# Steel Girder Lateral-Torsional Buckling Limit (Lp) Calculator

> Calculate the maximum unbraced length (Lp) within which a steel girder retains full plastic moment capacity.

Page: https://craftquantities.com/calculators/materials-quantities/steel-girder-ltb-limit-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.1, sources checked 2026-09-06, 2 published test vectors.

Limiting unbraced length (Lp): 5.3 ft for Minor-Axis Radius of Gyration ry 1.5 in, Steel Yield Strength Fy 50038.02 psi and Modulus of Elasticity E 29007547.55 psi, the page's opening figures; on the metric page, 40 mm, 345 MPa and 200000 MPa give 1.7 m. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Minor-Axis Radius of Gyration ry | `radiusOfGyrationY` | 40 mm | 1.5 in | mm, cm, m, in, ft, yd; range 0.01–0.15 m |
| Steel Yield Strength Fy | `yieldStrength` | 345 MPa | 50038 psi | pa, kpa, mpa, psi, psf, in_wc; range 200000000–700000000 Pa |
| Modulus of Elasticity E | `elasticModulus` | 200000 MPa | 29007500 psi | pa, kpa, mpa, psi, psf, in_wc; range 190000000000–210000000000 Pa |

- **Minor-Axis Radius of Gyration ry**: The section's radius of gyration about its minor (weak) axis, from the shape tables.
- **Steel Yield Strength Fy**: The girder steel's specified minimum yield strength.
- **Modulus of Elasticity E**: The steel's modulus of elasticity — 200,000 MPa (29,000,000 psi) is standard for structural steel.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Limiting unbraced length (Lp)** | 1.7 m |

### US customary

| Result | Value |
|---|---|
| **Limiting unbraced length (Lp)** | 5.3 ft |

- Confidence: medium.

## How it is worked out

This checks only whether your unbraced length is within Lp (full plastic capacity retained). It is NOT a full moment capacity calculator — once the unbraced length exceeds Lp, the actual reduced capacity requires Lr, Cb, Fcr, and Sx per AISC 360 Eqs. F2-2 through F2-6, which a structural engineer should evaluate.

The method, derived in full:

- [Section Capacity: Bending, Axial, Shear, and Which One Gives First](https://craftquantities.com/methodology/section-capacity/): Why depth is worth four times what width is in bending, why reinforced concrete is deliberately designed to fail in the steel rather than the concrete, and why a notch removes far more strength than material.

What this calculation does not cover:

- Lp is a property of the section and the grade — the only inputs are ry and Fy — so it is a yardstick, not a verdict. What it is compared against is Lb, the distance between points that hold the COMPRESSION flange against lateral movement and against twist, and AISC Appendix 6 puts strength and stiffness requirements on those braces. A joist merely bearing on the top flange, or a tie that sways with it, is not a brace point; assume one that does not qualify and the real Lb is double the length checked here.
- Over a support in a continuous beam, and along a cantilever, the moment reverses and the compression flange is the BOTTOM one — which the slab or deck above does not brace at all. The unbraced length that governs there runs between bottom-flange restraints or torsional restraints at the support, and it routinely decides a beam that looks fully braced along its span.
- Lp moves in direct proportion to ry but only with the square root of E/Fy, so the grade barely lengthens it and readily shortens it: substituting Grade 50 steel for Grade 36 cuts Lp by about 15 per cent. Upgrading the steel to gain moment capacity therefore tightens the bracing that capacity depends on, and a bracing layout drawn for the original grade can be too loose for the stronger one.

A professional must decide:

- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-09-06):

- AISC 360 Chapter F, Eq. F2-5: Lp = 1.76×ry×√(E/Fy), the limiting laterally unbraced length below which lateral-torsional buckling does not reduce a doubly-symmetric compact I-shaped member's nominal moment capacity below Mp

The site's pages for the documents these name:

- [AISC 360](https://craftquantities.com/standards/aisc/aisc-360/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**What does it mean if my unbraced length is within Lp?**

That AISC 360 Chapter F treats lateral-torsional buckling as not governing, so the member's nominal moment capacity can reach its full plastic moment Mp, for a doubly-symmetric compact I-shaped member. It applies when the actual laterally unbraced length of the compression flange is at or below the calculated Lp.

**What happens if my unbraced length exceeds Lp?**

This calculator does not evaluate that case. Once the unbraced length exceeds Lp, the nominal moment capacity is reduced and must be calculated using the additional Lr, Cb, Fcr, and Sx terms in AISC 360 Eqs. F2-2 through F2-6 — a structural engineer should perform that check.

**Does this apply to any steel beam shape?**

The Lp formula used here (AISC 360 Eq. F2-5) applies specifically to doubly-symmetric compact I-shaped members and channels bent about their major axis — other shapes (e.g. singly-symmetric or non-compact sections) are governed by different AISC provisions.

## Related calculators

- [Timber Column Euler Buckling Calculator](https://craftquantities.com/calculators/materials-quantities/timber-column-buckling-calculator/)
- [Steel I-Beam Weight-per-Length Calculator](https://craftquantities.com/calculators/materials-quantities/steel-i-beam-weight-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/steel-girder-ltb-limit-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/steel-girder-ltb-limit-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `steel-girder-ltb-limit-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/steel-girder-ltb-limit-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/steel-girder-ltb-limit-calculator/
Craft Quantities: free to read, cite and link to; the pages are not licensed for republication. Quantities only: no prices, no design and no certification.