# Steel and Concrete L- and U-Shaped Stair Calculator (Landings, Channel or Zigzag Stringers, Waist and Bars)

> A steel or cast stair turning on landings: flights, channel or zigzag stringers, tread plates and weight, or concrete, formwork and bars.

Page: https://craftquantities.com/calculators/materials-quantities/steel-concrete-l-u-stair-calculator/ (calculator). This is the page's Markdown copy; the HTML page is the canonical version.

Version 1.0.0, sources checked 2026-11-14, 9 published test vectors.

Risers: 15 risers for Total Rise 9 ft, Riser You Are Aiming For 7.25 in and Going 10.25 in, the page's opening figures; on the metric page, 2.8 m, 185 mm and 260 mm give 16 risers. Sources are cited below.

## Inputs

A length, area or volume is entered with its unit. The page opens on the values below: a metric reader sees the metric column, a US customary reader the other.

| Input | id | Opens at (metric) | Opens at (US customary) | Accepts |
|---|---|---|---|---|
| Material | `material` | Steel stringers | Steel stringers | `steel`, `concrete` |
| Shape | `shape` | L — a quarter landing | L — a quarter landing | `straight`, `l-quarter`, `u-half`, `u-two-quarter` |
| Total Rise (floor to floor) | `totalRise` | 2.8 m | 9 ft | mm, cm, m, in, ft, yd; range 0.3–8 m |
| Riser You Are Aiming For | `targetRiser` | 185 mm | 7.25 in | mm, cm, m, in, ft, yd; range 0.1–0.3 m |
| Going (nosing to nosing) | `going` | 260 mm | 10.25 in | mm, cm, m, in, ft, yd; range 0.15–0.4 m |
| Stair width | `stairWidth` | 1 m | 3.5 ft | mm, cm, m, in, ft, yd; range 0.6–3 m |
| Risers in the first flight | `firstFlight` | 8 | 8 | range 2–30 |
| Risers in the middle flight | `secondFlight` | 3 | 3 | range 2–30 |
| Stringers (steel) | `stringerStyle` | Rolled section (channel or flat) | Rolled section (channel or flat) | `channel`, `zigzag` |
| Stringer section | `section` | PFC 200 × 75 (23.4 kg/m) | PFC 200 × 75 (23.4 kg/m) | `pfc180`, `pfc200`, `pfc230`, `pfc260`, `c8`, `c10`, `c12`, `flat200x10`, `flat250x12` |
| Stringers per flight | `stringerCount` | 2 | 2 | range 2–6 |
| Zigzag strip depth | `zigzagDepth` | 200 mm | 7.75 in | mm, cm, m, in, ft, yd; range 0.1–0.4 m |
| Zigzag plate thickness | `zigzagThickness` | 8 mm | 0.31 in | mm, cm, m, in, ft, yd; range 0.004–0.025 m |
| Tread and landing plate thickness | `plateThickness` | 6 mm | 0.25 in | mm, cm, m, in, ft, yd; range 0.003–0.02 m |
| Nosing | `nosing` | 25 mm | 1 in | mm, cm, m, in, ft, yd; range 0–0.05 m |
| Stringer end allowance | `endAllowance` | 100 mm | 4 in | mm, cm, m, in, ft, yd; range 0–0.3 m |
| Waist (concrete) | `waist` | 150 mm | 6 in | mm, cm, m, in, ft, yd; range 0.08–0.4 m |
| Landing slab thickness | `landingThickness` | 150 mm | 6 in | mm, cm, m, in, ft, yd; range 0.08–0.4 m |
| Cover | `cover` | 25 mm | 1 in | mm, cm, m, in, ft, yd; range 0.015–0.075 m |
| Main bar diameter | `mainBar` | 12 mm | 0.5 in | mm, cm, m, in, ft, yd; range 0.008–0.025 m |
| Main bar spacing | `mainSpacing` | 150 mm | 6 in | mm, cm, m, in, ft, yd; range 0.075–0.4 m |
| Distribution bar diameter | `distBar` | 10 mm | 0.39 in | mm, cm, m, in, ft, yd; range 0.006–0.02 m |
| Distribution bar spacing | `distSpacing` | 250 mm | 9.75 in | mm, cm, m, in, ft, yd; range 0.1–0.5 m |
| Anchorage at each end | `anchorage` | 300 mm | 11.75 in | mm, cm, m, in, ft, yd; range 0–1 m |
| Floor depth at the opening | `floorDepth` | 250 mm | 9.75 in | mm, cm, m, in, ft, yd; range 0–0.6 m |
| Headroom to keep | `headroom` | 2.032 m | 80 in | mm, cm, m, in, ft, yd; range 1.8–2.5 m |
| Allowance (%) | `wastePercent` | 5 | 5 | range 0–20 |
| Code for the readout | `buildingCode` | US — IRC | US — IRC | `irc`, `uk`, `au`, `ca`, `generic` |

- **Material**: Steel flights on stringers, or cast flights and slabs.
- **Shape**: Where the stair turns.
- **Total Rise (floor to floor)**: Finished floor below to finished floor above.
- **Riser You Are Aiming For**: The rise per step you want.
- **Going (nosing to nosing)**: The same on every flight.
- **Stair width**: Width of the flights, and of the landings' sides.
- **Risers in the first flight**: Up to the first landing.
- **Risers in the middle flight**: Between the two quarter landings.
- **Stringers (steel)**: Straight sections, or a strip folded up the steps.
- **Stringer section**: Your section, never chosen or checked here.
- **Stringers per flight**: Two at the sides; a third under a wide stair.
- **Zigzag strip depth**: Width of the folded strip.
- **Zigzag plate thickness**: The plate's thickness.
- **Tread and landing plate thickness**: Checker plate.
- **Nosing**: Tread past its riser.
- **Stringer end allowance**: At each end, for the connection.
- **Waist (concrete)**: Square to the soffit.
- **Landing slab thickness**: The landings' slab.
- **Cover**: To the bars.
- **Main bar diameter**: Along each flight and both ways in the landings.
- **Main bar spacing**: Centre to centre, along the flights and both ways in the landings.
- **Distribution bar diameter**: Across each flight.
- **Distribution bar spacing**: Centre to centre, across each flight.
- **Anchorage at each end**: Main bars carried into the floor or landing.
- **Floor depth at the opening**: Upper floor to the ceiling below.
- **Headroom to keep**: Clear height over the flights.
- **Allowance (%)**: On the steel weight, the concrete and the bars.
- **Code for the readout**: The code the flights, landings and headroom are read against.

`secondFlight` applies only when `shape` is `u-two-quarter`.
`stringerStyle` applies only when `material` is `steel`.
`section` applies only when `stringerStyle` is `channel`.
`stringerCount` applies only when `material` is `steel`.
`zigzagDepth` applies only when `stringerStyle` is `zigzag`.
`zigzagThickness` applies only when `stringerStyle` is `zigzag`.
`plateThickness` applies only when `material` is `steel`.
`endAllowance` applies only when `material` is `steel`.
`waist` applies only when `material` is `concrete`.
`landingThickness` applies only when `material` is `concrete`.
`cover` applies only when `material` is `concrete`.
`mainBar` applies only when `material` is `concrete`.
`mainSpacing` applies only when `material` is `concrete`.
`distBar` applies only when `material` is `concrete`.
`distSpacing` applies only when `material` is `concrete`.
`anchorage` applies only when `material` is `concrete`.

## The answer on the opening values

Worked exactly as the page works it, on the values each system opens on.

### Metric

| Result | Value |
|---|---|
| **Risers** | 16 risers |
| Riser height | 175 mm |
| Flights | 2 flights |
| Landings | 1 landing |
| Steel, all flights and landings, with the allowance | 589.6 kg |
| Longest stringer as cut | 2.5 m |
| Tread plates | 14 plates |
| Floor opening, plan area | 4.16 m² |

### US customary

| Result | Value |
|---|---|
| **Risers** | 15 risers |
| Riser height | 7.2 in |
| Flights | 2 flights |
| Landings | 1 landing |
| Steel, all flights and landings, with the allowance | 1,330.53 lb |
| Longest stringer as cut | 8.33 ft |
| Tread plates | 13 plates |
| Floor opening, plan area | 46.82 sq ft |

## How it is worked out

WITHIN THE LIMITS CHECKED — US IRC 2024: riser height 6.89 in (175 mm) and tread depth 10.24 in (260 mm) are inside the limits this calculator checks. That is not a compliance determination: headroom, handrails, guards, nosings and width are not checked, and the building control body or inspector decides. On this page, headroom is read on its own: the opening is worked out for 2032 mm (80.0 in) of headroom over the pitch line, at or above the 6 ft 8 in (2032 mm) of IRC 2024 R311.7.2; the headroom as built is measured on site. Each landing is 1000 mm (39.37 in) long in the direction of travel, at or over the 36 in (914 mm) of IRC R311.7.6.

The working the page shows, in order: Riser height; Flights; Landings; Steel, all flights and landings, with the allowance; Longest stringer as cut; Tread plates; Floor opening, plan area; then risers.

The method, derived in full:

- [Stair Geometry, Ramps and Guarding](https://craftquantities.com/methodology/stair-geometry-and-guarding/): Why you choose the number of risers rather than their height, why the spread across a whole flight is held to three-eighths of an inch, and why a cable railing has to be checked deflected rather than at rest.

What this calculation does not cover:

- This counts and draws a steel or cast stair that turns; it does not approve it. The riser, going, landings and headroom are read against your code by the L- and U-shaped page's own readout; your building official decides.
- Sections, plate and zigzag thicknesses, waists and bars are your engineer's: entered here, never chosen or checked, and nothing here says a member, a weld, a connection or a bar is adequate.
- A zigzag stringer's length is its folded strip along its line; the bend allowance at each fold is the fabricator's, and the plate it is cut from is the strip's depth wide.
- Landings are flat plates or slabs the stair's width square (a half landing twice the width by once); posts, hangers and the landing's bearing on walls are not counted.

A professional must decide:

- This counts and draws a steel or cast stair that turns; it does not approve it. The riser, going, landings and headroom are read against your code by the L- and U-shaped page's own readout; your building official decides.
- Sections, plate and zigzag thicknesses, waists and bars are your engineer's: entered here, never chosen or checked, and nothing here says a member, a weld, a connection or a bar is adequate.
- Structure: sizes, thicknesses, spans, reinforcement and bearing are a structural engineer's or the building official's decision. This is a quantity, not a design.

## Sources

As the calculator cites them (sources checked 2026-11-14):

- Flights and landings split as this site's L- and U-shaped stair page splits them; each flight worked as its steel stair and concrete stair pages work one (sections from BS EN 10365 and the American standard channel tables, steel at 7850 kg/m³)
- Zigzag stringer: a strip folded riser, tread, riser…, its developed length n x riser + (n - 1) x going and 2n - 1 bends; mass = length x strip depth x thickness x 7850 kg/m³
- US: IRC R311.7.5 (riser at most 7 3/4 in, tread at least 10 in), R311.7.6 (landings at least 36 in in the direction of travel), R311.7.2 (headroom 6 ft 8 in); UK: Approved Document K section 1; Australia: NCC Housing Provisions 11.2.2 and 11.2.5; Canada: NBC 9.8.4 and 9.8.6, as the L- and U-shaped stair page reads them

The site's pages for the documents these name:

- [International Residential Code](https://craftquantities.com/standards/icc/irc/)
- [Approved Documents to the Building Regulations (England)](https://craftquantities.com/standards/uk-gov/uk-approved-documents/)

A code or standard has force only where a jurisdiction has adopted it, usually with local amendments; check what is in force with the authority where you build.

## Questions answered on the page

**How long is a zigzag stair stringer?**

Along its line, every riser and every tread it folds round: n risers and n - 1 goings. Sixteen risers split 8 and 8 at 175 mm on a 260 mm going make each flight's strip 8 x 0.175 + 7 x 0.26 = 3.22 m with 15 bends.

**How much does a steel L-shaped stair weigh?**

Add each flight's stringers, tread plates and brackets to the landing's plate and its frame. A 1 m wide, 2.80 m stair on PFC 200 channels with 6 mm plates comes to about 117 kg of channel and 80 kg of plate a flight, and 141 kg for the landing, before brackets and the allowance.

**Can it work out a cast concrete U-shaped stair?**

Yes: each flight is the cast flight page's section at its own rise, and each landing a slab of your thickness with bars both ways, so the concrete, the formwork and the bars come out for the whole stair.

## Related calculators

- [Steel Stair Calculator (Stringer Cut List, Tread Plates and Weight)](https://craftquantities.com/calculators/materials-quantities/steel-stair-calculator/)
- [Concrete Stair Calculator (Cast Flight: Concrete, Formwork and Rebar)](https://craftquantities.com/calculators/materials-quantities/concrete-stair-calculator/)
- [L-Shaped and U-Shaped Stair Calculator (Landings, Winders, Stringers, Treads and Risers)](https://craftquantities.com/calculators/materials-quantities/landing-stair-calculator/)
- [Winder Stair Calculator (Kite, Balanced and Dancing Winders, Quarter and Half Turns: Each Set Out)](https://craftquantities.com/calculators/materials-quantities/winder-stair-calculator/)

## Run it from a program

- REST: `GET https://api.craftquantities.com/v1/calculate/steel-concrete-l-u-stair-calculator` with each input as a query parameter, a length, area or volume with its unit; `https://api.craftquantities.com/v1/describe/steel-concrete-l-u-stair-calculator` lists the inputs.
- MCP: the `calculate` tool at https://api.craftquantities.com/mcp with `slug` `steel-concrete-l-u-stair-calculator`.
- Definition and test vectors: https://craftquantities.com/api/v1/calculators/steel-concrete-l-u-stair-calculator.json

---
Source: https://craftquantities.com/calculators/materials-quantities/steel-concrete-l-u-stair-calculator/