# Timber Cross-Grain Shrinkage Calculator

> How far timber moves across the grain between its moisture at fixing and in service, for one member and stacked up a platform-framed building.

Page: https://craftquantities.com/calculators/materials-quantities/timber-cross-grain-shrinkage-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-08-30, 3 published test vectors.

Cross-grain movement at one floor level: 0.275 in for Depth of Cross-Grain Timber at One Floor Level 11.75 in, the page's opening figures; on the metric page, 300 mm gives 7.02 mm. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Depth of Cross-Grain Timber at One Floor Level | `crossGrainDepth` | 300 mm | 11.75 in | mm, cm, m, in, ft, yd; range 0.02–1.5 m |
| Moisture Content at Fixing, per cent | `moistureAtFixing` | 19 | 19 | range 5–28 |
| Equilibrium Moisture Content in Service, per cent | `serviceMoisture` | 10 | 10 | range 4–25 |
| Dimensional Change Coefficient | `shrinkageCoefficient` | 0.0026 | 0.0026 | range 0.0008–0.0045 |
| Floor Levels Stacked Above One Another (count) | `floorLevels` | 3 | 3 | range 1–12 |

- **Depth of Cross-Grain Timber at One Floor Level**: The summed depth of horizontally laid timber the load path passes through at one level.
- **Moisture Content at Fixing, per cent**: The meter reading taken on the timber at the moment it was fixed in place.
- **Equilibrium Moisture Content in Service, per cent**: Where the timber will settle once the building is finished and running.
- **Dimensional Change Coefficient**: The fraction of its depth the timber moves for each single point of moisture change.
- **Floor Levels Stacked Above One Another (count)**: How many platform-framed levels the movement accumulates through.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Cross-grain movement at one floor level** | 7.02 mm |
| Accumulated movement over all floor levels | 21.06 mm |
| Depth remaining once the movement has happened | 292.98 mm |
| Movement for a single point of moisture change | 0.78 mm |
| Change in moisture content | 9 % |
| Proportion of the depth lost | 2.34 % |

### US customary

| Result | Value |
|---|---|
| **Cross-grain movement at one floor level** | 0.275 in |
| Accumulated movement over all floor levels | 0.82 in |
| Depth remaining once the movement has happened | 11.48 in |
| Movement for a single point of moisture change | 0.03 in |
| Change in moisture content | 9 % |
| Proportion of the depth lost | 2.34 % |

## How it is worked out

Straight arithmetic on the coefficient and the moisture change entered. The movement is across the grain; along the grain the same change moves the timber by a small fraction of this and is normally ignored.

The working the page shows, in order: Accumulated movement over all floor levels; Depth remaining once the movement has happened; Movement for a single point of moisture change; Change in moisture content; Proportion of the depth lost; then cross-grain movement at one floor level.

The method, derived in full:

- [Thermal and Moisture Movement, and the Joint That Absorbs It](https://craftquantities.com/methodology/movement-and-joints/): Why a restrained element's stress is the same whatever its length, why a clay brick outer leaf and a block inner leaf move in opposite directions, and why a joint's width is set by the sealant rather than by the movement.

What this calculation does not cover:

- Movement across the grain only. Timber moves along the grain by a small fraction of this, and a long member's length is effectively stable.
- Says nothing about whether the movement will be RESTRAINED. A member free to shrink simply shrinks; the split the guide describes happens when two rigid fixing lines hold a deep section apart while it tries to move, and that is a detailing question this arithmetic cannot answer.
- Uses one coefficient for the whole stack. Where the plates, the rim and the joists are different species or different sawing patterns, run them separately and add the results.
- Ignores creep, mechano-sorptive movement under sustained load, and any moisture cycling. A detail that dries, wets and dries again does not simply return to where it started.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-08-30):

- USDA Forest Products Laboratory, Wood Handbook: Wood as an Engineering Material (General Technical Report FPL-GTR-190), Chapter 4 — the dimensional change coefficient method, in which the change in a dimension equals the dimension multiplied by the coefficient and by the change in moisture content, valid below the fibre saturation point
- EN 1995-1-1 (Eurocode 5) service classes — service class 1 describes an environment in which the average moisture content of most softwoods will not exceed 12 per cent, and service class 2 one in which it will not exceed 20 per cent; those are the end points this calculation runs to
- EN 335, Durability of wood and wood-based products — Use classes, which describe the exposure a detail will actually see and therefore the moisture the timber in it will reach
- RULE OF THUMB, stated as one: platform-framed shortening is estimated by summing the depth of horizontally grained timber at each floor — sole plate, rim board or joist depth, and top plates — because those pieces shrink across their depth while the studs between them barely move at all

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why does the calculation ignore the studs?**

Because they barely move. Timber shrinks across the grain by one to two orders of magnitude more than it does along it, and a stud stands with its grain vertical, so its length is effectively stable while everything laid flat at each floor loses depth. That is also why the number here grows with the number of floors rather than with the height of the building.

**Where does the split the timber guide describes come from?**

From restraint, not from the movement itself. A member free to shrink shrinks and nothing happens. Bolt a deep section top and bottom to a rigid plate and the two fixing lines hold it apart while the wood between them tries to get shorter, so the tension goes across the grain, which is the weakest direction there is, and it opens a split. Concentrating the fasteners on one line, or slotting the secondary holes, gives the movement somewhere to go.

**Should I use the tangential or the radial coefficient?**

Tangential unless you know the member is quarter-sawn. Flat-sawn material presents its tangential face to the depth being measured and moves roughly half as much again as quarter-sawn material does. Most structural framing is neither cleanly one nor the other, and taking the tangential figure keeps the estimate on the safe side of the gap you are about to detail.

**How much movement is enough to matter?**

More than the movement allowance built into whatever is fixed across it, which is the number to compare against rather than a general tolerance. A few millimetres over a whole building is nothing to a timber-clad wall that was detailed with open joints, and it is a cracked panel, a jammed door or a sheared service connection where something rigid was fixed to the frame at two levels.

## Related calculators

- [Timber Fastener Withdrawal Capacity Calculator](https://craftquantities.com/calculators/materials-quantities/timber-fastener-withdrawal-calculator/)
- [Timber Beam Bending Stress Calculator](https://craftquantities.com/calculators/materials-quantities/timber-beam-bending-stress-calculator/)
- [Timber Beam Notch Reduction Factor Calculator](https://craftquantities.com/calculators/materials-quantities/timber-notch-reduction-calculator/)
- [Soil Swell & Shrinkage Haul Volume Calculator](https://craftquantities.com/calculators/materials-quantities/soil-swell-shrinkage-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/timber-cross-grain-shrinkage-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/timber-cross-grain-shrinkage-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `timber-cross-grain-shrinkage-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/timber-cross-grain-shrinkage-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/timber-cross-grain-shrinkage-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.