# Fillet Weld Shear Capacity Calculator

> Calculate a fillet weld's nominal shear capacity from its leg size, electrode strength, and length.

Page: https://craftquantities.com/calculators/materials-quantities/structural-steel-weld-shear-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Nominal weld shear capacity: 71.4 kips for Fillet Weld Leg Size 0.31 in and Total Weld Length 7.75 in, the page's opening figures; on the metric page, 8 mm and 200 mm give 328 kN. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Fillet Weld Leg Size | `legSize` | 8 mm | 0.31 in | mm, cm, m, in, ft, yd; range 0.003–0.025 m |
| Electrode | `electrodeStrength` | E70XX (FEXX = 483 MPa / 70 ksi) | E70XX (FEXX = 483 MPa / 70 ksi) | `483`, `552` |
| Total Weld Length | `weldLength` | 200 mm | 7.75 in | mm, cm, m, in, ft, yd; range 0.01–2 m |

- **Fillet Weld Leg Size**: The nominal leg size of the equal-leg fillet weld.
- **Electrode**: The electrode classification, which sets the weld metal's classification strength FEXX.
- **Total Weld Length**: The total effective length of the weld seam.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Nominal weld shear capacity** | 328 kN |
| Effective throat thickness | 5.66 mm |
| Capacity per unit length of weld | 1.64 kN/mm |

### US customary

| Result | Value |
|---|---|
| **Nominal weld shear capacity** | 71.4 kips |
| Effective throat thickness | 0.22 in |
| Capacity per unit length of weld | 9.21 kips/in |

- Confidence: medium.

## How it is worked out

This is the NOMINAL weld strength Rn from AISC 360 §J2.4. It is not a usable design capacity: apply φ = 0.75 for LRFD, or divide by Ω = 2.00 for ASD, and check the connected base metal separately — the base metal, not the weld, governs many joints.

The working the page shows, in order: Effective throat thickness; Capacity per unit length of weld; then nominal weld shear capacity.

The method, derived in full:

- [Fastener Capacity and the Failure Mode That Governs](https://craftquantities.com/methodology/fastener-capacity-modes/): Why an anchor's capacity is the smallest of several modes rather than one number, why concrete breakout grows with embedment to the power of one and a half, and why hole cleaning is the largest variable on site.

What this calculation does not cover:

- 0.60 FEXX is the base case, for a weld loaded parallel to its own axis. AISC J2.4 permits a directional increase for welds loaded at an angle to their length — up to 1.5 times for a fillet loaded transverse to it — so this reads conservative for an end weld and exact for a side weld, and a group containing both has to be handled by the code's combination rule rather than by adding the two lengths together.
- Length is taken as fully effective however long it runs. For end-loaded fillet welds longer than about 100 times the leg size AISC applies a reduction factor, because stress along a long lap is not uniform and the far end does less work than the near end; below four times the leg size the effective length is cut back instead. A long lap weld does not deliver capacity in proportion to its length.
- The leg size is accepted without any of the rules that bound it. AISC Table J2.4 sets a minimum leg by the thickness of the thicker part joined, so the weld cools slowly enough not to crack, and a weld run along a plate edge is capped at the plate thickness — less 1/16 in (1.6 mm) on material 1/4 in (6 mm) and over — so the edge is not melted away. A capacity computed from a leg outside those bounds describes a weld that will not be accepted.
- The result is a group total, and it assumes the load passes through the group's centroid. Where it does not — a bracket, a shear tab, a bracing gusset — the weld carries torsion on top of direct shear, the far corner reaches its limit while the rest is barely stressed, and the capacity from an instantaneous-centre analysis falls well below this length × strength product.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- AISC 360 §J2.4 (Table J2.5): nominal weld strength Rn = 0.60×FEXX×Awe, where the effective throat Awe uses te = 0.707×leg size for an equal-leg fillet weld — consistent with AWS D1.1 Table 2.3

The site's pages for the documents these name:

- [AISC 360](https://craftquantities.com/standards/aisc/aisc-360/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is the effective throat 0.707 times the leg size?**

For an equal-leg fillet weld, the effective throat is the shortest distance from the root to the weld face, which geometrically works out to 0.707 (that is, cos 45°) times the leg size, per AISC 360 and AWS D1.1.

**What's the difference between E70XX and E80XX electrodes?**

The number denotes the electrode's classification strength FEXX — E70XX has FEXX = 483 MPa (70 ksi) and E80XX has FEXX = 552 MPa (80 ksi); a higher-strength electrode gives more shear capacity for the same weld size.

**Does this include the base metal shear check?**

No — this calculates only the nominal shear capacity of the weld metal itself (AISC 360 §J2.4). The connected base metal must also be checked for shear rupture along the fusion faces, which can govern for thinner connected material.

## Related calculators

- [High-Strength Structural Bolt Torque Calculator (ASTM F3125)](https://craftquantities.com/calculators/materials-quantities/structural-bolt-torque-calculator/)
- [Steel Moment Connection Bolt Count Calculator](https://craftquantities.com/calculators/materials-quantities/steel-moment-connection-bolt-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/structural-steel-weld-shear-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/structural-steel-weld-shear-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `structural-steel-weld-shear-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/structural-steel-weld-shear-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/structural-steel-weld-shear-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.