# Needle and Prop Load Calculator (Temporary Masonry Support)

> What each needle and prop holds while a wall is supported over a new opening, and the sole plate area each prop needs for the floor beneath to take it.

Page: https://craftquantities.com/calculators/materials-quantities/temporary-needle-prop-load-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-08-30, 3 published test vectors.

Load carried by each needle: 3.63 kips for Height of Masonry Above the Opening 8 ft, Wall Thickness 8.5 in and Masonry Unit Weight 124.86 pcf, the page's opening figures; on the metric page, 2.4 m, 215 mm and 2000 kg/m³ give 15.9 kN. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Height of Masonry Above the Opening | `masonryHeightAbove` | 2.4 m | 8 ft | mm, cm, m, in, ft, yd; range 0.3–8 m |
| Wall Thickness | `wallThickness` | 215 mm | 8.5 in | mm, cm, m, in, ft, yd; range 0.075–0.6 m |
| Masonry Unit Weight | `masonryDensity` | 2000 kg/m³ | 124.856 pcf | kgm3, pcf, lbyd3; range 1000–2600 kg/m³ |
| Opening Width | `openingWidth` | 3 m | 10 ft | mm, cm, m, in, ft, yd; range 0.5–8 m |
| Needle Spacing | `needleSpacing` | 0.9 m | 3 ft | mm, cm, m, in, ft, yd; range 0.3–2 m |
| Floor Load Bearing on the Wall | `floorPressure` | 3 kPa | 62.6563 psf | pa, kpa, mpa, psi, psf, in_wc; range 0–20000 Pa |
| Floor Tributary Width onto This Wall | `floorTributaryWidth` | 2.5 m | 8 ft | mm, cm, m, in, ft, yd; range 0–8 m |
| Allowable Bearing Pressure Under the Sole Plate | `allowableBearingPressure` | 100 kPa | 2088.54 psf | pa, kpa, mpa, psi, psf, in_wc; range 25000–500000 Pa |

- **Height of Masonry Above the Opening**: From the head of the new opening up to the top of the wall, or to the next support.
- **Wall Thickness**: The thickness of the masonry being held, excluding any leaf that is not being supported.
- **Masonry Unit Weight**: The bulk unit weight of the wall being held, mortar included.
- **Opening Width**: The clear width of the opening being formed under the supported wall.
- **Needle Spacing**: Centre-to-centre spacing of the needles through the wall.
- **Floor Load Bearing on the Wall**: The combined permanent and imposed load of any floor framing into this wall.
- **Floor Tributary Width onto This Wall**: How much floor this wall carries — normally half the span of the floor either side of it.
- **Allowable Bearing Pressure Under the Sole Plate**: What the surface the props stand on can take without settling or punching through.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Load carried by each needle** | 15.9 kN |
| Load carried by each prop | 7.93 kN |
| Needles across the opening | 4 needles |
| Combined line load along the wall | 17.62 kN/m |
| Masonry share of that line load | 10.12 kN/m |
| Floor share of that line load | 7.5 kN/m |
| Sole plate bearing area required beneath each prop | 0.08 m² |

### US customary

| Result | Value |
|---|---|
| **Load carried by each needle** | 3.63 kips |
| Load carried by each prop | 1.81 kips |
| Needles across the opening | 4 needles |
| Combined line load along the wall | 1,208.77 lbf/ft |
| Masonry share of that line load | 707.52 lbf/ft |
| Floor share of that line load | 501.25 lbf/ft |
| Sole plate bearing area required beneath each prop | 0.87 sq ft |

- Confidence: medium.

## How it is worked out

Needling and propping is temporary works. This gives the loads to design to; it does not select the props, check them for buckling at their extended length, or confirm that what the props stand on can take them. All three belong to a temporary works designer.

The working the page shows, in order: Load carried by each prop; Needles across the opening; Combined line load along the wall; Masonry share of that line load; Floor share of that line load; Sole plate bearing area required beneath each prop; then load carried by each needle.

The method, derived in full:

- [Temporary Works: Slings, Wind, Battering and Haul Cycles](https://craftquantities.com/methodology/temporary-works-and-site-safety/): Why a shallow sling angle doubles the tension in every leg, why a sheeted scaffold carries an order more wind than an open one, and why adding trucks to a short haul achieves nothing.

What this calculation does not cover:

- Takes the full rectangle of masonry above the opening. That is deliberately conservative — arching can carry some of it away, but only in sound masonry with enough height and no nearby opening.
- Does not check the prop itself. A prop's safe working load falls sharply with extension and with any eccentricity at the head, and the manufacturer's chart is the only place that answer lives.
- Does not check the needle. Bending, shear and bearing on the masonry at the needle hole all need sizing against the load this page gives.
- Assumes props each side of the wall share equally. A single-sided scheme, or props at different extensions, does not.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-08-30):

- Statics of a propped needle: the masonry above the opening is taken as a full rectangle of wall (height above opening × thickness × unit weight), any floor bearing on the wall is added as a line load, and the result is shared between needles on their spacing as a tributary width
- BS 5975, Code of practice for temporary works procedures and the permissible stress design of falsework — needling and propping is temporary works and requires a designer, a design brief and a check before any load is transferred
- The full rectangle above the opening is the CONSERVATIVE assumption and is used deliberately. Arching action in masonry can carry part of that weight around the opening, but it cannot be relied on where the wall is short above the opening, where another opening is nearby, or where the mortar is poor
- Masonry unit weight is entered by the user. The default of 2000 kg/m³ (about 125 pcf) sits inside the range normally taken for clay brickwork and dense concrete blockwork; lightweight blockwork is far lower and must be entered as such

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why assume the whole rectangle of masonry rather than a triangle?**

Because arching is a favour the wall may or may not do you. Sound masonry with plenty of height above an opening will arch and shed load to either side, and taking a triangle would be reasonable there. Old lime mortar, a wall only a course or two deep above the head, or another opening within the arch's reach all break that assumption — and a propping scheme is not the place to find out which case you are in.

**Is the load per prop really half the load per needle?**

Only if there is a prop each side of the wall and both are at the same extension on the same bearing. That is the standard arrangement and it is what this page assumes. A single-sided scheme, or a needle propped off a scaffold on one side and a slab on the other, shares the load quite differently and needs the split worked out explicitly.

**Why does the sole plate area matter so much?**

Because a prop concentrates several tonnes into a base plate the size of a paperback, and most floors will not take that. The sole plate spreads it. Get it wrong and the prop punches into a screed, settles into hardcore, or splits a floorboard — and every millimetre it drops is a millimetre the wall above comes down with it.

**Do I still need a temporary works designer if the numbers look small?**

Yes. The load is only one part of it: prop selection at the extension you need, restraint of the wall above out of plane, the sequence of transferring load onto the needles and off them again, and the check that the thing under the props can take them. A small number does not make a scheme, and the collapses happen during the transfer rather than under the peak load.

## Related calculators

- [Ridge Beam Tributary Load Calculator](https://craftquantities.com/calculators/materials-quantities/ridge-beam-tributary-load-calculator/)
- [Structural Steel Beam Camber Calculator](https://craftquantities.com/calculators/materials-quantities/steel-beam-camber-calculator/)
- [Masonry Bond Beam Rebar Calculator](https://craftquantities.com/calculators/materials-quantities/masonry-bond-beam-rebar-calculator/)
- [Floor Beam Vibration Natural Frequency Calculator](https://craftquantities.com/calculators/materials-quantities/floor-vibration-frequency-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/temporary-needle-prop-load-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/temporary-needle-prop-load-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `temporary-needle-prop-load-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/temporary-needle-prop-load-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/temporary-needle-prop-load-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.