G²·D for wood screws, and W = 1800·G^1.5·D^0.75 for lag screws, with D the shank diameter in inches and G the assigned specific gravity
- ANSI/AWC NDS — the end grain factor Ceg of 0.75 applied to lag screws loaded in withdrawal from end grain, and the rule that withdrawal design values are not permitted for nails and spikes driven into end grain
- ANSI/AWC NDS assigned specific gravities for common structural species combinations — Douglas Fir-Larch 0.50, Southern Pine 0.55, Hem-Fir 0.43, Spruce-Pine-Fir 0.42 — entered here as a value rather than picked from a built-in table, because the assignment belongs to the species combination and grading agency on the stamp
- EN 1995-1-1 Section 8 and EN 14592, Timber fasteners — the European route to the same quantity works from characteristic density and the withdrawal parameter declared for the specific screw, so a screw covered by a European Technical Assessment is designed on its declared value and not on the equations above

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does a nail into end grain come back as zero rather than a small number?**

Because that is what the standard says, and because a small number would be worse than none. The NDS does not permit a withdrawal design value for a nail or spike driven into end grain, so there is no figure to report. Fibres pulled apart along their own length give a capacity that varies enormously with the cut, the moisture and the grain angle, and a plausible-looking number would invite somebody to build on it.

**Is this an allowable value or a factored one?**

Allowable. The NDS withdrawal equations give reference design values in the allowable stress format, so the figure here sits beside an unfactored service load, not a factored one. It still needs the load duration factor for the combination you are checking, and a temperature factor where the connection runs warm. Comparing it against a factored uplift is a mismatch no unit conversion will reconcile.

**Why is there no group reduction when I add more fasteners?**

Because withdrawal does not have one. The group action factor exists for laterally loaded rows, where the fasteners nearest the end of the row take more than their share as the joint slips. A group in withdrawal simply adds, provided each fastener has its full penetration and adequate spacing, and provided the timber around them is not splitting instead.

**My screw has a European Technical Assessment. Should I use this page?**

As a sanity check only. A screw covered by an ETA is designed on the withdrawal parameter declared for that specific product under EN 14592, and that declared value reflects thread form, hardening and surface treatment that no general equation can see. Where a declared value exists, it wins; this page is for the plain nail, wood screw and lag screw the NDS equations were fitted to.

## Related calculators

- [Timber Cross-Grain Shrinkage Calculator](https://craftquantities.com/calculators/materials-quantities/timber-cross-grain-shrinkage-calculator/)
- [Timber Shear Connector Count Calculator](https://craftquantities.com/calculators/materials-quantities/timber-shear-connector-count-calculator/)
- [Wood Load Duration Factor (CD) Adjustment Calculator](https://craftquantities.com/calculators/materials-quantities/wood-load-duration-factor-calculator/)
- [Ledger Lag Screw Shear Count Calculator](https://craftquantities.com/calculators/materials-quantities/ledger-lag-screw-count-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/timber-fastener-withdrawal-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/timber-fastener-withdrawal-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `timber-fastener-withdrawal-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/timber-fastener-withdrawal-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/timber-fastener-withdrawal-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.