# Shallow Foundation Bearing Capacity Calculator (Vesic Factors)

> Estimate a shallow strip footing's ultimate bearing capacity from the general equation, with the Prandtl-Reissner and Vesic factors used today.

Page: https://craftquantities.com/calculators/materials-quantities/terzaghi-bearing-capacity-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Ultimate bearing capacity: 22,300 psf for Soil Cohesion 208.85 psf, the page's opening figures; on the metric page, 10 kPa gives 1,070 kN/m². Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Soil Cohesion (c) | `cohesion` | 10 kPa | 208.854 psf | pa, kpa, mpa, psi, psf, in_wc; range 0–200000 Pa |
| Friction Angle (φ, degrees) | `frictionAngle` | 30 | 30 | range 0–45 |
| Overburden (Surcharge) Pressure (q) | `surchargePressure` | 20 kPa | 417.709 psf | pa, kpa, mpa, psi, psf, in_wc; range 0–200000 Pa |
| Soil Unit Weight (γ) | `soilUnitWeight` | 18 kN/m³ | 114.586 pcf | knm3, pcf_weight; range 14–22 kN/m³ |
| Footing Width (B) | `footingWidth` | 2 m | 6.5 ft | mm, cm, m, in, ft, yd; range 0.01–10 m |

- **Soil Cohesion (c)**: The soil's cohesion.
- **Friction Angle (φ, degrees)**: The soil's angle of internal friction.
- **Overburden (Surcharge) Pressure (q)**: The overburden pressure at the footing's base level.
- **Soil Unit Weight (γ)**: The soil's unit weight below the footing.
- **Footing Width (B)**: The footing's width.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Ultimate bearing capacity** | 1,070 kN/m² |
| Nc | 30.14 |
| Nq | 18.4 |
| Nγ | 22.4 |

### US customary

| Result | Value |
|---|---|
| **Ultimate bearing capacity** | 22,300 psf |
| Nc | 30.14 |
| Nq | 18.4 |
| Nγ | 22.4 |

- Confidence: medium.

## How it is worked out

This gives ULTIMATE bearing capacity — a real design divides this by a factor of safety (commonly 2.5-3.0) to get the allowable bearing pressure, and applies shape/depth/inclination correction factors for non-strip footings, which this simplified strip-footing calculator omits.

The working the page shows, in order: Nc; Nq; Nγ; then ultimate bearing capacity.

The method, derived in full:

- [Bearing Capacity, and How a Load Spreads Into What Carries It](https://craftquantities.com/methodology/bearing-and-load-spread/): Why the allowable pressure under a footing is usually set by settlement rather than by strength, why a wider footing settles more at the same pressure, and why timber bearing is limited by the weakest direction of the grain.

What this calculation does not cover:

- Ultimate capacity at shear failure, with no settlement check. On sand and on stiff clay the working pressure is usually set by total and differential settlement rather than by bearing failure, so a footing can clear this figure and still move more than the structure above it will tolerate.
- Groundwater is not in the model. There is no water table input, and when water stands at or above founding level both the surcharge term and the 0.5×γ×B×Nγ term have to be built from effective stresses — the unit weight field will not even accept a submerged unit weight, its floor being 14 kN/m³ (89 pcf). Reduce q and γ yourself before entering them, or the capacity reads high.
- Strip footings under a vertical, centrally applied load only. No shape, depth, load-inclination or ground/base-slope factors are applied, so a square or rectangular pad, a circular base, a raft or an eccentrically loaded footing falls outside it; eccentricity also calls for the effective-width reduction B − 2e, which this does not do.
- General shear failure is assumed at every friction angle. Loose sands and soft compressible clays fail by local or punching shear, where these factors overstate capacity, and no reduction to c or tanφ is made for it.
- One uniform soil, taken to extend through the whole failure wedge — roughly one to two footing widths below the base. Layering is invisible to it: a soft stratum under a firm crust, or fill over natural ground, returns the crust's capacity. This is a screening figure against parameters someone else measured, not a foundation design, and it does not replace a site investigation or an engineer's allowable bearing pressure.

A professional must decide:

- One uniform soil, taken to extend through the whole failure wedge — roughly one to two footing widths below the base. Layering is invisible to it: a soft stratum under a firm crust, or fill over natural ground, returns the crust's capacity.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- General bearing capacity equation: qu = c×Nc + q×Nq + 0.5×γ×B×Nγ, with the Prandtl–Reissner factors Nq = e^(π·tanφ)·tan²(45+φ/2) and Nc = (Nq−1)·cotφ (Nc = 5.14 at φ=0), and Vesic's Nγ = 2(Nq+1)·tanφ
- These are the factors Meyerhof, Hansen and Vesic use, not Terzaghi's own 1943 factors. Terzaghi's run higher — roughly 10–22% across this calculator's friction-angle range — so a capacity from this page is the more conservative of the two

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What is 'ultimate' bearing capacity vs. 'allowable'?**

Ultimate bearing capacity is the theoretical failure load; allowable bearing pressure divides this by a safety factor (typically 2.5-3.0) to keep the foundation well within safe working stress — the allowable value is what you'd actually design against.

**Why does this formula only apply to strip footings?**

Terzaghi's original equation was derived for a continuous (strip) footing — square, rectangular, or circular footings need additional shape correction factors (from Meyerhof, Hansen, or Vesic's extended methods) for accurate results.

**What if my soil has both cohesion and friction?**

That's exactly what this formula handles — 'c-φ' soils (like stiff clays or silty sands) use all three terms together, unlike purely cohesive (φ=0) or purely granular (c=0) special cases.

## Related calculators

- [Footing Soil Bearing Pressure Checker](https://craftquantities.com/calculators/materials-quantities/footing-bearing-pressure-calculator/)
- [Isolated Spread Footing Sizing Calculator](https://craftquantities.com/calculators/materials-quantities/spread-footing-sizing-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/terzaghi-bearing-capacity-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/terzaghi-bearing-capacity-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `terzaghi-bearing-capacity-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/terzaghi-bearing-capacity-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/terzaghi-bearing-capacity-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.