# Steel Stair Stringer Bolt Hole Spacing Calculator

> Calculate how many evenly-spaced bolt holes are needed along a steel stair stringer's length.

Page: https://craftquantities.com/calculators/materials-quantities/steel-stringer-bolt-hole-spacing-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-02, 2 published test vectors.

Bolt holes needed: 12 holes for Stringer Length 16.5 ft and Maximum Hole Spacing 18 in, the page's opening figures; on the metric page, 5 m and 450 mm give 13 holes. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Stringer Length | `stringerLength` | 5 m | 16.5 ft | mm, cm, m, in, ft, yd; range 0.01–15 m |
| Maximum Hole Spacing | `maxHoleSpacing` | 450 mm | 18 in | mm, cm, m, in, ft, yd; range 0.01–1.5 m |

- **Stringer Length**: The overall length of the stair stringer along its slope.
- **Maximum Hole Spacing**: The maximum allowed spacing between adjacent bolt holes.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Bolt holes needed** | 13 holes |
| Bays between holes | 12 |
| Hole pitch, as drilled | 0.42 m |

### US customary

| Result | Value |
|---|---|
| **Bolt holes needed** | 12 holes |
| Bays between holes | 11 |
| Hole pitch, as drilled | 1.5 ft |

## How it is worked out

The working the page shows, in order: Bays between holes; Hole pitch, as drilled; then bolt holes needed.

The method, derived in full:

- [Fastener Schedules, Supports and Counting Over a Grid](https://craftquantities.com/methodology/fastener-schedules-and-grid-counts/): Why a fixing count is never area divided by spacing, why the edges of a panel supply more fasteners than its middle, and why the tighter schedule at a roof corner is a requirement rather than caution.

What this calculation does not cover:

- The pitch above is the one to drill from, and it is not the maximum you typed: because the bays are rounded up, a 5 m (16 ft) stringer at a 0.45 m (1.5 ft) maximum is 12 bays at about 417 mm (16 in). What the pitch still assumes is that the run is the whole stringer, end to end — see the end distance below, which shortens it.
- The holes are spread across the whole length entered, which puts the first and last hole exactly on the two cut ends of the stringer. A bolt cannot sit on the end of a member: steel codes set a minimum end distance from the hole centre to the cut edge, normally expressed as a multiple of the bolt diameter or hole size, and the figure is jurisdictional. Set the end holes in by that distance and lay the remaining bays out over what is left.
- The layout is a single evenly-spaced line of holes along one gauge line. Staggered patterns and a second or third bolt row across the web or flange are outside it. For a detail with more than one row, multiply the count by the number of rows and check the cross-wise gauge separately.
- Drilling the holes removes material from a member that is usually working in bending, and this calculation says nothing about the stringer that is left. Net-section capacity along the drilled line and tear-out between adjacent holes are structural checks the count does not touch.

A professional must decide:

- Drilling the holes removes material from a member that is usually working in bending, and this calculation says nothing about the stringer that is left. Net-section capacity along the drilled line and tear-out between adjacent holes are structural checks the count does not touch.

## Sources

As the calculator cites them (sources checked 2026-09-02):

- Bolt hole count = ceil(stringer length ÷ maximum hole spacing) + 1, the standard method for laying out evenly-spaced connection points along a structural member

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**Why is 1 added to the ceiling of length divided by spacing?**

Evenly-spaced holes need one more hole than the number of gaps between them — for example, 4 equal segments along the stringer require 5 holes: one at each end plus 3 in between.

**Where does the maximum hole spacing come from?**

It should come from your connection design — bolt shear/bearing capacity, edge distance, and gauge requirements — or your project specification. This calculator only lays out evenly-spaced holes within whatever maximum spacing you enter.

**Does this check bolt capacity or edge distance requirements?**

No — this only computes hole count from stringer length and maximum spacing. Connection capacity, edge distance, and gauge requirements must be checked separately as part of the connection design.

## Related calculators

- [Structural Steel Stair Stringer Length Calculator](https://craftquantities.com/calculators/materials-quantities/steel-stair-stringer-length-calculator/)
- [Steel Moment Connection Bolt Count Calculator](https://craftquantities.com/calculators/materials-quantities/steel-moment-connection-bolt-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/steel-stringer-bolt-hole-spacing-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/steel-stringer-bolt-hole-spacing-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `steel-stringer-bolt-hole-spacing-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/steel-stringer-bolt-hole-spacing-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/steel-stringer-bolt-hole-spacing-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.